{"product_id":"h8ps-32b-omron-h8ps-series-cam-positioner","title":"H8PS-32B Omron H8PS Series Cam Positioner","description":"\u003cp\u003eThe \u003cstrong\u003eOmron H8PS-32B\u003c\/strong\u003e serves as the primary \u003cstrong\u003eH8PS\u003c\/strong\u003e Cam Positioner utilized to execute absolute rotary encoder signal evaluation and output switching across high-density motion control platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Number Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eH8PS\u003c\/strong\u003e: Series identifier for panel-mounted electronic cam positioner units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e32\u003c\/strong\u003e: Designates 32-channel discrete NPN transistor output capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Denotes panel-mount construction with 1\/4 DIN outer dimensions (96 x 96 mm) and integrated backlit LCD display.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Electrical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eH8PS-32B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 300 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e96 mm x 96 mm x 67.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage AC\u003c\/td\u003e\n\u003ctd\u003e20.4-26.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eApprox. 15 VA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eForm Factor\u003c\/td\u003e\n\u003ctd\u003e1\/4 DIN (96 x 96 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eLCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003eAbsolute Encoder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eNPN transistor (32 outputs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Motion Bus Processing and Logic Scaling\u003c\/h3\u003e\n\u003cp\u003eInternal signal execution circuits handle high-speed angle decoding from connected absolute encoders to manage elevated I\/O density scaling across complex multi-axis automation cells. Digital comparator logic compares encoder positioning against pre-set angular limits, maintaining backplane bus communication velocity Licences and ensuring persistent firmware flash compatibility for stored program parameters during power interruptions.\u003c\/p\u003e\n\u003ch3\u003ePackage Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron H8PS-32B Cam Positioner Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Panel Mounting Adapter Clamp\u003c\/li\u003e\n\u003cli\u003e1 x Protective Terminal Guard\u003c\/li\u003e\n\u003cli\u003e1 x Panel Waterproof Rubber Gasket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Protocols\u003c\/h3\u003e\n\u003ch4\u003ePanel Cutout Preparation\u003c\/h4\u003e\n\u003cp\u003eCut a standard 1\/4 DIN (92 x 92 mm) square cutout on the control cabinet door. Mount the unit through the front cutout with the waterproof rubber gasket fitted between the bezel and panel door to maintain front sealing.\u003c\/p\u003e\n\u003ch4\u003eEncoder Direction Configuration\u003c\/h4\u003e\n\u003cp\u003eLocate the onboard DIP switches on the housing. Set the designated switch to forward (CW) or reverse (CCW) phase decoding to match the physical rotation direction of the connected absolute encoder.\u003c\/p\u003e\n\u003ch4\u003eTerminal Wiring and Output Grounding\u003c\/h4\u003e\n\u003cp\u003eConnect the 20.4-26.4 VAC supply conductors to the AC power terminals. Wire the 32 discrete NPN open-collector outputs to PLC inputs or relay modules, ensuring proper functional earth (FG) grounding for shield drain wires to prevent noise coupling.\u003c\/p\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow is encoder direction inversion executed on the hardware level?\u003c\/p\u003e\n\u003cp\u003eAn internal DIP switch changes logic decoding phases between Clockwise (CW) and Counter-Clockwise (CCW) without physically swapping input signal leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat internal protection preserves program data when power is lost?\u003c\/p\u003e\n\u003cp\u003eEEPROM non-volatile memory stores all 32-channel ON\/OFF angle settings permanently without reliance on an internal backup battery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the absolute encoder signal cable is severed?\u003c\/p\u003e\n\u003cp\u003eThe positioner logic detects loss of encoder pulses, immediately disables all 32 NPN transistor outputs, and displays an encoder alarm code on the LCD.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 32 NPN transistor outputs be wired directly to inductive loads?\u003c\/p\u003e\n\u003cp\u003eOutputs require external flyback diode protection when switching inductive loads like relay coils to prevent voltage transients from damaging output transistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping the encoder terminal block permitted during operation?\u003c\/p\u003e\n\u003cp\u003eUnplugging or plugging the encoder interface while AC power is applied risks damaging internal logic circuitry and causing output state glitches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding practice prevents signal corruption on the encoder line?\u003c\/p\u003e\n\u003cp\u003eConnect the encoder cable shield to the dedicated Functional Ground (FG) terminal on the positioner end only to avoid ground loop currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat clearance is necessary around the panel housing for thermal safety?\u003c\/p\u003e\n\u003cp\u003eLeave at least 30 mm clear space above and below the rear enclosure inside the cabinet to permit heat dissipation from internal power components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat voltage range is acceptable on the AC power terminals?\u003c\/p\u003e\n\u003cp\u003eThe power circuit operates between 20.4 and 26.4 VAC; supplying voltage outside this tolerance can cause system fault trips or hardware failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306654351533,"sku":"H8PS-32B","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/h8ps-32b_10.jpg?v=1790138821","url":"https:\/\/www.maxwellplc.com\/ru\/products\/h8ps-32b-omron-h8ps-series-cam-positioner","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}