{"product_id":"h7cx-a11s-n-omron-multifunction-counter-tachometer-h7cx-series","title":"H7CX-A11S-N Omron Multifunction Counter\/Tachometer H7CX Series","description":"\u003cp\u003eConfigured for high-speed pulse acquisition and solid-state switching execution in industrial control cabinets, the \u003cb\u003eOmron H7CX-A11S-N\u003c\/b\u003e (\u003cb\u003eH7CX\u003c\/b\u003e Multifunction Counter\/Tachometer) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eDesignator Decoder \u0026amp; Model Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eH7CX\u003c\/b\u003e: Standard DIN 48 x 48 mm digital counter\/tachometer housing base\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eA\u003c\/b\u003e: Standard function specification design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e11\u003c\/b\u003e: Rear interface matching 11-pin circular socket base\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDigits (None)\u003c\/b\u003e: 6-digit negative transmissive LCD display stage (0 to 999999)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSettings (None)\u003c\/b\u003e: 1-stage limit value preset configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eS\u003c\/b\u003e: Solid-state transistor output stage for fast switching speeds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSupply Voltage (None)\u003c\/b\u003e: AC operating power rating of 100 to 240 VAC at 50\/60 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eN\u003c\/b\u003e: Updated internal hardware revision designation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eH7CX-A11S-N\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOmron\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 0.13 kg (Shipping weight: 2.0 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.8 cm x 8.41 cm x 4.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApprox. 9.4 VA max. (100 to 240 VAC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 to 240 VAC (50\/60 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e85% to 110% of rated supply voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Signals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNPN or PNP solid-state \/ contact inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNPN open-collector transistor output (30 VDC max., 100 mA max.)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDisplay System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6-digit negative transmissive LCD with backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExternal Terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11-pin circular socket base\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Input Processing \u0026amp; Bus Architecture Interfacing\u003c\/h3\u003e\n\u003cp\u003eThe internal processing logic continuously measures input frequency and pulse counts at microsecond acquisition rates. Non-volatile EEPROM registers ensure firmware flash compatibility and retain operational parameters during complete supply power outages. Solid-state outputs deliver fast response execution, interfacing cleanly with programmable controllers connected across Profinet \/ EtherNet\/IP deterministic networks via external fieldbus adapters.\u003c\/p\u003e\n\u003ch3\u003ePackaging \u0026amp; Included Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Omron H7CX-A11S-N Digital Counter\/Tachometer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Panel Mount Adapter Clip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Waterproof Rubber Packing Seal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Instruction Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Terminal Wiring Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePanel Cutout Mounting\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003ePunch a standard 45 x 45 mm DIN opening in the panel door. Fit the rubber seal over the front frame, slide the housing into the cutout, and push the rear adapter bracket until it locks firmly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e11-Pin Socket Wiring\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eTerminate field connections to an 11-pin circular base socket (e.g., P2CF-11). Observe terminal polarity for line power connections (100-240 VAC) and solid-state transistor output leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eSignal Line Shielding\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eRun pulse input cables in dedicated metal conduits separated from 3-phase AC power lines and inverter drives. Earth the cable shield at a single cabinet ground point to eliminate noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage range powers the H7CX-A11S-N unit?\u003c\/p\u003e\n\u003cp\u003eThe unit operates on 100 to 240 VAC at 50\/60 Hz, accommodating fluctuations between 85% and 110% of nominal voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control output switching mechanism does this model provide?\u003c\/p\u003e\n\u003cp\u003eIt uses an NPN open-collector transistor output rated for up to 30 VDC and a maximum switching current of 100 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many digits are available on the front LCD panel?\u003c\/p\u003e\n\u003cp\u003eThe unit features a 6-digit backlit negative transmissive LCD supporting a full counting range from 0 to 999999.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are setup parameters and count values stored during AC line power failure?\u003c\/p\u003e\n\u003cp\u003eSettings and current count registers are continuously stored in internal EEPROM memory without requiring battery backup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical terminal layout is used on the back panel?\u003c\/p\u003e\n\u003cp\u003eThe rear interface connects via an 11-pin circular socket arrangement matching standard panel-mount or DIN-rail bases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the input stage handle both NPN and PNP sensor signals?\u003c\/p\u003e\n\u003cp\u003eYes, the input circuit accommodates both NPN open-collector and PNP sensor types via DIP switch or internal setup modes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature range is allowable inside the control cabinet?\u003c\/p\u003e\n\u003cp\u003eThe device is specified to operate reliably in ambient cabinet temperatures ranging from -10 to 55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat panel cutout dimensions are required for mounting?\u003c\/p\u003e\n\u003cp\u003eThe unit requires a standard square panel cutout measuring 45 x 45 mm for flush front-panel installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306659889325,"sku":"H7CX-A11S-N","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/H7CX-A11S-N.jpg?v=1789998590","url":"https:\/\/www.maxwellplc.com\/ru\/products\/h7cx-a11s-n-omron-multifunction-counter-tachometer-h7cx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}