{"product_id":"general-electric-ic693pwr331-power-supply-module-series-90-30","title":"General Electric IC693PWR331 Power Supply Module Series 90-30","description":"\u003cp dir=\"ltr\" data-path-to-node=\"6\"\u003e\u003cspan\u003eConfigured for high-capacity power distribution in General Electric Series 90-30 programmable logic controller platforms,\u003c\/span\u003e\u003cspan\u003e the \u003c\/span\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"126\"\u003eGeneral Electric IC693PWR331\u003c\/b\u003e\u003cspan\u003e (\u003c\/span\u003e\u003cb data-path-to-node=\"6\" data-index-in-node=\"156\"\u003eIC693PWR331\u003c\/b\u003e\u003cspan\u003e Power Supply Unit) provides direct physical and electrical execution of DC input conversion into regulated backplane voltage rails.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\" data-path-to-node=\"7\"\u003eHardware Configuration \u0026amp; Power Architecture\u003c\/h3\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"8\"\u003e\u003cspan\u003eThe IC693PWR331 mounts into the dedicated leftmost slot of any Series 90-30 baseplate.\u003c\/span\u003e\u003cspan\u003e It accepts an input voltage range from 18 VDC to 56 VDC,\u003c\/span\u003e\u003cspan\u003e supporting 24 VDC and 48 VDC nominal DC systems.\u003c\/span\u003e\u003cspan\u003e The unit supplies three independent voltage outputs,\u003c\/span\u003e\u003cspan\u003e including a +5 VDC logic rail (up to 30 Watts),\u003c\/span\u003e\u003cspan\u003e a +24 VDC relay rail (up to 15 Watts),\u003c\/span\u003e\u003cspan\u003e and a +24 VDC isolated rail (20 Watts) for sensitive field sensors.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\" data-path-to-node=\"9\"\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable data-path-to-node=\"10\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,0,0\"\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,1,1,0\"\u003eIC693PWR331\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,0,0\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,2,1,0\"\u003eGeneral Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,0,0\"\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,3,1,0\"\u003ePower Supply Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,0,0\"\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,4,1,0\"\u003eSeries 90-30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,0,0\"\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,5,1,0\"\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,0,0\"\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,6,1,0\"\u003e0.36 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,0,0\"\u003ePhysical Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,7,1,0\"\u003e3.5 cm L x 13.0 cm W x 13.5 cm H\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,0,0\"\u003eInput Voltage Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,8,1,0\"\u003e18 VDC to 56 VDC (24 VDC and 48 VDC nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,0,0\"\u003eLogic Power Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,9,1,0\"\u003e+5 VDC at up to 30 Watts capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,0,0\"\u003eRelay Power Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,10,1,0\"\u003e+24 VDC at up to 15 Watts capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,0,0\"\u003eIsolated Power Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,11,1,0\"\u003e+24 VDC at up to 20 Watts capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,0,0\"\u003eCommunication Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,12,1,0\"\u003eRS-485 port for programmers and software integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,13,0,0\"\u003eMemory Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,13,1,0\"\u003eIntegrated battery connection for volatile RAM preservation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,14,0,0\"\u003eMounting Position\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan data-path-to-node=\"10,14,1,0\"\u003eDedicated leftmost slot in Series 90-30 baseplate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 dir=\"ltr\" data-path-to-node=\"11\"\u003eBus Isolation and Signal Integrity\u003c\/h3\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"12\"\u003e\u003cspan\u003eOperating across Series 90-30 backplane structures,\u003c\/span\u003e\u003cspan\u003e the power supply isolates field-side circuits from internal logic processors.\u003c\/span\u003e\u003cspan\u003e The dedicated isolated +24 VDC output prevents electrical noise generated by field actuators and sensors from coupling into the backplane,\u003c\/span\u003e\u003cspan\u003e ensuring stable communication over the built-in RS-485 port and supporting reliable program execution during industrial power fluctuations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3 dir=\"ltr\" data-path-to-node=\"13\"\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul dir=\"ltr\" data-path-to-node=\"14\"\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"14,0,0\"\u003e\u003cspan\u003e1 x General Electric IC693PWR331 Power Supply Module\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"14,1,0\"\u003e\u003cspan\u003e1 x Internal Memory Backup Battery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\" data-path-to-node=\"15\"\u003eField Installation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003cul dir=\"ltr\" data-path-to-node=\"16\"\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"16,0,0\"\u003e\u003cb data-path-to-node=\"16,0,0\" data-index-in-node=\"0\"\u003eBaseplate Slot Assignment:\u003c\/b\u003e\u003cspan\u003e Mount the IC693PWR331 exclusively in the leftmost slot of the Series 90-30 baseplate.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"16,1,0\"\u003e\u003cb data-path-to-node=\"16,1,0\" data-index-in-node=\"0\"\u003ePower Isolation:\u003c\/b\u003e\u003cspan\u003e De-energize all incoming DC power sources before connecting or disconnecting wires from the front terminal block.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"16,2,0\"\u003e\u003cb data-path-to-node=\"16,2,0\" data-index-in-node=\"0\"\u003eBattery Terminal Handling:\u003c\/b\u003e\u003cspan\u003e Connect the backup battery securely to maintain program memory during primary power loss.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"16,3,0\"\u003e\u003cb data-path-to-node=\"16,3,0\" data-index-in-node=\"0\"\u003eHinged Door Maintenance:\u003c\/b\u003e\u003cspan\u003e Keep the protective swing door closed during normal operation to shield input terminals and diagnostic LEDs from physical contaminants.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 dir=\"ltr\" data-path-to-node=\"17\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul dir=\"ltr\" data-path-to-node=\"18\"\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,0,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What input voltage ranges does the IC693PWR331 support?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,0,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e The module supports 24 VDC and 48 VDC nominal input sources within an acceptable operating range of 18 VDC to 56 VDC.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,1,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e Where must this power supply be installed in the PLC rack?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,1,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e It is designed to occupy exclusively the dedicated leftmost slot of any Series 90-30 baseplate.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,2,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What independent voltage rails are provided by the unit?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,2,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e It provides three outputs:\u003c\/span\u003e\u003cspan\u003e +5 VDC for backplane logic,\u003c\/span\u003e\u003cspan\u003e +24 VDC for relay circuits,\u003c\/span\u003e\u003cspan\u003e and an isolated +24 VDC for sensitive sensors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,3,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What communication port is integrated into the module front panel?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,3,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e An RS-485 communication port is included for connecting Hand-Held Programmers or Proficy configuration software.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,4,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e How is volatile RAM memory protected during power outages?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,4,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e An integrated battery connection preserves user program memory and data registers when main input power is removed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,5,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What diagnostic LEDs are visible on the front panel?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,5,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e Front indicators include PWR for input power,\u003c\/span\u003e\u003cspan\u003e OK for internal health,\u003c\/span\u003e\u003cspan\u003e RUN for CPU status,\u003c\/span\u003e\u003cspan\u003e and BATT for battery life status.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,6,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e What are the physical dimensions and weight of the module?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,6,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e The module measures 3.\u003c\/span\u003e\u003cspan\u003e5 cm L x 13.\u003c\/span\u003e\u003cspan\u003e0 cm W x 13.\u003c\/span\u003e\u003cspan\u003e5 cm H and weighs 0.\u003c\/span\u003e\u003cspan\u003e36 kg.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,7,0\"\u003e\u003cspan\u003eQ:\u003c\/span\u003e\u003cspan\u003e Why is an isolated +24 VDC power output included?\u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\" data-path-to-node=\"18,7,1\"\u003e\u003cspan\u003eA:\u003c\/span\u003e\u003cspan\u003e The isolated output prevents electrical noise from field devices from propagating back into sensitive backplane logic circuits.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45519087829165,"sku":"IC693PWR331","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/general-electric-ic693pwr331-power-supply-5girlspwtxw.jpg?v=1766986661","url":"https:\/\/www.maxwellplc.com\/ru\/products\/general-electric-ic693pwr331-power-supply-module-series-90-30","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}