{"product_id":"ge-is215acleh1a-application-control-layer-module-ex2100-excitation-system-is215acleh1a","title":"GE IS215ACLEH1A Application Control Layer Module | EX2100 Excitation System IS215ACLEH1A","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eGE IS215ACLEH1A\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIS215ACLEH1A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eApplication Control Layer (ACL) Module, operates as a dedicated hardware component for high-level logic execution and data communication within EX2100 excitation control platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: IS215ACLEH1A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: EX2100 Excitation Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunction: Application Control Layer (ACL)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArchitecture: x86 microprocessor-based\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS215ACLEH1A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGeneral Electric (GE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 cm x 16 cm x 12 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard industrial range\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem backplane budget dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMemory\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOnboard SDRAM and Flash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISBus and 10\/100 Ethernet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControl Platform Performance\u003c\/h3\u003e\n\u003cp\u003eThe module executes deterministic application software for field current regulation and terminal voltage control. It maintains backplane bus communication velocity sufficient for real-time synchronization requirements across EX2100 racks. The integrated x86 processing core supports the computational load of Power System Stabilizer (PSS) algorithms and gateway functions for HMI interfacing. Firmware flash compatibility is managed via the control network to ensure consistency across excitation control nodes.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) IS215ACLEH1A Application Control Layer module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFactory packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting hardware for EX2100 chassis integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane Integration: Verify the chassis slot is free of debris. Slide the module into the designated guide rails, ensuring the ISBus and Ethernet backplane connectors engage correctly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Secure the module using integrated fasteners to ensure the chassis ground connection is established.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnectivity: Terminate ISBus and Ethernet cables according to the site wiring schedule; verify link status indicators post-installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration: Initialize the module via the system configuration interface to map the required application logic before putting the excitation system into service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the IS215ACLEH1A compatible with older EX2000 systems?\u003c\/p\u003e\n\u003cp\u003eA: No, this module is specifically engineered for the EX2100 Excitation Control architecture and is not cross-compatible with legacy platforms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this module support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: System documentation must be consulted; typically, a controlled shutdown of the associated excitation channel is required before module replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the firmware updated?\u003c\/p\u003e\n\u003cp\u003eA: Firmware updates are performed over the control network using the GE-provided system engineering software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the onboard memory?\u003c\/p\u003e\n\u003cp\u003eA: Onboard SDRAM and Flash memory provide the storage required for runtime execution of control algorithms and local system status logging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I monitor the module status remotely?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module provides diagnostic data through the integrated Ethernet gateway for HMI and remote maintenance access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary communication link?\u003c\/p\u003e\n\u003cp\u003eA: The module communicates via the proprietary ISBus for real-time control and standard 10\/100 Ethernet for data historian and HMI integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I identify if the module is in a fault state?\u003c\/p\u003e\n\u003cp\u003eA: Utilize the front-panel status LEDs and the excitation system management interface to view diagnostic codes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module require periodic calibration?\u003c\/p\u003e\n\u003cp\u003eA: No, the module is a digital processing unit and does not require analog calibration; performance is verified through logic software diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":45643022631085,"sku":"IS215ACLEH1A","price":469.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/IS215ACLEH1A-2__2.jpg?v=1769049401","url":"https:\/\/www.maxwellplc.com\/ru\/products\/ge-is215acleh1a-application-control-layer-module-ex2100-excitation-system-is215acleh1a","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}