{"product_id":"g9sx-ad322-t150-rc-omron-flexible-safety-unit-g9sx-series","title":"G9SX-AD322-T150-RC Omron Flexible Safety Unit G9SX Series","description":"\u003cp\u003eThe \u003cstrong\u003eOmron G9SX-AD322-T150-RC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eG9SX-AD322\u003c\/strong\u003e Flexible Safety Unit, operates as a dedicated hardware component for safety-related input evaluation and output control within G9SX Series safety architecture networks.\u003c\/p\u003e\n\u003ch3\u003eModel Identification Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eG9SX\u003c\/strong\u003e: Base series designation for Omron modular safety relay units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAD\u003c\/strong\u003e: Advanced Unit type supporting logical AND connections and expansion capabilities.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\u003c\/strong\u003e: Instantaneous safety outputs (3 P-channel MOS FET semiconductor outputs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: OFF-delayed safety outputs (2 P-channel MOS FET semiconductor outputs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: Auxiliary outputs (2 PNP transistor non-safety outputs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eT150\u003c\/strong\u003e: Maximum OFF-delay timing setting up to 150 s.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRC\u003c\/strong\u003e: Spring-cage terminal block design with screwless cage-clamp connection interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eG9SX-AD322-T150-RC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e125 mm x 115 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-15% to +10% of rated supply voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Input Voltage\u003c\/td\u003e\n\u003ctd\u003e20.4 VDC to 26.4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Input Impedance\u003c\/td\u003e\n\u003ctd\u003eapprox 2.8 kohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstantaneous Safety Output\u003c\/td\u003e\n\u003ctd\u003eP-channel MOS FET transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-delayed Safety Output\u003c\/td\u003e\n\u003ctd\u003eP-channel MOS FET transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current (\u0026lt;=2 Safety Outputs)\u003c\/td\u003e\n\u003ctd\u003e1.0 A DC max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Current (\u0026gt;=3 Safety Outputs)\u003c\/td\u003e\n\u003ctd\u003e0.8 A DC max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Output Type\u003c\/td\u003e\n\u003ctd\u003ePNP transistor (100 mA DC max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e10 to 55 to 10 Hz, 0.375-mm single amplitude\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Safety Bus \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe advanced architecture of the unit utilizes internal dual microcontrollers to continuously execute cross-monitored diagnostics across safety inputs and output control circuits. Integrated preset logic algorithms manage internal state transitions, coordinating synchronous communication via logical AND connections across connected Expansion Units. Internal processing logic maintains deterministic execution response cycles below 15 ms, isolating safety functions from external network latency. Flash memory components enforce strict firmware consistency checks during power-up boot routines, blocking hardware execution if internal self-test routines fail or voltage fluctuations breach operating thresholds.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron G9SX-AD322-T150-RC Flexible Safety Unit\u003c\/li\u003e\n\u003cli\u003e1 x Pre-installed Spring-cage Removable Terminal Block Set\u003c\/li\u003e\n\u003cli\u003e1 x Safety Instruction and Wiring Datasheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Wiring \u0026amp; Installation Directives\u003c\/h3\u003e\n\u003ch4\u003eMounting and Enclosure Setup\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the housing on standard 35-mm DIN rail inside a protective panel enclosure rated at minimum IP54 to prevent dust and moisture ingress.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 50 mm clearance above and below the module housing for natural convection airflow and cable management.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWiring and Signal Connections\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse stranded copper wiring rated for 60 deg C or 75 deg C; strip insulation back 8 mm to 9 mm before inserting directly into spring-cage terminals.\u003c\/li\u003e\n\u003cli\u003eInsert a flat-blade screwdriver (0.6 mm x 3.5 mm blade) into the rectangular unlock slot to release terminal clamp tension during wire extraction.\u003c\/li\u003e\n\u003cli\u003eRoute safety input cabling separately from high-voltage AC lines and VFD power cables to suppress inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003eConnect a 24 VDC class 2 power supply source with functional grounding to ensure transient surge suppression and isolation compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow are the OFF-delay times set on this unit?\u003c\/p\u003e\n\u003cp\u003eThe OFF-delay timer is configured using the rotary switches located behind the front protective cover, allowing preset incremental adjustments up to 150 s.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat load currents are supported by the safety outputs?\u003c\/p\u003e\n\u003cp\u003eWhen using two or fewer safety outputs, each output handles up to 1.0 A DC. When three or more outputs operate simultaneously, the limit is 0.8 A DC per channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response time when a safety input is opened?\u003c\/p\u003e\n\u003cp\u003eThe instantaneous safety outputs turn OFF within 15 ms maximum after a valid safety input signal interruption is recognized by internal logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do the spring-cage terminals handle mechanical vibration?\u003c\/p\u003e\n\u003cp\u003eSpring-cage terminals exert continuous mechanical clamping force on conductors, resisting vibration shifts from 10 to 55 Hz without requiring periodic screw retightening.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the auxiliary output provide safety-rated shut-off capabilities?\u003c\/p\u003e\n\u003cp\u003eNo, auxiliary outputs are non-safety PNP transistor channels intended exclusively for status monitoring, diagnostic feedback, and PLC signaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this unit expand its number of safety outputs?\u003c\/p\u003e\n\u003cp\u003eYes, logical AND connections on the side connector allow direct linking to G9SX Expansion Units without requiring external hardwiring between safety logic terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage limits must be maintained during operation?\u003c\/p\u003e\n\u003cp\u003eThe unit requires a 24 VDC supply with an allowable operating range between 20.4 VDC and 26.4 VDC (-15% to +10% of rated voltage).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat indicates an internal component or cross-short fault?\u003c\/p\u003e\n\u003cp\u003eThe front-panel ERR LED lights or blinks in specific flashing sequences to indicate wiring shorts, power supply anomalies, or internal microprocessor fault conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306661822637,"sku":"G9SX-AD322-T150-RC","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/G9SX-AD322.jpg?v=1789968347","url":"https:\/\/www.maxwellplc.com\/ru\/products\/g9sx-ad322-t150-rc-omron-flexible-safety-unit-g9sx-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}