{"product_id":"foxboro-fcm100et-p0926gs-fieldbus-communications-module","title":"Foxboro FCM100ET P0926GS Fieldbus Communications Module","description":"\u003cp\u003eThe Foxboro FCM100ET, part number P0926GS, is a Fieldbus Communications Module for the Foxboro I\/A Series control system. It provides a communication interface between the 100 Mbps Ethernet control network and the 2 Mbps HDLC Module Fieldbus. The module connects DIN rail-mounted Fieldbus Modules (FBMs) with the Z-Module Control Processor 270 (ZCP270). It also supports redundant operation through Master and Tracker modules, helping maintain fieldbus communications when a module fault occurs.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe FCM100ET is designed for industrial distributed control system communication infrastructure. It transfers data between Ethernet-based control networks and the HDLC fieldbus used by connected FBMs.\u003c\/p\u003e\n\u003cp\u003eIn a redundant installation, two FCM100ET modules operate together. One module acts as the active Master, while the other operates as the Tracker and monitors system activity.\u003c\/p\u003e\n\u003cp\u003eIf the active module experiences a detected failure, the system can automatically reverse the Master and Tracker roles. This architecture supports communication continuity in demanding process automation applications.\u003c\/p\u003e\n\u003cp\u003eThe FCM100ET connects to the control network through fiber-optic Ethernet connections. Its fieldbus interface uses a 2 Mbps HDLC communication bus.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFoxboro I\/A Series Fieldbus Communications Module\u003c\/li\u003e\n\u003cli\u003eManufacturer part number P0926GS\u003c\/li\u003e\n\u003cli\u003e100 Mbps Ethernet communication\u003c\/li\u003e\n\u003cli\u003e2 Mbps HDLC Module Fieldbus communication\u003c\/li\u003e\n\u003cli\u003eConnects FBMs with the ZCP270 control processor\u003c\/li\u003e\n\u003cli\u003eSupports redundant Master\/Tracker operation\u003c\/li\u003e\n\u003cli\u003eAutomatic Master\/Tracker role reversal following detected failures\u003c\/li\u003e\n\u003cli\u003eFiber-optic Ethernet network connection\u003c\/li\u003e\n\u003cli\u003eSupports up to 32 FBMs per FCM100ET\u003c\/li\u003e\n\u003cli\u003eFront-panel LEDs indicate communication activity and module status\u003c\/li\u003e\n\u003cli\u003eRemovable from the baseplate without removing power\u003c\/li\u003e\n\u003cli\u003eDesigned for DIN rail-mounted Modular Baseplates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFCM100ET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eP0926GS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFieldbus Communications Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Family\u003c\/td\u003e\n\u003ctd\u003eFoxboro I\/A Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Function\u003c\/td\u003e\n\u003ctd\u003eEthernet-to-Fieldbus Communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Fieldbus Protocol\u003c\/td\u003e\n\u003ctd\u003eHDLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Fieldbus Transmission Rate\u003c\/td\u003e\n\u003ctd\u003e2 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Processor Interface\u003c\/td\u003e\n\u003ctd\u003eZCP270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus Module Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 32 FBMs per FCM100ET\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eMaster \/ Tracker configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connection\u003c\/td\u003e\n\u003ctd\u003eFiber Optic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Type\u003c\/td\u003e\n\u003ctd\u003eMultimode Fiber, 62.5\/125 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Connector\u003c\/td\u003e\n\u003ctd\u003eLC ceramic connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFiber Transmission Distance\u003c\/td\u003e\n\u003ctd\u003eUp to 2 km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+5%, -10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e7 W at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5–95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContamination Rating\u003c\/td\u003e\n\u003ctd\u003eClass G3, ISA S71.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eModular Baseplate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Position\u003c\/td\u003e\n\u003ctd\u003eHorizontal or vertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Height\u003c\/td\u003e\n\u003ctd\u003e102 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight Including Mounting Lugs\u003c\/td\u003e\n\u003ctd\u003e114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Width\u003c\/td\u003e\n\u003ctd\u003e45 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Depth\u003c\/td\u003e\n\u003ctd\u003e104 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Weight\u003c\/td\u003e\n\u003ctd\u003eApproximately 284 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe FCM100ET connects the Ethernet control network to the I\/A Series Module Fieldbus.\u003c\/p\u003e\n\u003cp\u003eIts two communication layers perform different functions:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Network\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module communicates with the ZCP270 through a 100 Mbps Ethernet network. Fiber-optic connections provide extended transmission distances and help reduce electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModule Fieldbus\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module interfaces with the 2 Mbps HDLC bus used by the FBMs. This communication path allows fieldbus modules to exchange data with the control processor.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Communication\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA redundant arrangement uses two FCM100ET modules and a pair of optical splitter\/combiners. The active Master handles communications, while the Tracker monitors the system.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRedundant Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe FCM100ET supports redundant fieldbus communication through a Master\/Tracker configuration.\u003c\/p\u003e\n\u003cp\u003eThe Master module performs active communication functions. Meanwhile, the Tracker monitors the active module and remains available for role reversal.\u003c\/p\u003e\n\u003cp\u003eWhen the system detects a qualifying failure, the modules can automatically switch roles. System Management software also allows users to change the roles manually.\u003c\/p\u003e\n\u003cp\u003eFor each FBM grouping, a pair of FCM100ET modules is required in the documented redundant configuration. Each grouping can contain up to 32 FBMs, subject to ZCP270 sizing constraints.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe FCM100ET mounts on a compatible Foxboro Modular Baseplate. The baseplate supports DIN rail installation and can be configured horizontally or vertically.\u003c\/p\u003e\n\u003cp\u003eFor redundant installations, the two modules must occupy adjacent odd and even positions. Supported slot combinations include positions 1 and 2, 3 and 4, 5 and 6, or 7 and 8.\u003c\/p\u003e\n\u003cp\u003eBefore installation, verify the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe system uses a compatible Foxboro I\/A Series architecture.\u003c\/li\u003e\n\u003cli\u003eThe control processor supports the FCM100ET configuration.\u003c\/li\u003e\n\u003cli\u003eThe installed Modular Baseplate is suitable for this module.\u003c\/li\u003e\n\u003cli\u003eThe Ethernet fiber connections match the required network arrangement.\u003c\/li\u003e\n\u003cli\u003eThe 24 VDC power supply meets the specified input range.\u003c\/li\u003e\n\u003cli\u003eRedundant configurations include the required companion module and splitter\/combiner assemblies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe FCM100ET can be removed or replaced without removing power from the baseplate. However, replacement should follow the site's maintenance and system safety procedures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the Foxboro FCM100ET P0926GS?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is a Fieldbus Communications Module used in the Foxboro I\/A Series system to connect Ethernet control networks with the 2 Mbps HDLC Module Fieldbus.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What communication speeds does the FCM100ET support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports 100 Mbps Ethernet communication and 2 Mbps HDLC Module Fieldbus communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Which controller is compatible with the FCM100ET?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe product specification identifies the Z-Module Control Processor 270 (ZCP270) as its control processor interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Does the FCM100ET support redundant operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Two modules can operate in a Master\/Tracker configuration, with automatic role reversal when qualifying failures are detected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5. How many FBMs can one FCM100ET support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe documented maximum is 32 FBMs per FCM100ET, subject to the control processor's sizing constraints.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e6. What power supply does the FCM100ET require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt requires 24 VDC, with an input tolerance of +5% and -10%. Maximum power consumption is 7 W.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e7. What are the dimensions and weight of the FCM100ET?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module measures approximately 102 × 45 × 104 mm. Its height is 114 mm when including mounting lugs, and its approximate weight is 284 g.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e8. Can the FCM100ET be replaced without removing power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Foxboro product documentation states that the module can be removed or replaced from its baseplate without removing power. Follow the applicable maintenance procedures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRelated Foxboro Products\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe following components are associated with the FCM100ET installation architecture:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFoxboro ZCP270 – Z-Module Control Processor\u003c\/li\u003e\n\u003cli\u003eFoxboro Modular Baseplate – DIN Rail Mounted Module Baseplate\u003c\/li\u003e\n\u003cli\u003eFoxboro FBM Series – Fieldbus Modules\u003c\/li\u003e\n\u003cli\u003eFoxboro FCM100E – Fieldbus Communications Module\u003c\/li\u003e\n\u003cli\u003eFoxboro FCM100ET Splitter\/Combiner – Redundant Fiber-Optic Network Component\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":68382787764397,"sku":"FCM100ET P0926GS","price":599.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/fcm100etp0926gs_2.jpg?v=1795162751","url":"https:\/\/www.maxwellplc.com\/ru\/products\/foxboro-fcm100et-p0926gs-fieldbus-communications-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}