{"product_id":"f3sj-e0625p25-omron-f3sj-series-safety-light-curtain","title":"F3SJ-E0625P25 Omron F3SJ Series Safety Light Curtain","description":"\u003cp\u003eThe \u003cstrong\u003eOmron F3SJ-E0625P25\u003c\/strong\u003e serves as the primary \u003cstrong\u003eF3SJ-E\u003c\/strong\u003e Safety Light Curtain utilized to execute machine guarding optical sensing and interruption signal switching across safety controller platforms.\u003c\/p\u003e\n\u003ch3\u003ePart Number Structure \u0026amp; Model Decoding\u003c\/h3\u003e\n\u003cp\u003eThe internal cataloging format defines functional classification, protective height, output circuit configuration, and resolution spacing across the series matrix:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3SJ-E\u003c\/strong\u003e: Easy-type base series providing core optical presence detection without complex software configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0625\u003c\/strong\u003e: Specifies a 625 mm vertical protective height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP\u003c\/strong\u003e: PNP open-collector output circuit configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25\u003c\/strong\u003e: Indicates 20 mm optical beam gap yielding a 25-mm diameter detection capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data Sheet\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3SJ-E0625P25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e720 mm x 120 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eEmitter: 57 mA max.; Receiver: 47 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003eSELV\/PELV 24 VDC +\/-20% (ripple p-p 10% max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003ePNP output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Count\u003c\/td\u003e\n\u003ctd\u003e30 beams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Height\u003c\/td\u003e\n\u003ctd\u003e625 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eType 4 safety light curtain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHand and Arm Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Capability\u003c\/td\u003e\n\u003ctd\u003e25-mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Gap\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003e0.2 to 7 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eInfrared LED (870 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP \u0026amp; Deterministic Bus Operations\u003c\/h3\u003e\n\u003cp\u003eThe safety sensor array interfaces directly with safety input channels to maintain deterministic response timing across Profinet and EtherNet\/IP networks. Optimized firmware flash compatibility ensures synchronized status reporting to PLC safety CPUs, maintaining high I\/O density scaling and predictable safety-off trip times without introducing communication delay onto the fieldbus network.\u003c\/p\u003e\n\u003ch3\u003eDeliverables \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron F3SJ-E0625P25 Light Curtain Emitter\u003c\/li\u003e\n\u003cli\u003e1 x Omron F3SJ-E0625P25 Light Curtain Receiver\u003c\/li\u003e\n\u003cli\u003e1 x Standard Top\/Bottom Mounting Bracket Set\u003c\/li\u003e\n\u003cli\u003e1 x Hardware Wiring and Setup Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003ch4\u003ePhysical Alignment \u0026amp; Assembly\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall emitter and receiver on rigid, vibration-free structural profiles at matched heights.\u003c\/li\u003e\n\u003cli\u003eEnsure full parallelism between optical faces using line-of-sight laser tools before tightening brackets.\u003c\/li\u003e\n\u003cli\u003eMaintain the optical distance strictly within the specified 0.2 to 7 m operating range.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower Supply \u0026amp; Signal Shielding\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the system exclusively to a regulated SELV\/PELV 24 VDC source with less than 10% ripple.\u003c\/li\u003e\n\u003cli\u003eIsolate output and power cables from AC drive outputs, motor cables, and high-frequency noise sources.\u003c\/li\u003e\n\u003cli\u003eGround the aluminum housing enclosure and cable shielding to a low-impedance earth terminal to suppress EMI.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Troubleshooting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power supply parameters are required for reliable sensor operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The device requires a SELV\/PELV 24 VDC power supply with +\/-20% voltage tolerance and maximum peak-to-peak ripple under 10% to prevent internal reset conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is live hot-swapping permitted on this light curtain model during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, hot-swapping is prohibited. Always de-energize the 24 VDC power supply prior to disconnecting or reconnecting sensor cables to prevent short-circuit output damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the exact detection capability provided by this 30-beam unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 20 mm beam gap delivers a 25-mm diameter detection capability, which provides certified hand and arm protection across the full 625 mm protective height.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do the PNP safety outputs function under uninterrupted conditions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: In a clear optical state, dual PNP transistors source 24 VDC actively to the connected safety relay or controller input terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the no-load current consumption for this specific beam configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: At 30 beams, the emitter consumes a maximum of 57 mA, while the receiver consumes up to 47 mA from the 24 VDC power line under no-load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What ingress protection rating applies to the sensor enclosure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The sensor enclosure meets IP65 standards, offering protection against total dust ingress and low-pressure water jets from any direction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the system handle high-frequency electrical noise from surrounding machinery?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Internal optical filtering combined with proper single-point shield grounding prevents electromagnetic interference from causing false output trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What optical emitter technology is utilized in the transmitter head?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The emitter head houses an array of infrared LEDs operating at an emitted peak wavelength of 870 nm to send synchronized pulses to the receiver.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306666705069,"sku":"F3SJ-E0625P25","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/F3SJ-E0385P25_2.jpg?v=1789709348","url":"https:\/\/www.maxwellplc.com\/ru\/products\/f3sj-e0625p25-omron-f3sj-series-safety-light-curtain","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}