{"product_id":"f3sj-e0465n25-omron-safety-light-curtain-f3sj-series","title":"F3SJ-E0465N25 Omron Safety Light Curtain F3SJ Series","description":"\u003cp\u003eConfigured for optical interruption detection and safe circuit trip generation in machine guard control loops, the \u003cstrong\u003eOmron F3SJ-E0465N25\u003c\/strong\u003e (\u003cstrong\u003eF3SJ-E\u003c\/strong\u003e Safety Light Curtain) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003ePart Number Code Structure\u003c\/h3\u003e\n\u003cp\u003eThe factory model code specifies operational design, effective protective height, switching output logic, and beam resolution limits:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3SJ-E\u003c\/strong\u003e: Easy-type series platform dedicated to basic presence sensing without requiring software initialization.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e0465\u003c\/strong\u003e: Defines a vertical protective height of 465 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Represents NPN open-collector switching logic outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25\u003c\/strong\u003e: Indicates a 20 mm optical beam gap establishing a 25-mm diameter object detection capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Operational Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3SJ-E0465N25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e560 mm x 120 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eEmitter: 41 mA max.; Receiver: 40 mA max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003eSELV\/PELV 24 VDC +\/-20% (ripple p-p 10% max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eType 4 safety light curtain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eNPN output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Count\u003c\/td\u003e\n\u003ctd\u003e22 beams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective Height\u003c\/td\u003e\n\u003ctd\u003e465 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHand and Arm Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Capability\u003c\/td\u003e\n\u003ctd\u003e25-mm diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeam Gap\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Range\u003c\/td\u003e\n\u003ctd\u003e0.2 to 7 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eInfrared LED (870 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eNetwork Connectivity \u0026amp; Deterministic Bus Performance\u003c\/h3\u003e\n\u003cp\u003eThe device interfaces with programmable safety controllers using deterministic communication networks such as EtherNet\/IP and Profinet. Maintaining tight backplane execution speeds and high I\/O density scaling, the sensor hardware provides consistent logic state updates. Complete firmware flash compatibility across safety platforms ensures repeatable safety-off trip times during beam blockage events.\u003c\/p\u003e\n\u003ch3\u003eBill of Materials \u0026amp; Ordering Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron F3SJ-E0465N25 Emitter Housing\u003c\/li\u003e\n\u003cli\u003e1 x Omron F3SJ-E0465N25 Receiver Housing\u003c\/li\u003e\n\u003cli\u003e1 x Mounting Bracket Hardware Set\u003c\/li\u003e\n\u003cli\u003e1 x Hardware Alignment and Setup Manual\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Alignment \u0026amp; Mounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMount the optical emitter and receiver perfectly parallel on rigid frames to prevent vibration misalignment.\u003c\/li\u003e\n\u003cli\u003eVerify that both optical heads maintain equal height levels using line-of-sight laser tools.\u003c\/li\u003e\n\u003cli\u003eEnsure total separation distance remains within the designated 0.2 to 7 m operating window.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCable Routing \u0026amp; Shielding Practices\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProvide 24 VDC strictly from a SELV\/PELV rated power supply with peak-to-peak ripple restricted to 10% max.\u003c\/li\u003e\n\u003cli\u003eRun sensor wiring through dedicated conduits away from AC motor conductors and VFD switching lines.\u003c\/li\u003e\n\u003cli\u003eConnect the aluminum housing and cable shielding directly to a single protective earth point to eliminate ground loops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Diagnostics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What voltage stability range is necessary for correct module execution?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module requires a SELV\/PELV 24 VDC supply with a +\/-20% input tolerance, keeping peak-to-peak ripple below 10% max to preserve logic stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is live cable insertion or removal permitted while the safety circuit is powered?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, live cable swaps are prohibited. Always isolate power to the safety system prior to disconnecting or reconnecting sensor wiring to prevent output transistor damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What specific physical resolution does this 22-beam curtain provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Featuring a 20 mm optical beam gap, the unit achieves a 25-mm diameter detection capability, engineered specifically for hand and arm intrusion protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do the NPN safety outputs function under unobstructed path conditions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: When the sensing zone is clear, the NPN output transistors sink load current actively down to the 0 VDC reference rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum current draw of the emitter and receiver during active operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: For a 22-beam array under no-load conditions, the emitter draws up to 41 mA max and the receiver draws up to 40 mA max from the 24 VDC supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What environmental protection standard applies to the sensor housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The extruded aluminum housing complies with IP65 ingress standards, protecting against dust penetration and direct low-pressure water sprays.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What light source wavelength is generated by the transmitter diode array?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The transmitter optical array utilizes infrared LEDs emitting at a peak wavelength of 870 nm to maintain optical link alignment with the receiver.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How can noise-induced signal drops be prevented near high-voltage equipment?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Ensure signal cable shielding terminates at a clean protective earth point and maintain strict physical clearance from high-voltage motor wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306664738989,"sku":"F3SJ-E0465N25","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/F3SJ-E0465N25-1.jpg?v=1789709435","url":"https:\/\/www.maxwellplc.com\/ru\/products\/f3sj-e0465n25-omron-safety-light-curtain-f3sj-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}