{"product_id":"ei813f-3bdh000022r1-abb-ethernet-fieldbus-module-ac800f","title":"EI813F 3BDH000022R1 ABB Ethernet Fieldbus Module AC800F","description":"\u003cp\u003eThe \u003cstrong\u003eABB EI813F 3BDH000022R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eEI813F\u003c\/strong\u003e Ethernet Fieldbus Module, operates as a dedicated hardware component for 10BaseT Ethernet communication tasks within AC800F networks.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix and Designation Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase model designation: EI813F representing the Ethernet fieldbus module variant.\u003c\/li\u003e\n\u003cli\u003ePart number identifier: 3BDH000022R1 specifying the exact manufacturing production build.\u003c\/li\u003e\n\u003cli\u003eNetwork interface: Supports 10BaseT Ethernet physical layer data transmission at 10 Mbps.\u003c\/li\u003e\n\u003cli\u003eSystem integration: Designed for deployment alongside PM 802F or PM 803F controller units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEI813F 3BDH000022R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.7 x 12.8 x 15.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2.4 W (100 mA at 24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 100 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Rate\u003c\/td\u003e\n\u003ctd\u003e10 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eControl Bus Communication and System Processing Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManages backplane bus communication velocity and protocol translation across industrial control networks.\u003c\/li\u003e\n\u003cli\u003eEnforces firmware flash compatibility and real-time data packet processing routines during network communication.\u003c\/li\u003e\n\u003cli\u003eMaintains strict adherence to Profinet \/ EtherNet\/IP deterministic networks where applicable system configuration rules apply.\u003c\/li\u003e\n\u003cli\u003eExecutes I\/O density scaling support to handle connected network nodes efficiently without data bottlenecking.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x EI813F Ethernet Fieldbus Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Technical documentation sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation and Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely onto the designated backplane slot within the AC800F rack chassis.\u003c\/li\u003e\n\u003cli\u003eEnsure proper ground bonding of the enclosure frame prior to applying the 24 V DC operating power supply.\u003c\/li\u003e\n\u003cli\u003eConnect shielded 10BaseT Ethernet cabling, maintaining strict separation from high-voltage power distribution lines.\u003c\/li\u003e\n\u003cli\u003eVerify LED status indicators post-installation to confirm active link status and power rail stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the primary function of the EI813F module?\u003c\/p\u003e\n\u003cp\u003eA: It serves as an Ethernet fieldbus module providing 10BaseT network connectivity for AC800F controllers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Which controller models are compatible with this Ethernet module?\u003c\/p\u003e\n\u003cp\u003eA: It is designed to be used together with PM 802F or PM 803F processor units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum data transmission rate supported?\u003c\/p\u003e\n\u003cp\u003eA: The module supports a data transfer rate of 10 Mbps over 10BaseT physical media.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What power supply voltage is required for operation?\u003c\/p\u003e\n\u003cp\u003eA: The unit operates on a nominal 24 V DC power supply with a current draw of 100 mA or less.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is hot-swapping supported for this fieldbus module?\u003c\/p\u003e\n\u003cp\u003eA: Power must be removed from the rack before inserting or extracting the hardware to prevent electrical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the isolation voltage rating for the module's circuitry?\u003c\/p\u003e\n\u003cp\u003eA: The unit provides an isolation rating of 1500 V DC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the operating temperature range limit?\u003c\/p\u003e\n\u003cp\u003eA: It is engineered to function within ambient temperatures from -20 deg C to +70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How are communication errors monitored during runtime?\u003c\/p\u003e\n\u003cp\u003eA: Internal diagnostic registers track packet integrity and signal status, reflecting states via front-panel LEDs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021160894637,"sku":"EI813F 3BDH000022R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/EI813F_3BDH000022R1_14.jpg?v=1784812777","url":"https:\/\/www.maxwellplc.com\/ru\/products\/ei813f-3bdh000022r1-abb-ethernet-fieldbus-module-ac800f","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}