{"product_id":"dx910s-3kde175311l9100-abb-advant-s900-i-o-digital-i-o-module","title":"DX910S 3KDE175311L9100 ABB Advant S900 I\/O Digital I\/O Module","description":"\u003cp\u003eThe \u003cb\u003eABB DX910S 3KDE175311L9100\u003c\/b\u003e serves as the primary \u003cb\u003eDX910S\u003c\/b\u003e Digital I\/O Module utilized to execute discrete field signal acquisition and switching across ABB Advant S900 I\/O platforms. Designed for direct insertion into S900 terminal units, the unit interfaces field-level binary signals with the remote I\/O fieldbus communication interface. The internal processing circuitry provides galvanic isolation between external field wiring loops and the internal system backplane, managing discrete input states and output control signals for distributed control system execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Designation \u0026amp; Part Identifier\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDX910S\u003c\/b\u003e: Designates the S900 system configurable digital input\/output module hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e3KDE175311L9100\u003c\/b\u003e: Identifies the exact ABB manufacturing part number for ordering and trace verification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAdvant S900 I\/O\u003c\/b\u003e: Represents the underlying remote I\/O platform designed for process automation panel integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Physical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDX910S 3KDE175311L9100\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 10.5 x 11 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunction Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConfigurable Digital Input \/ Digital Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eField Bus Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVia S900 Terminal Unit Backplane\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 (Module Housing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBackplane Integration \u0026amp; Deterministic Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe module transfers binary state data across the internal S900 backplane bus to the central fieldbus gateway module. High-speed backplane bus communication velocity guarantees rapid cycle updates for channel status registers and field loop diagnostics. Microprocessor logic maintains complete firmware flash compatibility with S900 head stations, allowing dynamic system optimization, scalable I\/O density scaling, and continuous signal processing over PROFIBUS DP or Profinet deterministic networks.\u003c\/p\u003e\n\u003ch3\u003ePackage Dispatch List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB DX910S 3KDE175311L9100 Digital I\/O Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Printed Field Technical Datasheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Assembly \u0026amp; Field Cabling Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eModule Installation on Terminal Units\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the DX910S module keyways with the assigned slot on the S900 terminal unit and press firmly until locked.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain adequate ventilation clearance within the panel enclosure to prevent localized ambient thermal buildup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring and Noise Suppression Rules\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRoute field signal cables in separate wiring trunks isolated from high-voltage AC power distribution circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure field cable shields are grounded at the enclosure entrance terminal bar to prevent electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat function does the ABB DX910S 3KDE175311L9100 module perform in an S900 system?\u003c\/p\u003e\n\u003cp\u003eThe module acquires discrete input signals or drives digital output devices for processing by the central fieldbus node.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the DX910S module be hot-swapped while the S900 system is operational?\u003c\/p\u003e\n\u003cp\u003eYes, the S900 backplane architecture allows module removal and replacement under power without disturbing adjacent channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is fieldbus communication managed for the DX910S module?\u003c\/p\u003e\n\u003cp\u003eData passes directly through the internal S900 backplane to the fieldbus interface unit connected to the main control network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat parameter checks should be verified prior to inserting a replacement module?\u003c\/p\u003e\n\u003cp\u003eEnsure the mechanical slot keying matches the DX910S specifications and that system node configuration registers are updated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the module signal channel faults to the host DCS controller?\u003c\/p\u003e\n\u003cp\u003eDiagnostic logic detects loop errors and transmits specific fault status bits over the internal backplane to the host system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat enclosure protection level does the module housing provide?\u003c\/p\u003e\n\u003cp\u003eThe DX910S module features an IP20 rating and must be housed within a protective dust- and moisture-proof enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the firmware on the DX910S module field-upgradable?\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility allows management via standard S900 system software utilities through the fieldbus interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding precautions must be taken during field cable landing?\u003c\/p\u003e\n\u003cp\u003eConnect all cable shields to the dedicated grounding rail on the S900 terminal base to prevent ground loop currents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021150703789,"sku":"DX910S 3KDE175311L9100","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/DX910S-1-0.jpg?v=1786071650","url":"https:\/\/www.maxwellplc.com\/ru\/products\/dx910s-3kde175311l9100-abb-advant-s900-i-o-digital-i-o-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}