{"product_id":"do810-3bse008510r1-abb-digital-output-modules-s800-i-o","title":"DO810 3BSE008510R1 ABB Digital Output Modules S800 I\/O","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDO810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3BSE008510R1\u003c\/strong\u003e)\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDigital Output Module\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDO810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDigital Output Module\u003c\/strong\u003e, operates as a dedicated hardware component for signal processing or control execution within industrial automation architectures. This module is specifically engineered for the ABB S800 I\/O system, providing 16 high-speed digital output channels for controlling field devices such as solenoids, contactors, and actuators. Each channel is designed to deliver a stable 10–30 V DC output signal with integrated protective circuitry. The module architecture enables integration into distributed control systems, allowing for granular control of discrete process variables while maintaining electrical isolation between channel groups.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDO810 (3BSE008510R1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 x 11 x 0.15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (Bus Powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 (Two groups of eight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Parameters\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10–30 V DC, 0.5 A max per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBrand-Specific Technical Block\u003c\/h3\u003e\n\u003cp\u003eThe DO810 utilizes the ABB S800 I\/O backplane communication bus to facilitate deterministic data transfer between the module and the host controller. The design features high I\/O density by grouping sixteen channels into two electrically isolated eight-channel segments. Communication is managed through the ModuleBus protocol, which ensures real-time diagnostic reporting of short-circuit, overvoltage, and thermal overload status to the engineering station. Firmware compatibility is maintained through the system configuration software, ensuring that the module accurately maps output states from the controller application logic to the physical field terminals.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIncluded items: DO810 Digital Output Module, MTU (Module Termination Unit) interface connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard package: Industrial electrostatic protective packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional accessories: Spare field terminal blocks, cable trunking markers, redundant module housing kits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the DO810 module onto an appropriate S800 I\/O MTU (Module Termination Unit), ensuring the mechanical locking pins are fully seated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround the system MTU rail to the cabinet common earth to provide a low-impedance path for EMI suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtilize shielded cabling for all field output wiring if the cable runs exceed typical local branch requirements to minimize electrical noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure output wiring current does not exceed 0.5 A per channel to prevent tripping the internal thermal overload protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eObserve physical clearance requirements between the output module and high-power inverter or drive cabling within the control cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that the ModuleBus connection is intact before applying 24 V DC auxiliary power to the MTU.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the DO810 support hot-swap behavior?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping within an S800 I\/O system; the module can be replaced during operation without removing power from the backplane.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module affect backplane load?\u003c\/p\u003e\n\u003cp\u003eA: The DO810 draws a specific current from the ModuleBus; verify the total power budget of the S800 rack before adding additional modules.\u003c\/p\u003e\n\u003cp\u003eQ: Is there a redundancy switching delay?\u003c\/p\u003e\n\u003cp\u003eA: Redundancy switching for the DO810 is managed by the host system controller logic; delay is defined by the system scan cycle and failover configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Is firmware compatibility required?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module must be compatible with the system’s current I\/O configuration and controller firmware revision for proper diagnostic reporting.\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit provide signal isolation?\u003c\/p\u003e\n\u003cp\u003eA: The module features electrical isolation between the two channel groups (eight channels each) and the ModuleBus interface.\u003c\/p\u003e\n\u003cp\u003eQ: What are the field wiring constraints?\u003c\/p\u003e\n\u003cp\u003eA: Wiring must be rated for the expected output current and voltage; avoid exceeding the maximum thermal limit of the terminal blocks.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module detect open-load conditions?\u003c\/p\u003e\n\u003cp\u003eA: The diagnostic features primarily focus on short-circuit and overvoltage; open-load detection depends on the specific host system configuration.\u003c\/p\u003e\n\u003cp\u003eQ: How is the fault signaled?\u003c\/p\u003e\n\u003cp\u003eA: Faults are signaled via the ModuleBus to the controller, and the local channel LED will indicate an error state for quick troubleshooting.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231183233197,"sku":"3BSE008510R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-do810-3bse008510r1-digital-output-module-eixodz3asmx_5004102c-c5a8-4af7-98a0-72633861f6ae.jpg?v=1762942359","url":"https:\/\/www.maxwellplc.com\/ru\/products\/do810-3bse008510r1-abb-digital-output-modules-s800-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}