{"product_id":"cpm1a-10cdt-a-v1-omron-cpm1a-series-programmable-controller","title":"CPM1A-10CDT-A-V1 Omron CPM1A Series Programmable Controller","description":"\u003cp\u003eThe \u003cstrong\u003eOmron CPM1A-10CDT-A-V1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCPM1A\u003c\/strong\u003e Programmable Controller, operates as a dedicated hardware component for direct digital I\/O processing and high-speed pulse count verification within stand-alone automation panels.\u003c\/p\u003e\n\u003ch3\u003eNomenclature Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPM1A\u003c\/strong\u003e: Compact Micro PLC Base Platform\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10\u003c\/strong\u003e: Total Integrated I\/O Point Capacity (6 Digital Inputs \/ 4 Transistor Outputs)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC\u003c\/strong\u003e: CPU Unit with Integrated I\/O Terminals\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: 24 VDC Discrete Input Signal Processing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eT\u003c\/strong\u003e: NPN Transistor Sink Output Configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: 85 to 264 VAC Line Voltage Power Input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eV1\u003c\/strong\u003e: Version 1 Hardware and Processing Upgrade Baseline\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications Summary\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCPM1A-10CDT-A-V1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.1 kg (Shipping)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e90 mm x 66 mm x 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 VA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e6 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e4 points (Transistor sink type)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Capacity\u003c\/td\u003e\n\u003ctd\u003e2 kWords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory\u003c\/td\u003e\n\u003ctd\u003e1 kWords\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExecution Speed\u003c\/td\u003e\n\u003ctd\u003e0.72 us to 1.72 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-In Functions\u003c\/td\u003e\n\u003ctd\u003e1 Encoder input (5 kHz), 1 Pulse output (2 kHz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Support\u003c\/td\u003e\n\u003ctd\u003eNot supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLogic Execution Velocity \u0026amp; Firmware Flash Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe central processing architecture executes ladder instructions at scan velocities between 0.72 us and 1.72 us per basic instruction. System initialization runs an integrated firmware flash compatibility check on internal ROM address space to maintain deterministic cyclic task updates across local I\/O update buffers.\u003c\/p\u003e\n\u003ch3\u003ePackage Inventory\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CPM1A-10CDT-A-V1 PLC Base Controller\u003c\/li\u003e\n\u003cli\u003e1 x Removable Terminal Block Safety Cover\u003c\/li\u003e\n\u003cli\u003e1 x Instruction Sheet and Wiring Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMounting \u0026amp; Electrical Isolation Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the controller vertically on a 35 mm DIN rail or attach directly to a grounded panel backing plate using M4 screws.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum clearance of 50 mm above and below the housing to allow natural thermal convection.\u003c\/li\u003e\n\u003cli\u003eConnect the line power ground terminal directly to a heavy-duty copper earth bar using AWG 14 minimum copper wire.\u003c\/li\u003e\n\u003cli\u003eRoute NPN sink output wires separately from incoming AC main lines to minimize capacitive noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat exact input and output channel count is provided on the terminal blocks?\u003c\/p\u003e\n\u003cp\u003eThe terminal strip incorporates 6 discrete input points rated for 24 VDC signals and 4 NPN transistor sink output channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan additional local expansion I\/O modules be added to this model?\u003c\/p\u003e\n\u003cp\u003eNo, the CPM1A-10CDT-A-V1 is a non-expandable micro CPU unit designed exclusively for fixed 10-point I\/O applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat high-speed counting functions are integrated directly into the processing hardware?\u003c\/p\u003e\n\u003cp\u003eThe CPU features one built-in high-speed encoder input capable of tracking pulses up to 5 kHz and one dedicated 2 kHz pulse output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping or live terminal removal permitted during operation?\u003c\/p\u003e\n\u003cp\u003eHot-swapping is strictly prohibited. Power must be fully disconnected before removing wire leads or terminal covers to prevent hardware failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the system handle internal ladder program and data memory storage?\u003c\/p\u003e\n\u003cp\u003eThe CPU provides 2 kWords of user program capacity and 1 kWord of data memory, maintained by non-volatile flash memory and backup capacitor circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operational line voltage limits are supported by the AC power supply?\u003c\/p\u003e\n\u003cp\u003eThe internal power unit accepts an AC input range from 85 VAC to 264 VAC at a frequency of 50\/60 Hz with a maximum load of 20 VA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if a firmware flash mismatch occurs during programming updates?\u003c\/p\u003e\n\u003cp\u003eThe CPU halts ladder program execution, turns on the ERROR LED indicator, and sets system flags to prevent corrupt instruction execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat wire gauge is specified for the AC line power terminal connections?\u003c\/p\u003e\n\u003cp\u003eUse stranded copper wires with a cross-sectional area of 0.75 mm sq to 2.0 mm sq (AWG 18 to AWG 14) stripped to 6 mm length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306658381997,"sku":"CPM1A-10CDT-A-V1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/cpm1a-10cdt-a-v1-1.jpg?v=1790659826","url":"https:\/\/www.maxwellplc.com\/ru\/products\/cpm1a-10cdt-a-v1-omron-cpm1a-series-programmable-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}