{"product_id":"cp1e-n40s1dr-a-omron-programmable-logic-controller-cp1e-series","title":"CP1E-N40S1DR-A Omron Programmable Logic Controller CP1E Series","description":"\u003cp\u003eConfigured for high-speed digital logic processing and discrete output switching in industrial automation networks, the \u003cstrong\u003eOmron CP1E-N40S1DR-A\u003c\/strong\u003e (\u003cstrong\u003eCP1E-N40\u003c\/strong\u003e Programmable Controller) provides direct physical\/electrical execution across discrete control loops.\u003c\/p\u003e\n\u003ch3\u003eModel Decoder \u0026amp; Variant Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe part number CP1E-N40S1DR-A defines key hardware structures within the Omron CP1E compact controller architecture:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCP1E\u003c\/strong\u003e: Identifies the primary compact PLC controller series.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Designates application-type CPU unit equipped with built-in RS-232C communication port.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40\u003c\/strong\u003e: Specifies 40 total built-in I\/O points (24 inputs and 16 outputs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eS1\u003c\/strong\u003e: Denotes updated hardware renewal CPU unit with built-in clock\/calendar function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: Indicates 24 VDC inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR\u003c\/strong\u003e: Represents electromechanical relay outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Identifies 100 to 240 VAC main operating power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Technical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCP1E-N40S1DR-A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.66 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 110 mm x 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC (50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 VA max at 100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e24 points (24 VDC, 5 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd\u003e16 points (Relay, 2 A per point, 250 VAC \/ 24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Capacity\u003c\/td\u003e\n\u003ctd\u003e8K steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Memory Capacity\u003c\/td\u003e\n\u003ctd\u003e8K words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eArchitecture Architecture \u0026amp; Bus Execution\u003c\/h3\u003e\n\u003cp\u003eThe CP1E-N40S1DR-A incorporates optimized backplane bus communication velocity for rapid updates across local expansion modules. Standard firmware flash compatibility preserves non-volatile user programs and data memory configurations during line power loss. The core processing unit processes high-speed interrupt inputs and high-density I\/O scanning cycles, driving reliable real-time program execution across embedded relay channels and external expansion units.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CP1E-N40S1DR-A CPU Unit\u003c\/li\u003e\n\u003cli\u003e1 x Set of removable screw terminal blocks (pre-mounted)\u003c\/li\u003e\n\u003cli\u003e1 x Installation manual sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Mounting and Wiring Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the controller to a rigid 35 mm DIN rail or surface-mount using M4 screws inside an IP54 industrial enclosure.\u003c\/li\u003e\n\u003cli\u003eMaintain a clearance space of at least 50 mm above and below the housing to facilitate vertical thermal airflow cooling.\u003c\/li\u003e\n\u003cli\u003eRoute AC supply cables away from sensitive DC input lines to minimize capacitive noise coupling.\u003c\/li\u003e\n\u003cli\u003eGround the functional earth (FE) terminal using standard copper conductor rated for low-impedance grounding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the main operational power input range supported by this controller?\u003c\/p\u003e\n\u003cp\u003eA: The CPU operates directly from an AC utility source ranging from 100 to 240 VAC at 50\/60 Hz without requiring external power adapters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What type of output circuitry is embedded on the output terminals?\u003c\/p\u003e\n\u003cp\u003eA: The unit utilizes mechanical relay contacts rated for switching up to 2 A at 250 VAC or 24 VDC per output channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this CPU unit include an integrated serial communication port?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit includes a built-in RS-232C serial port along with a standard USB 2.0 peripheral port for programming and HMI interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the total digital I\/O point count available on the base unit?\u003c\/p\u003e\n\u003cp\u003eA: The base unit provides 40 total integrated discrete I\/O points, divided into 24 inputs and 16 relay outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is firmware program memory preserved during an unpowered state?\u003c\/p\u003e\n\u003cp\u003eA: Yes, user application programs are stored in non-volatile flash memory, securing logic up to 8K steps without battery power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this model be expanded with additional expansion I\/O units?\u003c\/p\u003e\n\u003cp\u003eA: Yes, up to three CP1W series expansion modules can be connected via the right-side expansion bus connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What wire gauge should be used for terminal block connections?\u003c\/p\u003e\n\u003cp\u003eA: Use stranded or solid copper wires with cross-sectional areas between 0.2 mm2 and 1.5 mm2 for terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What ambient operating conditions are permitted for continuous run mode?\u003c\/p\u003e\n\u003cp\u003eA: The hardware operates within ambient temperatures from 0 to 55 deg C and relative non-condensing humidity from 10% to 90%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306628890797,"sku":"CP1E-N40S1DR-A","price":153.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CP1E-N40S1DR-A_1.jpg?v=1788844072","url":"https:\/\/www.maxwellplc.com\/ru\/products\/cp1e-n40s1dr-a-omron-programmable-logic-controller-cp1e-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}