{"product_id":"cj1w-nc113-omron-position-control-unit-cj-series","title":"CJ1W-NC113 Omron Position Control Unit CJ-series","description":"\u003cp\u003eConfigured for open-loop single-axis pulse train motion execution in CJ-series PLC systems, the \u003cstrong\u003eOmron CJ1W-NC113\u003c\/strong\u003e (\u003cstrong\u003eCJ1W-NC113\u003c\/strong\u003e Position Control Unit) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration and Variant Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eOmron CJ1W-NC113\u003c\/strong\u003e occupies a single Special I\/O Unit slot on the CJ-series CPU rack or expansion rack. Its part numbering hierarchy reflects system allocation parameters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCJ1W\u003c\/strong\u003e: Dedicated I\/O module platform designed for CJ1G, CJ1M, CJ2M, and CJ2H PLC backplanes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNC\u003c\/strong\u003e: Motion control designation indicating direct pulse train generation for stepper or servo driver command inputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e113\u003c\/strong\u003e: Structural designator representing a single-axis hardware channel (\"1\") utilizing open-collector output circuitry (\"13\").\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit Number Allocation\u003c\/strong\u003e: Consumes 1 Special I\/O Unit slot address (set via the front-panel rotary switch from 0 to 95).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCore Physical and Electrical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCJ1W-NC113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Type\u003c\/td\u003e\n\u003ctd\u003eCJ1 Special I\/O Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eOpen-loop control via pulse train \/ Open-collector output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Control Axes\u003c\/td\u003e\n\u003ctd\u003e1 axis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Current Consumption (5 VDC)\u003c\/td\u003e\n\u003ctd\u003e0.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Requirement (24 VDC)\u003c\/td\u003e\n\u003ctd\u003eNone (Internal 5 VDC backplane bus power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit Weight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 130 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 75 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Integration \u0026amp; Deterministic I\/O Bus Execution\u003c\/h3\u003e\n\u003cp\u003eThe module communicates directly across the CJ-series local backplane bus, transferring control words, target positioning addresses, and pulse frequency profiles between CPU memory and hardware registers. High-density I\/O routing prevents firmware flash buffer underruns during fast acceleration curves. Internal field-effect isolation protects logic circuitry from electrical noise on the open-collector output lines.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron CJ1W-NC113 Single-Axis Position Control Unit\u003c\/li\u003e\n\u003cli\u003e1 x High-density 18-pin terminal block connector assembly\u003c\/li\u003e\n\u003cli\u003e1 x Hardware installation sheet and panel earth strap guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControl Panel Installation Practices\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Slot Alignment\u003c\/strong\u003e: Power off the rack before inserting the module into the CJ-series backplane. Engage upper and lower mounting catches until locked.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen-Collector Shielding\u003c\/strong\u003e: Route output pulse and direction cables in shielded twisted-pair wire, segregated from 230 VAC\/480 VAC motor power lines by at least 200 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocol\u003c\/strong\u003e: Connect the drain wire of shielded cables to a single-point panel ground with a ground impedance lower than 100 ohms.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eExternal Power Termination\u003c\/strong\u003e: Ensure external power supplies powering pulse collector loops do not exceed 24 VDC voltage parameters to avoid thermal damage to collector transistors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the unit address configured on the module hardware?\u003c\/p\u003e\n\u003cp\u003eSet the front-panel rotary switch to an unallocated number between 0 and 95 prior to powering on the system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the CJ1W-NC113 require an external 24 VDC power supply to operate internal logic?\u003c\/p\u003e\n\u003cp\u003eNo. The internal logic draws 0.25 A directly from the 5 VDC PLC backplane supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output signal configuration is supported by this hardware?\u003c\/p\u003e\n\u003cp\u003eThe unit features open-collector outputs suitable for driving line receivers or optocouplers on motor drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this unit be removed while the CJ-series PLC CPU is running?\u003c\/p\u003e\n\u003cp\u003eNo. Hot-swapping Special I\/O modules on a live CJ1 backplane will cause a bus fault and stop system execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the output pulse frequency command exceeds hardware limits?\u003c\/p\u003e\n\u003cp\u003eThe module flags an instruction error register in PLC memory and inhibits pulse transmission to the drive interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs differential line driver wiring supported on the output terminal?\u003c\/p\u003e\n\u003cp\u003eNo. The CJ1W-NC113 is limited to open-collector switching. Use differential units for long-distance signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many unit numbers does the CJ1W-NC113 consume in memory allocation?\u003c\/p\u003e\n\u003cp\u003eThe module consumes exactly 1 Special I\/O unit number within the PLC allocation table.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable length restriction applies to the open-collector outputs?\u003c\/p\u003e\n\u003cp\u003eKeep pulse command cabling under 2 meters to limit signal degradation and electromagnetic noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306659627181,"sku":"CJ1W-NC113","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/CJ1W-NC113_1.jpg?v=1788156364","url":"https:\/\/www.maxwellplc.com\/ru\/products\/cj1w-nc113-omron-position-control-unit-cj-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}