CJ1W-MAD42 Omron Analog I/O Module CJ Series
-
Dimensions: 180 x 130 x 90 mm
-
Country of origin: Japan
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for multi-channel analog signal processing in CJ Series PLC backplane architectures, the Omron CJ1W-MAD42 (CJ1W-MAD42 Analog I/O Unit) provides direct physical/electrical execution.
Signal Architecture & Channel Mapping
- I/O Capacity: Combines 4 analog inputs and 2 analog outputs within a single-slot module width.
- Signal Ranges: Configurable per channel for 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, and 4 to 20 mA.
- Conversion Parameters: Operates with a standard resolution of 1/4,000 (configurable to 1/8,000) and a conversion speed of 1 ms/point (configurable to 500 us/point).
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | CJ1W-MAD42 |
| Brand | Omron |
| Module Type | Analog I/O Unit |
| Series | CJ Series |
| Channel Configuration | 4 inputs, 2 outputs |
| Selectable Signal Ranges | 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, 4 to 20 mA |
| Conversion Resolution | 1/4,000 (Settable to 1/8,000) |
| Conversion Speed | 1 ms/point (Settable to 500 us/point) |
| System Unit Allocation | 1 unit number |
| Termination Type | Removable terminal block |
| Power Consumption | 0.58 A at 5 VDC (Internal backplane) |
| Operating Temp | 0 to 55 deg C |
| Weight | Approx. 0.150 kg |
| Shipping Weight | 0.2 kg |
| Shipping Dimensions | Approx. 180 x 130 x 90 mm |
Deterministic Backplane Communications
Analog signal conversion maps directly to internal CPU memory through backplane bus communication velocity Licences without scan latency bottlenecks. Fast execution enables real-time updates across all configured channels during active control cycles. Stable memory mapping and firmware flash compatibility ensure continuous conversion stability across various CJ Series rack configurations.
Standard Package Contents
- 1 x Omron CJ1W-MAD42 Analog I/O Module
- 1 x Removable Terminal Block Assembly
- 1 x Hardware Instruction Sheet
Wiring & Installation Instructions
- Slot Placement: Slide the module into the target CJ Series CPU or expansion rack slot until upper and lower latches lock into position.
- Terminal Wiring: Secure field wires using twisted-pair shielded cables to prevent signal noise on low-voltage analog inputs and current outputs.
- Shield Grounding: Connect cable shielding to a dedicated functional earth (100 ohm max resistance) at the module end only to prevent ground loops.
- Range Selection: Set input/output DIP switches and CPU memory allocation words to match field instrument signal ranges prior to powering the unit.
Technical Questions & Answers
-
What analog voltage and current ranges can be set on individual channels?
Each input and output channel independently supports ranges of 1 to 5 V, 0 to 5 V, 0 to 10 V, -10 to 10 V, and 4 to 20 mA.
-
What are the selectable resolution modes for analog-to-digital conversion?
The default resolution is 1/4,000 of full scale, which can be configured through system software settings to 1/8,000 high-resolution mode.
-
What is the signal conversion rate per channel on this unit?
Standard conversion time is 1 ms per point, which can be accelerated down to 500 us per point by modifying memory configuration settings.
-
How many unit numbers does this analog module allocate on the system rack?
The module occupies 1 unit number within the Special I/O Unit address space on the host CPU controller backplane.
-
What amount of current does the module draw from the 5 VDC logic bus?
The hardware consumes 0.58 A (580 mA) from the internal 5 VDC system backplane power rail during standard operational states.
-
Can the terminal block be removed without disconnecting individual field wires?
Yes, the front terminal block is fully removable, permitting module replacement without disturbing existing wiring runs.
-
Is hot-swapping permitted for this module during active PLC scan cycles?
No, system backplane power must be isolated prior to removing or inserting the unit to avoid communication errors and hardware damage.
-
What type of cabling is required to maintain conversion accuracy?
Twisted-pair shielded cables must be utilized for all analog signals to prevent electrical noise interference from affecting accuracy.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.