{"product_id":"ci867k01-3bse043660r1-abb-communication-modules-ac-800m","title":"CI867K01 3BSE043660R1 ABB Communication Modules AC 800M","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe ABB CI867K01, identified by part number 3BSE043660R1, represents the specialized Ethernet communication interface engineered for the ABB AC 800M controller series. This hardware kit acts as the primary gateway for Modbus TCP integration, enabling the Distributed Control System (DCS) to communicate bi-directionally with a wide spectrum of third-party field instrumentation, including variable frequency drives (VFDs), intelligent power meters, and external PLC logic controllers.\u003c\/p\u003e\n\u003cp\u003eIn modern process automation, the ability to consolidate data from heterogeneous devices into a single control plane is critical. The CI867K01 facilitates this by providing high-speed, deterministic data acquisition. By bridging the gap between standard Ethernet infrastructure and proprietary control architectures, it allows system engineers to maintain a streamlined network hierarchy while ensuring that critical operational parameters are updated with sub-millisecond precision. Unlike standard industrial gateways, this unit is built to endure the high-traffic environments characteristic of large-scale manufacturing, power distribution, and water treatment plants, where signal latency or packet loss could compromise process safety and stability.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI867K01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePart Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE043660R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 800M\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus TCP (Master and Slave)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePort Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x RJ45 Ethernet Ports\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Transfer Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10\/100 Mbps (Auto-negotiating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTP867 Baseplate Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.44 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18.6 x 6.8 x 12.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 deg C to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (via backplane)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eModel Configuration Explanation\u003c\/h3\u003e\n\u003cp\u003eThe CI867K01 kit is a comprehensive package designed for immediate deployment into an existing AC 800M rack structure. It consists of two primary physical components:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCI867 Base Unit: The intelligent communication processing engine that handles the protocol stack and I\/O mapping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTP867 Baseplate: The mechanical interface that provides the electrical connection to the system backplane and power distribution bus.\u003c\/p\u003e\n\u003cp\u003eThe \"K01\" suffix signifies that the module is delivered as a complete kit, eliminating the need for separate procurement of the mounting hardware and facilitating faster commissioning cycles in time-sensitive maintenance scenarios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cp\u003eThe versatility of the Modbus TCP interface allows the CI867K01 to be deployed across diverse industrial landscapes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Generation: Integrating boiler control systems and turbine supervisory instrumentation with the main DCS.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical Processing: Interfacing with smart valves, flow meters, and analytical sensors to monitor process chemistry in real-time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater \u0026amp; Wastewater: Monitoring remote pumping stations and linking disparate PLC networks to a central AC 800M controller for unified data management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRenewable Energy: Managing solar inverter arrays or wind turbine converters by polling critical performance variables through Modbus registers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe CI867K01 is purpose-built for the ABB AC 800M controller family. It is fully integrated with the 800xA Control Builder environment. This ensures that engineers can configure communication blocks (Modbus blocks) directly within the logic editor, significantly reducing the engineering hours required to map registers and debug communication faults. The module is also backward compatible with older revisions of the AC 800M processor modules, making it an excellent choice for system lifecycle extensions and legacy hardware modernization.\u003c\/p\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePre-Installation Check: Inspect the TP867 baseplate pins for any mechanical deformation before seating the CI867 unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Procedure: Mount the TP867 baseplate securely onto the DIN rail or backplane assembly, ensuring the grounding lug is firmly connected to the cabinet earth bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Seating: Carefully align the CI867 base unit with the TP867 connector. Press down evenly until the mechanical latch engages firmly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNetwork Cabling: Utilize high-quality, shielded Cat5e or Cat6 Ethernet cabling to connect to the RJ45 ports. Avoid excessive cable strain near the port connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAddressing: Configure the IP address, subnet mask, and gateway settings through the 800xA engineering workstation before powering the network segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh Node Density: Supports up to 70 slave devices per interface, significantly reducing the requirement for multiple communication cards in large network layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimultaneous Role Capability: The module can operate as a Modbus Master and a Slave concurrently, offering unmatched flexibility for complex data concentration tasks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVisual Diagnostics: Integrated diagnostic LEDs provide real-time status updates on communication integrity, link status, and protocol-level errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReliability: Designed with industrial-grade components to provide consistent performance in environments prone to heat and EMI, consistent with ABB’s long-term quality standards for the AC 800M platform.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eABB CI867K01 (3BSE043660R1) Modbus TCP Interface Kit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eKit Includes: CI867 communication module, TP867 baseplate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRecommended accessories: Shielded RJ45 patch cables, redundant power supply units (for high-availability configurations).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the CI867K01 support redundant communication lines?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the dual-port Ethernet design allows for network redundancy, which ensures that if one cable or switch fails, the control system maintains communication continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this module to communicate with non-ABB devices?\u003c\/p\u003e\n\u003cp\u003eA: Absolutely. The Modbus TCP protocol is an industry-standard open protocol. The CI867K01 acts as a transparent bridge, allowing you to interface with any Modbus-compliant VFD, PLC, or power meter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the CI867K01 hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: While the module is designed for easy replacement, it is strongly recommended to follow standard safety protocols and refer to your system manual regarding DCS backplane power removal before hot-swapping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How many Modbus slaves can one CI867K01 handle?\u003c\/p\u003e\n\u003cp\u003eA: The module is optimized for large networks and can support up to 70 slave devices, provided that the polling cycle times are configured appropriately to manage bandwidth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What software is required to configure this module?\u003c\/p\u003e\n\u003cp\u003eA: Configuration is handled via the ABB 800xA Control Builder software. It includes pre-defined function blocks for Modbus TCP, making register mapping intuitive for engineers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module provide isolation from the backplane?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the interface design includes electrical isolation to protect the AC 800M backplane and processor from surges or noise introduced through the Ethernet field network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the module work without the TP867 baseplate?\u003c\/p\u003e\n\u003cp\u003eA: No. The TP867 baseplate is essential for providing both the mechanical mounting and the necessary electrical bus connections to the AC 800M rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the benefit of Modbus Master and Slave roles?\u003c\/p\u003e\n\u003cp\u003eA: This capability allows the module to act as a Master to poll field sensors while simultaneously acting as a Slave to share data with a higher-level supervisory or data-logging system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I troubleshoot communication errors with this module?\u003c\/p\u003e\n\u003cp\u003eA: Start by checking the onboard LED status indicators. Detailed diagnostic buffers are also available within the 800xA Control Builder software to pinpoint specific register or protocol faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231165800621,"sku":"3BSE043660R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-ci867k01-3bse043660r1-modbus-tcp-interface-kit-p2fvl5dodx3_0e20e71d-9c8b-46c1-b8ab-58d1f96eca75.jpg?v=1762942225","url":"https:\/\/www.maxwellplc.com\/ru\/products\/ci867k01-3bse043660r1-abb-communication-modules-ac-800m","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}