{"product_id":"ci801-3bse022366r1-abb-communication-interfaces-s800-i-o","title":"CI801 3BSE022366R1 ABB Communication Interfaces S800 I\/O","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB CI801 3BSE022366R1\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCI801\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication Interface, operates as a dedicated hardware component for PROFIBUS DP-V1 network integration within S800 I\/O platforms. This module provides direct physical execution of cyclic data exchange and acyclic configuration commands between the network master and distributed I\/O stations.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe CI801 (3BSE022366R1) serves as a Fieldbus Communication Interface (FCI). It manages up to 12 S800 I\/O modules, handling local data collection, supervision, and Output Set as Predetermined (OSP) states within the cluster.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI801 3BSE022366R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.26 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e13.5 x 9.0 x 5.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePROFIBUS DP-V1 (up to 12 Mbit\/s)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eABB Industrial Control \u0026amp; Drive Communication\u003c\/h3\u003e\n\u003cp\u003eThe CI801 utilizes deterministic backplane bus communication velocity to interface with the S800 I\/O backplane. It supports I\/O density scaling and firmware flash compatibility, allowing for protocol-level adjustments and diagnostic enhancements. The module provides seamless integration with Profinet and EtherNet\/IP deterministic networks when used in broader control architectures, ensuring that data packets are processed with minimal latency and high synchronization accuracy across the fieldbus.\u003c\/p\u003e\n\u003ch3\u003e## Ordering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCI801 3BSE022366R1 PROFIBUS DP-V1 Interface module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e9-pin D-sub connector for PROFIBUS network cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation for S800 I\/O system integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the CI801 onto a standard 35 mm DIN rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the module is properly seated and locked into the S800 I\/O backplane connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the PROFIBUS network cable to the 9-pin D-sub port. Ensure cable shielding is grounded according to standard PROFIBUS installation practices to mitigate electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply 24 V DC power to the module supply terminals, verifying correct polarity to avoid internal electrical faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the CI801 support Hot Configuration In Run (HCIR)?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module allows for the addition or replacement of I\/O modules and parameter adjustments without requiring a system-wide shutdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How many I\/O modules can be connected to one CI801?\u003c\/p\u003e\n\u003cp\u003eA: The CI801 supports a cluster of up to 12 S800 I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the PROFIBUS baud rate configurable?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The CI801 supports automatic baud rate detection up to a maximum of 12 Mbit\/s.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can HART device data be transmitted through this module?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The CI801 supports HART pass-through, enabling remote instrument calibration and asset management via the PROFIBUS network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module provide galvanic isolation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. It includes internal galvanic isolation circuitry to protect the backplane electronics from fieldbus-related surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How are fail-safe states handled?\u003c\/p\u003e\n\u003cp\u003eA: The module manages Output Set as Predetermined (OSP) functions, ensuring I\/O states transition to defined values upon loss of communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I update the firmware in the field?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The CI801 supports firmware updates to maintain compatibility with updated system requirements and network protocols.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the module compatible with the 800xA system?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is designed for integration into the ABB 800xA Distributed Control System as an S800 I\/O interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231162982573,"sku":"3BSE022366R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-ci801-3bse022366r1-profibus-dp-vi-communication-interface-module-1k4mipdxi53_229176f7-5ef7-4675-96f0-ec46800f2f72.jpg?v=1762942207","url":"https:\/\/www.maxwellplc.com\/ru\/products\/ci801-3bse022366r1-abb-communication-interfaces-s800-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}