{"product_id":"bently-nevada-pwa-123447-01-sampler-board-tdxnet-series","title":"Bently Nevada PWA 123447-01 Sampler Board TDXnet Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada PWA123447-01\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTDXnet\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSampler Board utilized to execute high-resolution static, orbit, and spectrum data sampling across TDXnet Series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Traceability and Spare Identifiers\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTDXnet\u003c\/strong\u003e: Transient data exchange network hardware platform designation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePWA123447-01\u003c\/strong\u003e: Primary printed wire assembly part number for the sampler circuit board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries2150\/2155\u003c\/strong\u003e: Associated base system series instrumentation compatibility matrix.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBoard Parameter Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePWA123447-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.3 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 x 19.1 x 10.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDerived from backplane rail with immediate power loss recovery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Port\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated Ethernet link interface to Data Manager hardware\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Buffers\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 independent startup\/shutdown transient buffers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-resolution conversion for static, orbit, and spectrum tracks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransient Tracking and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe sampling matrix captures raw input data from front-end channels without distorting calibrated eddy-current probe scaling metrics. During machine startup and shutdown events, the board tracks rapid rotor dynamics variations across two independent hardware buffers. Continuous processing validation preserves gap voltage validation (-10 VDC targets) monitoring alignment, while integrated backplane filter circuits enforce cross-talk suppression between high-speed tracking channels.\u003c\/p\u003e\n\u003ch3\u003eShipment Box Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada PWA123447-01 TDXnet Sampler Board\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Static Shielding Protective Bag\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Slide and Communication Setup\u003c\/h3\u003e\n\u003ch3\u003eBackplane Slot Insertion\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the board edges with the chassis guide rails inside the TDXnet monitoring enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlide the board forward until the rear pin connectors lock into the passive backplane bus assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication Cable Routing\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnect an industrial category Ethernet cable to the front panel interface port to establish a direct link to the Data Manager.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute all communication lines away from adjacent primary power loops to shield data packets from inductive noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the immediate recovery from power loss function perform during an unexpected electrical drop?\u003c\/p\u003e\n\u003cp\u003eInternal high-speed capacitors maintain register state data, allowing the circuit to resume active sampling immediately upon power restoration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific sampler board configuration support hot-swap extraction while the slot is active?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swap operations are completely restricted; isolate the main sub-rack power bus before unseating or replacing this board asset.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat exact memory boundaries limit the two independent startup\/shutdown storage blocks?\u003c\/p\u003e\n\u003cp\u003eThe hardware contains two isolated memory zones configured to lock transient data during machine status transitions without overwriting passive logs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat total physical envelope values restrict the unboxed weight and shipping parameters?\u003c\/p\u003e\n\u003cp\u003eThe internal assembly weighs 0.3 kg net within maximum package dimension limits of 2.5 x 19.1 x 10.2 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does backplane noise affect the high-resolution static, orbit, and spectrum data tracking?\u003c\/p\u003e\n\u003cp\u003eThe board features dedicated electronic filtering layers that isolate conversion nodes, preserving eddy-current probe scaling accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat interface standard regulates the direct hardware data link to the Data Manager node?\u003c\/p\u003e\n\u003cp\u003eThe data path uses a standard IEEE 800.3 Ethernet connection layer to manage fast spectrum data file transfers to the host PC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy must field engineers ensure the chassis grounding screws are torqued down completely?\u003c\/p\u003e\n\u003cp\u003eLoose faceplate grounding paths create common-mode noise, which impairs the cross-talk suppression capabilities of the transient channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this hardware be deployed inside legacy 7200 series monitoring racks using adapters?\u003c\/p\u003e\n\u003cp\u003eNo, the physical interface pins and TDXnet sampling logic are incompatible with older backplane line standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026846470317,"sku":"123447-01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/123447-01_353.jpg?v=1782722415","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-pwa-123447-01-sampler-board-tdxnet-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}