{"product_id":"bently-nevada-990-04-70-03-00-990-991-series-vibration-transmitter","title":"Bently Nevada 990-04-70-03-00 990\/991 Series Vibration Transmitter","description":"\u003cp\u003eConfigured for radial vibration monitoring in rotating machinery loops, the \u003cstrong\u003eBently Nevada 990-04-70-03-00\u003c\/strong\u003e (\u003cstrong\u003e990\u003c\/strong\u003e Vibration Transmitter) provides direct physical\/electrical execution. Operating as a 2-wire, loop-powered device, it accepts input from a 3300 NSv proximity probe and matching extension cable to output a proportional 4-20 mA industry-standard signal. The hardware integrates the function of a Proximitor sensor directly into the transmitter enclosure, conditioning raw eddy-current telemetry into peak-to-peak vibration amplitude engineering units for direct input to programmable logic controllers (PLCs) or distributed control systems (DCS).\u003c\/p\u003e\n\u003ch3\u003eConfiguration Options Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e990\u003c\/strong\u003e: Base model prefix designating the integrated 2-wire radial vibration transmitter platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e04\u003c\/strong\u003e: Full-scale range option selecting 0-4 mils peak-to-peak (0-100 \\mu m peak-to-peak).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e70\u003c\/strong\u003e: Dedicated system length configuration calibrated for 7.0 meters (23.0 feet) sensor loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e03\u003c\/strong\u003e: Mounting mechanical option integrating both 35 mm DIN-rail clips and bulkhead mounting screws.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Agency approval selection option signifying no certifications are required for the target environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransmitter Technical Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-04-70-03-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10.0 x 7.5 x 5.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasured Variable\u003c\/td\u003e\n\u003ctd\u003eRadial vibration (peak-to-peak amplitude)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC analog current loop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Device Interface\u003c\/td\u003e\n\u003ctd\u003e3300 NSv Proximity Probe and Extension Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTuned System Length\u003c\/td\u003e\n\u003ctd\u003e7.0 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Adjustments\u003c\/td\u003e\n\u003ctd\u003eNon-interacting zero and span potentiometers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics Port\u003c\/td\u003e\n\u003ctd\u003eCoaxial connector and non-isolated PROX OUT \/ COM terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVerification Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated Test Input pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Construction\u003c\/td\u003e\n\u003ctd\u003ePotted design for high humidity isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop-powered (4-20 mA execution range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Rotor Dynamics Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe 990-04-70-03-00 transmitter relies on calibrated eddy-current probe scaling to precisely convert target distance into linear electrical signals. To establish the precise operating point over the micro-machined target area, field technicians execute gap voltage validation (-10 VDC targets) via the non-isolated PROX OUT and COM terminal tracks or the onboard coaxial diagnostic port. The hardware utilizes embedded filtration circuitry optimized for cross-talk suppression, ensuring that high-frequency electromagnetic noise from nearby power lines does not distort the raw rotor dynamics waveforms. The continuous analog processing path delivers unattenuated peak-to-peak metrics directly to the 4-20 mA output conditioning stage.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 990-04-70-03-00 Vibration Transmitter\u003c\/li\u003e\n\u003cli\u003e2 x Pre-assembled 35 mm DIN-rail clips\u003c\/li\u003e\n\u003cli\u003e2 x Bulkhead mounting screws\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mechanical Installation Guidelines\u003c\/h3\u003e\n\u003ch3\u003eGrounding Rules\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the field wiring cable shield line to a single instrumentation clean earth ground point inside the main control cabinet block.\u003c\/li\u003e\n\u003cli\u003eIsolate the proximity probe extension cable shield from the local industrial machine housing structure to prevent ground-loop current paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWiring Constraints\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm total circuit loop resistance allows for adequate supply voltage delivery across the 2-wire current loop terminals.\u003c\/li\u003e\n\u003cli\u003eAlways match the transmitter to a certified 7.0 meter system length probe and extension assembly to preserve factory scaling accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShielding Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRoute all sensor and loop interconnect wiring through dedicated, grounded metal conduits to optimize high-frequency noise rejection.\u003c\/li\u003e\n\u003cli\u003eSeparate the transmitter signal cables from AC power distribution lines by a minimum spacing boundary of 300 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTuning \u0026amp; Setup Controls\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAccess the non-interacting zero and span potentiometers underneath the transmitter label for localized loop calibration adjustments.\u003c\/li\u003e\n\u003cli\u003eUtilize the built-in Test Input pin with an external function generator to simulate target vibration profiles and verify downstream loop response.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the hot-swap restriction when replacing a 990 transmitter on a live industrial asset?\u003c\/p\u003e\n\u003cp\u003eA: The associated control channel must be placed in manual bypass mode at the PLC or DCS level prior to terminal disconnection to prevent sudden loop dropouts from triggering emergency machinery trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What electrical power load does this unit draw from an internal backplane rack?\u003c\/p\u003e\n\u003cp\u003eA: The transmitter draws 0 mA of internal instrument backplane power, functioning strictly as a passive, loop-powered device driven by external power supply loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the fail-safe channel switching delay if the 3300 NSv probe cable is severed?\u003c\/p\u003e\n\u003cp\u003eA: The transmitter drives its current loop below 3.6 mA or above 22 mA within milliseconds, adding 0 ms of processing delay to the physical fault state propagation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are software firmware updates required to maintain compatibility with updated PLC architectures?\u003c\/p\u003e\n\u003cp\u003eA: No, the transmitter utilizes a fully analog signal conditioning architecture, rendering it completely independent of digital software microcode changes or control system firmware revisions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What degree of electrical isolation is provided between the housing frame and the inner sensor circuit?\u003c\/p\u003e\n\u003cp\u003eA: The internal transducer measurement circuit is electrically isolated from the metal baseplate to protect the integrity of the sensor loop from machine casing noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the dynamic diagnostic port affect the primary 4-20 mA current loop performance?\u003c\/p\u003e\n\u003cp\u003eA: The coaxial port and PROX OUT terminals provide buffered AC vibration signals for analyzer tools without causing any disruption or dropouts on the main loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this unit transmit phase vector angles for high-speed machinery balance diagnostics?\u003c\/p\u003e\n\u003cp\u003eA: No, the 4-20 mA output provides only overall peak-to-peak amplitude metrics and cannot track phase indicators or communicate with plant-wide diagnostic suites.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What protection does the transmitter housing provide against high-humidity operating environments?\u003c\/p\u003e\n\u003cp\u003eA: The unit features a fully potted inner electronics cavity that seals out moisture, allowing stable execution in extreme process applications up to 100 percent humidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025229729965,"sku":"990-04-70-03-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/990_c867957f-3e0a-4570-b68e-1a5435c006a6.jpg?v=1783783999","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-990-04-70-03-00-990-991-series-vibration-transmitter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}