{"product_id":"bently-nevada-330194-15-25-50-05-proximity-probe-3300-xl-8-mm","title":"Bently Nevada 330194-15-25-50-05 Proximity Probe 3300 XL 8 mm","description":"\u003cp\u003eConfigured for high-temperature vibration and position measurements in rotating machinery, the \u003cstrong\u003eBently Nevada 330194-15-25-50-05\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330194-15-25-50-05\u003c\/strong\u003e Proximity Probe, provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eModel Matrix and Suffix Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Series\u003c\/strong\u003e: 330194 (3300 XL 8 mm Extended Temperature Range Proximity Probe)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnthreaded Length\u003c\/strong\u003e: 15 (150 mm unthreaded length option)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCase Length\u003c\/strong\u003e: 25 (250 mm overall case length option)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Cable Length\u003c\/strong\u003e: 50 (5.0 meters \/ 16.4 feet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgency Approvals\u003c\/strong\u003e: 05 (CSA, ATEX, IECEx certified)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330194-15-25-50-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e35 x 24 x 2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive Component (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Specification\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 with stainless steel armor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm to 5.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eDesigned for extreme thermal environments, this proximity probe preserves precise eddy-current probe scaling to ensure linear voltage output corresponding to shaft displacement. During commissioning, gap voltage validation targets a nominal -10 VDC baseline when interfaced with a matched 3300 XL Proximitor sensor. Furthermore, robust coaxial shielding combined with stainless steel armor execution ensures cross-talk suppression and isolates the high-frequency carrier signal from electromagnetic interference inside heavy industrial enclosures.\u003c\/p\u003e\n\u003ch3\u003eStandard Scope of Supply\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 330194-15-25-50-05 Extended Temperature Range Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x M10 x 1 Mounting Locknut Set\u003c\/li\u003e\n\u003cli\u003e1 x Hazardous Area Certification Documentation Insert\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation and Mounting Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Engagement Limits\u003c\/strong\u003e: Ensure the mounting bracket hole is free of debris and that maximum thread engagement of the M10 x 1 probe case does not exceed 15 mm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTorque Specifications\u003c\/strong\u003e: Tighten the probe case to a recommended torque of 5.1 N m (45 in lb), ensuring the limit does not exceed 7.3 N m (65 in lb) to avoid thread stripping.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransductor Separation\u003c\/strong\u003e: Maintain a minimum side clearance of 25 mm (1.0 in) between adjacent transducer tips to prevent electromagnetic cross-talk interference during multi-probe setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the designated cable length for this probe assembly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe total integrated cable length is 5.0 meters (16.4 feet) as specified by the 50 suffix code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat thread size is utilized on the probe case housing?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe probe features an M10 x 1 metric threading profile equipped with protective stainless steel armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operating temperature threshold for this ETR probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor functions within an ambient range of -52 deg C to +100 deg C while supporting extended tip thermal ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this passive sensor require an external DC power source?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the proximity probe relies entirely on the radio frequency excitation signal supplied by the connected Proximitor sensor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended installation torque for the probe case?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe recommended installation torque is 5.1 N m (45 in lb) with a hard maximum cap of 7.3 N m (65 in lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow should cross-talk be prevented between multiple probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA minimum spatial separation of 25 mm (1.0 in) must be maintained between adjacent transducer tips during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat hazardous location certifications are included with this part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 05 suffix confirms compliance with CSA, ATEX, and IECEx hazardous area certification standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the verified shipping weight of the packed unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe total gross weight including standard transit packaging is 0.24 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025671835821,"sku":"330194-15-25-50-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian-58_9f8b028f-90b3-4a44-8921-ea798fc7e180.jpg?v=1783655690","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-330194-15-25-50-05-proximity-probe-3300-xl-8-mm","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}