{"product_id":"bently-nevada-330104-03-06-05-02-00-3300-xl-8mm-proximity-probes","title":"Bently Nevada 330104-03-06-05-02-00 3300 XL 8mm Proximity Probes","description":"\u003cp\u003eThe 330104-03-06-05-02-00, also cataloged as the 3300 XL 8mm Proximity Probes, operates as a dedicated hardware component for signal processing or control execution within industrial automation architectures. This sensor system utilizes eddy current technology to facilitate non-contact displacement monitoring. By maintaining a constant gap measurement between the probe tip and the target material, the system transmits precise vibration and axial position data to monitoring instrumentation. The unit is engineered for reverse mount applications, requiring installation from the internal side of the machine housing, ensuring integration into critical rotating equipment monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330104\u003c\/strong\u003e: 3300 XL 8mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e03\u003c\/strong\u003e: 3\/8-24 UNF threads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e06\u003c\/strong\u003e: 0.6 inch case length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: 0.5 meter (1.6 feet) total length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Miniature coaxial ClickLoc connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency Approval (Standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data Overview\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-03-06-05-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Sensitivity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 304 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Processing and Vibration Analysis\u003c\/h3\u003e\n\u003cp\u003eThe 330104-03-06-05-02-00 is calibrated for eddy current probe scaling within the 3300 XL transducer system. The system requires a -24 VDC supply provided by the Proximitor sensor. Proper operation necessitates monitoring the gap voltage, typically set to -10 VDC mid-range to ensure linear response for rotor dynamics analysis. This sensor provides the fundamental input for detecting shaft orbital motion, axial displacement, and radial vibration. The integrity of the signal processing chain relies on the ClickLoc connector, which maintains low contact resistance and minimizes signal attenuation in environments characterized by high-frequency machinery oscillation.\u003c\/p\u003e\n\u003ch3\u003eDelivery Package Details\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330104-03-06-05-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation and Setup Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Product Certification and Conformity Documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Site Integration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the probe is threaded into the machine housing using the provided 3\/8-24 UNF threads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply a torque of 5.6 Nm to secure the probe, ensuring the housing remains free from structural stress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCable Routing and Shielding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute coaxial cables through grounded metallic conduits to minimize electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain the integrity of the ClickLoc connector by ensuring no tension is applied to the cable junction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperational Clearance\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eObserve a minimum radial clearance of 3 times the probe tip diameter from surrounding metallic obstructions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the gap voltage using a digital voltmeter during the final alignment process to ensure the sensor is centered within its linear range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOperational FAQ\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 330104 probe require calibration with the extension cable?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 330104-03-06-05-02-00 is calibrated as a system including the probe, extension cable, and Proximitor sensor.\u003c\/p\u003e\n\u003cp\u003eQ: Can this probe be used in high-pressure environments?\u003c\/p\u003e\n\u003cp\u003eA: The PPS tip and stainless steel case are designed to withstand high-pressure fluid environments common in industrial compressors.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc connector provides a vibration-resistant, repeatable electrical connection that maintains signal integrity.\u003c\/p\u003e\n\u003cp\u003eQ: How is the probe grounded?\u003c\/p\u003e\n\u003cp\u003eA: The probe case is electrically insulated from the machine housing via the mounting bracket to prevent ground loops.\u003c\/p\u003e\n\u003cp\u003eQ: Can I replace the probe without replacing the Proximitor?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided the new probe has the same physical and electrical specifications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum cable length supported for this model?\u003c\/p\u003e\n\u003cp\u003eA: This model includes a 0.5 meter integral cable; system length is determined by the total length including the specific extension cable chosen.\u003c\/p\u003e\n\u003cp\u003eQ: How does the probe detect shaft vibration?\u003c\/p\u003e\n\u003cp\u003eA: It measures the change in eddy current density as the gap between the probe tip and the shaft surface fluctuates.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761984173,"sku":"330104-03-06-05-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-03-06-05-02-00-proximity-probes-fcvxhtiixh3.jpg?v=1766977049","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-330104-03-06-05-02-00-3300-xl-8mm-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}