{"product_id":"bently-nevada-330103-00-08-10-02-00-3300-xl-8-mm-series-proximity-probe","title":"Bently Nevada 330103-00-08-10-02-00 3300 XL 8 mm Series Proximity Probe","description":"\u003cp\u003eConfigured for displacement and vibration measurements, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-00-08-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution. This non-contacting transducer measures the gap between the probe tip and a conductive target, converting shaft position changes into an electrical signal managed by a 3300 XL Proximitor Sensor. It serves as the primary inductive interface for monitoring radial vibration and axial position in rotating machinery.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330103\u003c\/strong\u003e: 3300 XL 8 mm Proximity Probe, M10 x 1 thread.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded length option (0.0 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e08\u003c\/strong\u003e: Overall case length (0.8 in).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total cable length (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector and cable option (Miniature coaxial ClickLoc connector with connector protector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency approval option (No approvals).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-00-08-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.0 cm x 20.0 cm x 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eEddy-current probe scaling is factory-calibrated for AISI 4140 steel targets. Field deployment requires gap voltage validation (-10 VDC targets) at the Proximitor output terminal to center the probe within its linear sensing range. Accurate rotor dynamics analysis depends on this precise electrical alignment. Furthermore, maintaining cross-talk suppression by ensuring sufficient physical distance between adjacent sensors is mandatory to prevent electromagnetic interference and signal errors in multi-channel measurement setups.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330103-00-08-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 M10 x 1 Hex Jam Nuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Connector Protector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Technical Installation Document\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread the probe into the mounting bracket, ensuring at least 5 full threads of engagement to provide structural stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the sensor gap to reach the required -10 VDC bias voltage, then secure the jam nuts to a torque of 5.1 N-m (45 in-lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute coaxial cables through dedicated grounded conduits to isolate them from high-voltage AC lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not exceed the minimum bend radius of 25.4 mm (1.0 in) to prevent internal dielectric damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the target gap voltage for system calibration?\u003c\/p\u003e\n\u003cp\u003eThe probe must be gapped until the Proximitor outputs -10 VDC, which corresponds to the linear center of the 80 mil sensing range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be connected to a non-XL series Proximitor?\u003c\/p\u003e\n\u003cp\u003eNo, 3300 XL probes are specifically impedance-matched to 3300 XL series Proximitor modules. Mixing series will result in measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe cable length modifiable in the field?\u003c\/p\u003e\n\u003cp\u003eNo, the cable is an integral part of the tuned system impedance. Modifying or splicing the cable will invalidate the factory calibration and scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the probe tip protected?\u003c\/p\u003e\n\u003cp\u003eThe probe includes a ClickLoc connector protector to prevent contamination of the coaxial mating surfaces in industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe tip is installed too close to the target?\u003c\/p\u003e\n\u003cp\u003eThe sensor output will reach the negative supply saturation point, potentially causing \"Not OK\" status in the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe be used at temperatures above 177 deg C?\u003c\/p\u003e\n\u003cp\u003eNo, exceeding the maximum operating temperature will cause failure of the probe's internal potting and degradation of the sensing coil.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eThe sensor can be physically replaced during operation, but the connected Proximitor will register a temporary channel fault alarm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of magnetic materials on the probe?\u003c\/p\u003e\n\u003cp\u003eThe probe is calibrated for AISI 4140 steel; using other materials will require a non-linear correction factor applied in the system monitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026835656877,"sku":"330103-00-08-10-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian10_9c019667-a02a-41bb-9854-21bf7b0efabf.jpg?v=1782785470","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-330103-00-08-10-02-00-3300-xl-8-mm-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}