{"product_id":"bently-nevada-330101-02-12-10-02-00-8-mm-proximity-probe-3300-xl-series","title":"Bently Nevada 330101-02-12-10-02-00 8 mm Proximity Probe 3300 XL Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-02-12-10-02-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330101-02-12-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 mm Proximity Probe, operates as a dedicated hardware component for sensing shaft radial vibration and position within machinery protection and condition monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eConfiguration and Model Composition\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 330101 (3300 XL 8 mm Probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThread Size: 3\/8-24 UNF\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eArmor: Not included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnthreaded Length: 0.2 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCase Length: 1.2 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal Length: 1.0 meter (3.3 feet)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: Miniature coaxial ClickLoc connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAgency Approval: Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Technical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-02-12-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.6 x 1.4 x 119 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePowered by Proximitor Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Signal Validation\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL 8 mm probe system utilizes a high-frequency carrier signal to measure the gap between the probe tip and the observed conductive target. Accurate scaling requires a target material consistent with AISI 4140 steel. Field technicians must verify the gap voltage using a digital multimeter; the target operating range is typically centered at -10 VDC. Any deviation from the linear range or evidence of cross-talk from adjacent probes must be mitigated by maintaining proper physical separation and ensuring the probe cable is routed away from high-voltage AC lines to maintain signal integrity for rotor dynamics analysis.\u003c\/p\u003e\n\u003ch3\u003eScope of Delivery\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 unit of 330101-02-12-10-02-00 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 unit of standard Miniature coaxial ClickLoc connector (integrated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Best Practices\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Mounting: Ensure the probe is mounted in a rigid bracket to prevent vibration-induced signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThread Engagement: Confirm that the probe is locked in place with the provided jam nut to maintain the established gap distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Ensure the coaxial shield is connected to the common ground at the monitor or the terminal block to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eClearance: Maintain a minimum clear zone around the probe tip to avoid influence from surrounding housing geometry, which can distort the linear output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Queries\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the 3300 XL probe system?\u003c\/p\u003e\n\u003cp\u003eThe probe converts physical gap changes into an electrical signal, which is then processed by a Proximitor sensor to provide continuous monitoring of shaft vibration and displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in high-temperature environments?\u003c\/p\u003e\n\u003cp\u003eYes, the probe is rated for operation up to 177 deg C, provided the coaxial cable and connector are also rated for the specific thermal environment of the application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the ClickLoc connector?\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector provides a secure, vibration-resistant connection for the coaxial cable, ensuring consistent electrical contact without the need for traditional manual locking mechanisms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the probe gap be set during commissioning?\u003c\/p\u003e\n\u003cp\u003eThe probe should be positioned such that the DC output voltage is at the midpoint of the linear range, usually -10 VDC, relative to the shaft centerline at operating speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require specific calibration for different materials?\u003c\/p\u003e\n\u003cp\u003eYes, the standard calibration is optimized for AISI 4140 steel. If the target material differs, a scale factor adjustment or custom calibration curve must be applied.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs it necessary to use armored cabling for this model?\u003c\/p\u003e\n\u003cp\u003eThe armor is optional for mechanical protection. If the installation environment involves debris or high mechanical stress, armor should be specified in the order.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unthreaded length affect installation?\u003c\/p\u003e\n\u003cp\u003eThe 0.2 in unthreaded length determines the minimum clearance required from the mounting surface to the probe tip. Ensure the bracket thickness does not interfere with the active sensing zone.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use a longer cable than 1.0 meter?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL system is tuned for specific cable lengths (5m or 9m total length). Using a length inconsistent with the system design will degrade the frequency response and accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025224126637,"sku":"330101-02-12-10-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xianxian_45_d98d09ae-3acc-452e-8073-7712fe814814.jpg?v=1783582830","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-330101-02-12-10-02-00-8-mm-proximity-probe-3300-xl-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}