{"product_id":"bently-nevada-330101-00-50-10-02-00-3300-xl-8-mm-proximity-probe-3300-xl","title":"Bently Nevada 330101-00-50-10-02-00 3300 XL 8 mm Proximity Probe 3300 XL","description":"\u003cp\u003eConfigured for precise non-contact displacement and vibration monitoring in 3300 System platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-50-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction for rotary machine analysis. The probe converts mechanical motion into eddy-current-based voltage signals for processing.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: 330101-00-50-10-02-00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Type: 3300 XL 8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnthreaded Length: 00 - 0.0 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCase Length: 50 - 5.0 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal Length: 10 - 1.0 m (3.3 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: 02 - Miniature coaxial ClickLoc connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAgency Approval: 00 - Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-50-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 x 1.3 x 111 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Transducer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Transducer Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 330101 transducer system relies on eddy-current probe scaling calibrated to AISI 4140 steel. Proper installation requires gap voltage validation to ensure the signal rests at the -10 VDC target midpoint within the linear range. To ensure measurement accuracy, installers must enforce cross-talk suppression by maintaining a minimum side-view clearance of 1.5 inches (38 mm) from the probe tip. When configuring rotor dynamics measurement channels, the transducer must be isolated from mechanical noise and electromagnetic interference, particularly in high-speed machinery environments, to prevent signal distortion.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330101 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Threaded mounting nut (pre-installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaterial Compliance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the observed target is AISI 4140 steel to maintain factory-calibrated linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInstall the probe through the mounting bracket, ensuring a minimum side-view clearance of 1.5 inches (38 mm) from all metallic objects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInterference Mitigation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a minimum 1.5 inch (38 mm) separation between tips when installing multiple radial vibration probes to eliminate signal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the ClickLoc connector firmly to the extension cable, ensuring the housing provides a dust-tight seal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used for axial position measurement?\u003c\/p\u003e\n\u003cp\u003eYes. While often used for radial vibration, the probe is equally capable of measuring axial thrust position if mounted perpendicularly to a shaft shoulder.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs bench calibration required after installation?\u003c\/p\u003e\n\u003cp\u003eNo. The 3300 XL system supports complete interchangeability; as long as the components are matched within the system standard, manual bench calibration is not necessary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the effect of using a non-AISI 4140 target?\u003c\/p\u003e\n\u003cp\u003eNon-standard target materials change the eddy-current eddy-field penetration depth, resulting in non-linear voltage output and loss of accuracy relative to the probe scaling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the ClickLoc connector waterproof?\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector is designed for industrial environments but is not submersible. It should be housed within a conduit or junction box if exposed to process fluids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the probe tip protected?\u003c\/p\u003e\n\u003cp\u003eThe probe tip is constructed from high-strength polyphenylene sulfide, providing chemical and thermal resistance during standard operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe be cut to a shorter length?\u003c\/p\u003e\n\u003cp\u003eNo. The probe and cable are a matched system. Cutting the cable changes the impedance, which invalidates the calibration and degrades the high-frequency signal response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the unthreaded length option?\u003c\/p\u003e\n\u003cp\u003eThe unthreaded length allows for specific mounting depth requirements in machine casings, preventing interference between the threads and the internal mounting surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does RFI immunity compare to older models?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL system incorporates improved filtering, meeting European CE mark approvals without the need for external shielded conduits or specialized metallic housings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026629611693,"sku":"330101-00-50-10-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian8_e11c3047-81ae-4e3a-b433-8af67e743cea.jpg?v=1783585092","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-330101-00-50-10-02-00-3300-xl-8-mm-proximity-probe-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}