{"product_id":"bently-nevada-190501-12-00-02-190501-series-velocity-transducer","title":"Bently Nevada 190501-12-00-02 190501 Series Velocity Transducer","description":"\u003cp\u003eConfigured for low-frequency casing vibration velocity measurement in Bently Nevada machinery monitoring systems, the \u003cstrong\u003eBently Nevada 190501-12-00-02\u003c\/strong\u003e (\u003cstrong\u003e190501\u003c\/strong\u003e Velomitor CT Velocity Transducer) provides direct mechanical vibration signal conversion.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe 190501-12-00-02 is a Velomitor CT Velocity Transducer configured for measuring casing vibration velocity on rotating equipment with low-speed operating characteristics. The device uses a 3\/8-in 24 to M8x1 plate stud mounting interface and a MIL-C-5015 connection interface.\u003c\/p\u003e\n\u003cp\u003eThe transducer is designed for vibration measurement on cooling tower and air-cooled heat-exchanger fan assemblies operating at or above 90 RPM. It detects casing vibration velocity signals generated by fan motors, speed reducers, and rotating mechanical components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e190501-12-00-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVelocity Transducers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eVelomitor CT Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e8.3 x 3.5 x 3.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Type\u003c\/td\u003e\n\u003ctd\u003eCasing Vibration Velocity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Hardware\u003c\/td\u003e\n\u003ctd\u003ePlate Stud 3\/8-in 24 to M8x1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Interface\u003c\/td\u003e\n\u003ctd\u003eMIL-C-5015\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003eThrough 04 CSA\/NRTL\/C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransverse Response\u003c\/td\u003e\n\u003ctd\u003eLess than 5% of axial sensitivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplitude Linearity\u003c\/td\u003e\n\u003ctd\u003e+\/-2% to 63.5 mm\/s pk (2.5 in\/s pk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Limit\u003c\/td\u003e\n\u003ctd\u003e5000 g pk maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Speed Range\u003c\/td\u003e\n\u003ctd\u003e90 RPM and above\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe Velomitor CT transducer provides velocity measurement characteristics for low-frequency machinery vibration monitoring. The sensor is optimized for casing vibration analysis where mechanical imbalance, misalignment, and bearing-related vibration conditions require velocity measurement.\u003c\/p\u003e\n\u003cp\u003eUnlike eddy-current proximity measurement systems that monitor shaft displacement, the Velomitor CT measures casing vibration response directly. The transducer output supports rotor dynamics evaluation by converting mechanical vibration movement into an electrical velocity signal.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard package contents include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 190501-12-00-02 Velomitor CT Velocity Transducer\u003c\/li\u003e\n\u003cli\u003e1 x Integrated MIL-C-5015 connection interface\u003c\/li\u003e\n\u003cli\u003e1 x Plate stud mounting configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAdditional installation components may include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompatible vibration monitoring system input module\u003c\/li\u003e\n\u003cli\u003eMounting accessories according to machine installation requirements\u003c\/li\u003e\n\u003cli\u003eField wiring assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Mounting\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the transducer on a rigid machine casing surface.\u003c\/li\u003e\n\u003cli\u003eVerify the mounting interface matches the specified 3\/8-in 24 to M8x1 plate stud configuration.\u003c\/li\u003e\n\u003cli\u003eEnsure the mounting surface is clean and free from debris before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Connection\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConnect the MIL-C-5015 interface according to the vibration monitoring system wiring documentation.\u003c\/li\u003e\n\u003cli\u003eVerify signal polarity and cable termination before commissioning.\u003c\/li\u003e\n\u003cli\u003eMaintain proper cable routing away from high-current electrical conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeasurement Setup\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the sensor mounting location represents the intended casing vibration measurement point.\u003c\/li\u003e\n\u003cli\u003eCheck vibration channel configuration before collecting operational data.\u003c\/li\u003e\n\u003cli\u003eVerify signal response during initial machine operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat vibration parameter does the 190501-12-00-02 measure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transducer measures casing vibration velocity from rotating machinery and provides velocity-based vibration monitoring signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat equipment is the Velomitor CT designed for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is designed for cooling tower and air-cooled heat-exchanger fan assemblies operating at or above 90 RPM.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting interface is included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe model includes a plate stud mounting configuration from 3\/8-in 24 thread to M8x1 interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat type of electrical connection does this model use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transducer uses a MIL-C-5015 connection interface for integration with vibration monitoring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the transverse response specification?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe transverse response is less than 5% of the axial sensitivity according to the provided specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e**What is the maximum shock limit of the transducer?\u003c\/p\u003e\n\u003cp\u003eThe specified maximum shock limit is 5000 g pk for mechanical impact conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan this sensor measure shaft displacement directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The Velomitor CT measures casing vibration velocity rather than shaft position displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat vibration frequency range is this sensor intended for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe sensor is optimized for low-frequency vibration applications, including rotating equipment operating around 90 RPM and above.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025254830253,"sku":"190501-12-00-02","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/190501-00-00-003_3a54005c-d3c6-4f81-90a2-8086ea51a25f.jpg?v=1785738620","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-190501-12-00-02-190501-series-velocity-transducer","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}