{"product_id":"bently-nevada-1900-27-03-vibration-monitor-1900-series","title":"Bently Nevada 1900\/27-03 Vibration Monitor 1900 Series","description":"\u003cp\u003eConfigured for single-channel vibration signal monitoring in Bently Nevada 1900 monitoring platforms, the \u003cstrong\u003eBently Nevada 1900\/27-03\u003c\/strong\u003e (\u003cstrong\u003e1900\u003c\/strong\u003e Vibration Monitor) provides direct physical\/electrical execution for vibration measurement processing and adjustable time delay alarm output.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 1900\/27-03 Vibration Monitor is a single-channel monitoring device designed for vibration measurement applications. The unit includes adjustable time delay alarm functionality and operates from a 110 VAC power supply at 50\/60 Hz.\u003c\/p\u003e\n\u003cp\u003eThe monitor processes vibration input signals and provides alarm response based on configured vibration thresholds and delay settings. The compact enclosure design allows installation within equipment monitoring systems requiring localized vibration supervision.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eParameter\u003c\/td\u003e\n\u003ctd\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1900\/27-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVibration Monitors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e1900 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e19.8 x 16.2 x 10.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring Channel\u003c\/td\u003e\n\u003ctd\u003eSingle Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Function\u003c\/td\u003e\n\u003ctd\u003eAdjustable Time Delay Alarm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eVibration Signal Monitoring and Alarm Processing\u003c\/h3\u003e\n\u003cp\u003eThe 1900\/27-03 monitor performs vibration signal evaluation through a single monitoring channel. The adjustable time delay alarm function allows configuration of response timing before alarm activation.\u003c\/p\u003e\n\u003cp\u003eFor mechanical monitoring applications, correct sensor wiring and signal scaling are required to maintain accurate vibration evaluation. Proper grounding and cable routing practices help reduce electrical interference during vibration measurement.\u003c\/p\u003e\n\u003cp\u003eThe monitor provides a direct interface between vibration sensing circuits and alarm indication logic, allowing operators to evaluate machine vibration conditions through configured alarm states.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode Segment\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e1900\u003c\/td\u003e\n\u003ctd\u003eVibration monitor product family\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003ctd\u003eMonitor model configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e03\u003c\/td\u003e\n\u003ctd\u003eSpecific electrical and functional configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 1900\/27-03 Vibration Monitor\u003c\/li\u003e\n\u003cli\u003e1 x Factory-configured monitoring unit\u003c\/li\u003e\n\u003cli\u003e1 x Product identification label\u003c\/li\u003e\n\u003cli\u003e1 x Technical documentation package when supplied\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the 110 VAC supply voltage before energizing the monitor.\u003c\/li\u003e\n\u003cli\u003eConnect vibration input wiring according to the monitoring system configuration.\u003c\/li\u003e\n\u003cli\u003eUse appropriate grounding methods to reduce electrical noise.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKeep vibration signal cables separated from high-current power wiring.\u003c\/li\u003e\n\u003cli\u003eConfirm sensor polarity and signal direction before operation.\u003c\/li\u003e\n\u003cli\u003eInspect cable connections for mechanical stress or loose terminals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Configuration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSet alarm delay parameters according to the monitoring requirements.\u003c\/li\u003e\n\u003cli\u003eVerify alarm activation through controlled signal testing.\u003c\/li\u003e\n\u003cli\u003eConfirm the monitor response before connecting to external alarm circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the 1900\/27-03?\u003c\/p\u003e\n\u003cp\u003eThe 1900\/27-03 is a single-channel vibration monitor designed to process vibration signals and provide alarm outputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many monitoring channels are available?\u003c\/p\u003e\n\u003cp\u003eThis model provides one vibration monitoring channel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat power supply does this monitor require?\u003c\/p\u003e\n\u003cp\u003eThe 1900\/27-03 operates with a 110 VAC power supply at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the unit support alarm delay settings?\u003c\/p\u003e\n\u003cp\u003eYes. The monitor includes an adjustable time delay alarm function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 1900\/27-03 a vibration sensor?\u003c\/p\u003e\n\u003cp\u003eNo. It is a vibration monitoring device that processes input signals from compatible vibration sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat installation factor affects signal accuracy?\u003c\/p\u003e\n\u003cp\u003eProper sensor wiring, grounding, and cable routing help maintain accurate vibration signal processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the alarm timing be adjusted?\u003c\/p\u003e\n\u003cp\u003eYes. The alarm response delay can be adjusted according to system requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat should be checked before startup?\u003c\/p\u003e\n\u003cp\u003eVerify power supply, input signal wiring, alarm settings, and grounding before commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026787815597,"sku":"1900\/27-03","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/13_ef77d8a1-e48b-4f32-b7ce-e3e15f90cfaf.jpg?v=1783407942","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-1900-27-03-vibration-monitor-1900-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}