{"product_id":"bently-nevada-16925-33-interconnect-cable-3300-series","title":"Bently Nevada 16925-33 Interconnect Cable 3300 Series","description":"\u003cp\u003eConfigured for signal transmission in machine protection systems, the \u003cstrong\u003eBently Nevada 16925-33\u003c\/strong\u003e (\u003cstrong\u003e16925-33\u003c\/strong\u003e Interconnect Cable) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eCable Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eType: 3-conductor shielded instrumentation cable.\u003c\/li\u003e\n\u003cli\u003eConductor Gauge: 22 AWG (0.5 mm2).\u003c\/li\u003e\n\u003cli\u003eConnector Configuration: 3-socket plug at one end, terminal lugs at the opposite end.\u003c\/li\u003e\n\u003cli\u003eLength Range: Minimum 2.0 ft (0.6 m) to maximum 99 ft (30 m).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Electrical Data\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e16925-33\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.25 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e23 x 23 x 3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +105 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-50 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V AC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Count\u003c\/td\u003e\n\u003ctd\u003e3 (individually insulated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Integrity and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 16925-33 cable facilitates the precise transport of raw signals from eddy-current probes to monitoring instrumentation. Maintaining signal integrity is required for accurate gap voltage validation, typically targeted at -10 VDC for standard probe gaps. The cable's shielding geometry is engineered for cross-talk suppression and the reduction of electromagnetic interference in harsh turbine environments. Proper termination of the shield at the signal ground is required to maintain the stability of the rotor dynamics data stream and prevent ground loop injection into the monitoring circuit.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 unit 16925-33 Interconnect Cable\u003c\/li\u003e\n\u003cli\u003e1 set Installation technical documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDeployment Requirements\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure the cable routing avoids high-voltage power conduits to minimize inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003eVerify the shield is connected at the appropriate grounding terminal per the monitoring system manual.\u003c\/li\u003e\n\u003cli\u003eDo not exceed the minimum bend radius during installation to prevent deformation of the internal conductors.\u003c\/li\u003e\n\u003cli\u003eEnsure the 3-socket plug is fully seated and locked into the probe housing to prevent intermittent connections.\u003c\/li\u003e\n\u003cli\u003eApply cable ties at regular intervals to secure the run and prevent mechanical fatigue from vibration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum allowable length for this cable?\u003c\/p\u003e\n\u003cp\u003eThe cable supports a maximum length of 99 ft (30 m). Extending beyond this limit may result in signal attenuation and degradation of the eddy-current probe's frequency response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the shield continuous from end to end?\u003c\/p\u003e\n\u003cp\u003eYes, the shield is designed to be continuous throughout the cable length to provide uniform protection against EMI and RFI interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be used for high-temperature applications?\u003c\/p\u003e\n\u003cp\u003eThe cable is rated for operation up to +105 deg C. Ensure the application environment does not exceed this rating, as excessive heat will degrade the insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the terminal lugs be secured?\u003c\/p\u003e\n\u003cp\u003eThe terminal lugs should be fastened to the designated terminals with proper torque to ensure low-resistance electrical contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the cable require specific grounding?\u003c\/p\u003e\n\u003cp\u003eThe shield must be grounded at the monitor end to avoid ground loops. Refer to the specific 3300 series monitor installation guide for system grounding requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I field-repair the 3-socket plug?\u003c\/p\u003e\n\u003cp\u003eField repairs of the connector are not recommended. Damaged connectors should be replaced with factory-certified components to maintain signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable resistant to oil or chemical exposure?\u003c\/p\u003e\n\u003cp\u003eThe outer jacket is designed for industrial environments; however, verify the specific jacket material compatibility if exposed to aggressive synthetic lubricants or solvents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the gap voltage reading unstable?\u003c\/p\u003e\n\u003cp\u003eInstability may indicate a poor connection at the terminal lugs, shield grounding issues, or a damaged cable segment. Inspect the physical integrity of the cable and connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026793975981,"sku":"16925-33","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--4_13721fc5-96bb-455c-aa10-afb3ce8e2be8.jpg?v=1783404152","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-16925-33-interconnect-cable-3300-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}