{"product_id":"bently-nevada-135613-01-case-expansion-transducer-systems-24765-series","title":"Bently Nevada 135613-01 Case Expansion Transducer Systems 24765 Series","description":"\u003cp\u003eConfigured for case expansion displacement measurement in Bently Nevada transducer monitoring platforms, the \u003cstrong\u003eBently Nevada 135613-01\u003c\/strong\u003e (\u003cstrong\u003e24765\u003c\/strong\u003e Case Expansion Transducer Systems) provides direct physical\/electrical execution for converting mechanical thermal expansion movement into proportional DC voltage signals.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 135613-01 Case Expansion Transducer System is designed to measure relative expansion movement between machine casings and reference points. The system accepts DC power input and provides a voltage output proportional to measured displacement.\u003c\/p\u003e\n\u003cp\u003eThe transducer output range is configured as +1 to +6 VDC, with 135613-01 and 135613-11 models providing a sensitivity of 0.20 V\/mm (5.0 V\/in). The device is intended for mechanical condition monitoring applications requiring continuous case movement measurement.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e135613-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCase Expansion Transducer Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e24765 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 11.2 x 24.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-55 deg C to +125 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e30 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Power\u003c\/td\u003e\n\u003ctd\u003e+24 VDC, +13.5 to +26 VDC unregulated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e+1 to +6 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Noise\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e0.20 V\/mm (5.0 V\/in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e250 g for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Rating\u003c\/td\u003e\n\u003ctd\u003e10 g @ 0 to 2 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eRotor Dynamics and Expansion Measurement\u003c\/h3\u003e\n\u003cp\u003eThe 135613-01 transducer system provides mechanical displacement feedback for monitoring casing expansion behavior. The measurement circuit converts physical movement into an electrical voltage signal suitable for connection to monitoring equipment.\u003c\/p\u003e\n\u003cp\u003eFor accurate rotor dynamics analysis, the transducer installation position and mechanical reference alignment must remain stable. Proper calibration ensures that thermal expansion movement is represented correctly within the monitoring system.\u003c\/p\u003e\n\u003cp\u003eThe device operates with a direct voltage output format, eliminating additional signal conversion requirements between the transducer and compatible monitoring inputs.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 135613-01 Case Expansion Transducer System\u003c\/li\u003e\n\u003cli\u003e1 x Factory-configured transducer assembly\u003c\/li\u003e\n\u003cli\u003e1 x Product identification label\u003c\/li\u003e\n\u003cli\u003e1 x Technical documentation package when supplied\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Wiring Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the transducer on a stable mechanical reference surface.\u003c\/li\u003e\n\u003cli\u003eVerify the sensing direction matches the expected casing expansion movement.\u003c\/li\u003e\n\u003cli\u003eEnsure mounting hardware maintains consistent mechanical positioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUse shielded signal wiring when installed in electrically noisy environments.\u003c\/li\u003e\n\u003cli\u003eConnect signal cable shields according to site grounding practices.\u003c\/li\u003e\n\u003cli\u003eAvoid routing transducer wiring alongside high-current power conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommissioning Checks\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eVerify supply voltage polarity before energizing the device.\u003c\/li\u003e\n\u003cli\u003eConfirm output voltage changes correspond with actual mechanical displacement.\u003c\/li\u003e\n\u003cli\u003eCheck signal noise levels during normal operating conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat function does the 135613-01 provide?\u003c\/p\u003e\n\u003cp\u003eThe 135613-01 measures machine casing expansion movement and converts displacement into a proportional DC voltage output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input power does this transducer require?\u003c\/p\u003e\n\u003cp\u003eThe unit requires +24 VDC nominal input power and supports +13.5 to +26 VDC unregulated supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output signal is provided?\u003c\/p\u003e\n\u003cp\u003eThe transducer provides a +1 to +6 VDC output signal proportional to measured case expansion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the sensitivity of the 135613-01?\u003c\/p\u003e\n\u003cp\u003eThe 135613-01 provides a sensitivity of 0.20 V\/mm or 5.0 V\/in.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the output signal affected by electrical noise?\u003c\/p\u003e\n\u003cp\u003eThe specified output noise is less than 10 mV. Proper wiring practices help maintain signal quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this unit be used with Bently Nevada monitoring systems?\u003c\/p\u003e\n\u003cp\u003eThe device is designed as part of Bently Nevada transducer systems for mechanical displacement monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environmental limits apply to operation?\u003c\/p\u003e\n\u003cp\u003eThe operating temperature range is -25 deg C to +85 deg C, with specified shock and vibration ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the transducer require signal calibration?\u003c\/p\u003e\n\u003cp\u003eMechanical installation alignment and verification of output response are required during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026817994925,"sku":"135613-01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/135613-01.webp?v=1782790537","url":"https:\/\/www.maxwellplc.com\/ru\/products\/bently-nevada-135613-01-case-expansion-transducer-systems-24765-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}