{"product_id":"allen-bradley-smart-speed-controllers-150-f361nbdd-smart-motor-controller","title":"Allen-Bradley Smart Speed Controllers 150-F361NBDD SMART MOTOR CONTROLLER","description":"\u003cdiv class=\"ybc-p\"\u003eConfigured for reduced-voltage starting and DC-injection braking of 3-phase induction motors in Logix-driven MCC networks, the \u003cstrong\u003eAllen-Bradley 150-F361NBDD\u003c\/strong\u003e (\u003cstrong\u003e150-F\u003c\/strong\u003e SMART MOTOR CONTROLLER) provides direct thyristor phase-angle execution at 361 A.\u003c\/div\u003e\n\u003ch3\u003eCatalog Suffix Decoding\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component\"\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cstrong\u003e150-\u003c\/strong\u003e: Bulletin 150 SMC Flex solid-state reduced voltage controller\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cstrong\u003eF\u003c\/strong\u003e: Open-type enclosure, no integral disconnect\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cstrong\u003e361\u003c\/strong\u003e: 361 A rated operational current at 40 deg C (150-300 hp @ 460 VAC)\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Control voltage 100-240 VAC universal range\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Braking control enabled (DC injection \/ coast-to-stop logic)\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: Standard logic board, DeviceNet-ready header\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: Base firmware revision, no internal bypass contactor\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cdiv class=\"hyc-common-markdown__table-wrapper\"\u003e\n\u003cdiv class=\"hyc-common-markdown__table-actions-sticky\" id=\"tableActionsPanel\"\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\n\u003cdiv class=\"ybc-p\"\u003eParameter\u003c\/div\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cdiv class=\"ybc-p\"\u003eSpecification\u003c\/div\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eModel\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003e150-F361NBDD\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eBrand\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eAllen-Bradley\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eOrigin\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eUSA\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eWeight\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003e2.06 kg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eShipping Dimensions\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003e7.8 x 24 x 21.8 cm\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eOperating Temp\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003e0 to 40 deg C (1.5% current derate per deg C above 40 deg C)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003ePower Consumption\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003e\u0026lt; 22 W control section; thyristor conduction loss approx 1.4 V drop per anti-parallel pair\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eRated Operation Current Ie\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003e361 A at 40 deg C\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eRated Operating Voltage Ue\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003e200-480 VAC\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eInput Line Voltage\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003e200-460 VAC, 3-phase, 50\/60 Hz\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eControl Supply Voltage Us\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003e100-240 VAC, 50\/60 Hz\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eMotor Power Inline at 460 V\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003e150-300 hp\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eEnclosure\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eOpen\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eActuating Voltage Type\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eAC\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eProduct Family\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv class=\"ybc-p\"\u003eSMC Flex\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eEtherNet\/IP Producer-Consumer Mapping and Firmware Flash Lock\u003c\/h3\u003e\n\u003cdiv class=\"ybc-p\"\u003eThe 150-F361NBDD attaches to ControlLogix\/CompactLogix MCC structures via optional 150-COMM-EN or 150-COMM-DN daughterboards using CIP explicit messaging. Firmware flash compatibility is bound to SMC Flex v4.x images; loading 150-F625 or SMC-3 images corrupts the braking-parameter block and forces POST halt at 0x91. I\/O density scaling is fixed at 3 thyristor legs, 4 discrete status outputs, 2 analog ramp-monitor channels mirrored to Logix tags at 10 ms RPI. Backplane bus velocity licence does not apply—termination is panel-wire, not rack-plugged. DC-injection braking executes through two inverse-parallel thyristors after zero-speed detection, holding stator flux for 0.5-10 s adjustable decay; external bypass contactor is mandatory for continuous run to evacuate steady-state conduction loss.\u003c\/div\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component\"\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003e1 x 150-F361NBDD SMC Flex solid-state soft starter, open type\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003e1 x Wiring and parameter quick-reference label sheet\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Mounting and Conductor Rules\u003c\/h3\u003e\n\u003cul class=\"ybc-ul-component\"\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003eMount vertically on rigid steel panel with 100 mm top clearance, 50 mm bottom clearance for convection off thyristor heat sink.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003eTerminate line lugs with 4\/0 AWG Cu conductors (75 deg C rating), torque to 41 N·m.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003eSeparate 100-240 VAC control wiring from 460 VAC power bus by 200 mm or run in bonded metallic conduit.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003eBond PE terminal to panel ground stud with conductor sized per NEC 250.122 for 361 A service.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli class=\"ybc-li-component ybc-li-component_ul\"\u003e\n\u003cspan class=\"ybc-li-component__dot-wp\"\u003e\u003c\/span\u003e\n\u003cdiv class=\"ybc-p\"\u003eDo not exceed 40 deg C ambient without forced airflow of 0.35 m³\/s across rear fins.\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cdiv class=\"ybc-p\"\u003eQ: Can the 150-F361NBDD inject DC brake while line voltage is present?\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eA: No. DC injection initiates only after thyristor ramp completes and rotor speed falls below 15% synchronous. Activating brake logic during run holds thyristors blocked and trips on brake-overlap fault code 57.\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eQ: What control voltage range is permitted on the 100-240 VAC supply?\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eA: 90-264 VAC. Below 90 VAC the logic board resets; above 264 VAC the control transformer saturates and zero-cross detection drifts 0.8 ms per 10 V overvoltage.\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eQ: Does suffix B include an internal bypass contactor?\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eA: No. Last suffix D indicates no internal bypass. Continuous run requires an external 400 A AC-3 contactor driven by the run-ready relay output to avoid thyristor steady-state heating.\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eQ: How is braking decay time configured?\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eA: Via HIM or Logix tag BRAKE_DECAY_MS, range 500-10000 ms. Setting 0 disables DC injection and reverts to coast-to-stop. Out-of-range values clamp without fault.\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eQ: What is the thyristor forward drop at 361 A?\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eA: Approx 1.4 V per anti-parallel pair. Conduction loss = 1.4 V x 361 A x 3 = 1516 W to rear heat sink; panel ventilation must remove this at 40 deg C ambient.\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eQ: Can EtherNet\/IP and DeviceNet adapters be fitted simultaneously?\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eA: No. The logic daughterboard accepts one comms module. Swapping 150-COMM-DN for 150-COMM-EN requires power down and CIP parameter remap; concurrent fit bricks the HIM header.\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eQ: Minimum conductor temperature class for power terminals?\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eA: 75 deg C copper. Using 60 deg C conductors forces ampacity derating to 320 A, voids 361 A nameplate and causes overload trip at 90% FLC.\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eQ: How is firmware flashed on bench?\u003c\/div\u003e\n\u003cdiv class=\"ybc-p\"\u003eA: Via HIM port with 1756-USB and SMC Flex Flash tool. Image must match 150-F hardware ID 0x361. Mismatched flash halts boot at POST 0x91 and requires factory recovery dongle.\u003c\/div\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066387484845,"sku":"150-F361NBDD","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_2-3_6a1788ce-0a17-49d9-9ca3-4d6ce940eba0.jpg?v=1786074529","url":"https:\/\/www.maxwellplc.com\/ru\/products\/allen-bradley-smart-speed-controllers-150-f361nbdd-smart-motor-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}