{"product_id":"allen-bradley-powerflex-20f11fc104ja0nnnnn-ac-frequency-converter","title":"Allen-Bradley PowerFlex 20F11FC104JA0NNNNN AC frequency converter","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F11FC104JA0NNNNN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC frequency converter, operates as a dedicated hardware component for variable frequency motor speed and torque control within EtherNet\/IP deterministic networks.\u003c\/p\u003e\n\u003ch3\u003eBuilt-in Hardware Matrix Statement\u003c\/h3\u003e\n\u003cp\u003eThis asset constitutes a single integrated power conversion module specified under catalog identifier 20F11FC104JA0NNNNN. Based on engineering directives for this hardware category, the full alphanumeric model string represents a fixed factory assembly configuration containing definite parameters for filtration, mechanical cooling layout, frame dimensions, and internal braking electronics that must be operated as a non-divisible technical unit.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameter Table\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F11FC104JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21 x 59.5 x 17 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55 kW ND \/ 45 kW HD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 V AC, 3 Phase \/ 540 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e104 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFlange (NEMA\/UL Type 4X\/12 Back), Front Open\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrame Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrame 5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJumper Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDefault CM Jumper Installed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling Layout\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe internal processing architecture is designed to sustain continuous communication synchronization over EtherNet\/IP deterministic networks. The drive firmware supports active parameter mapping to control registers without degrading backplane bus communication velocity licenses. This ensures high-speed I\/O density scaling when exchanging torque, velocity, and diagnostic words with Logix-based automation controllers while adhering to established firmware flash compatibility matrices.\u003c\/p\u003e\n\u003ch3\u003eDelivery Components\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Allen-Bradley 20F11FC104JA0NNNNN AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Flange Mounting Gasket Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory Installed CM Jumper Reference Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting and Wiring Guidelines\u003c\/h3\u003e\n\u003ch3\u003eFlange Installation\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the Frame 5 chassis into the enclosure cutout, ensuring the NEMA\/UL Type 4X\/12 rear heatsink extends outside the cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTighten all flange mounting bolts evenly to compress the rear seal gasket and prevent ambient ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Termination\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnect incoming 400 V AC lines or matching 540 V DC bus terminals using distinct routed paths separated from low-voltage I\/O lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround the device directly from the internal protective ground lug to the enclosure common ground plane using low-impedance conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Engineering FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the safe temperature threshold for standard operation?\u003c\/p\u003e\n\u003cp\u003eThe drive functions within nominal parameters across an environmental ambient range of 0 to 50 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping option cards permitted while the system is powered?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swap operations are fully unsupported; all main input voltages and auxiliary control power must be isolated first.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the specific power capacities under different load conditions?\u003c\/p\u003e\n\u003cp\u003eThe unit outputs 104 Amps, corresponding to 55 kW Normal Duty or 45 kW HD operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat integrated braking components are built into this module?\u003c\/p\u003e\n\u003cp\u003eAn internal dynamic braking (DB) transistor is factory-installed, but external dynamic resistors must be added separately.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of human interface option is integrated into the front chassis?\u003c\/p\u003e\n\u003cp\u003eThis configuration features a HIM Blank cover plate, meaning no integrated Human Interface Module is present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical constraints apply to installation spaces and freight calculation?\u003c\/p\u003e\n\u003cp\u003eThe drive weighs 8 kg and requires a physical outline volume of 21 x 59.5 x 17 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input circuit design is utilized for the primary power stage?\u003c\/p\u003e\n\u003cp\u003eThe power circuitry features an AC \u0026amp; DC input line structure complete with precharge components and DC terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the default condition of the internal common mode capacitor configuration?\u003c\/p\u003e\n\u003cp\u003eThe drive is delivered with the internal CM jumper fully installed, matching grounded power system layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066461671597,"sku":"20F11FC104JA0NNNNN","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-24_ef338759-c482-4e2c-a12b-da8669652781.jpg?v=1782451486","url":"https:\/\/www.maxwellplc.com\/ru\/products\/allen-bradley-powerflex-20f11fc104ja0nnnnn-ac-frequency-converter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}