{"product_id":"allen-bradley-2711-t10g3-panelview-1000-standard-operator-terminal","title":"Allen-Bradley 2711-T10G3 PanelView 1000 Standard Operator Terminal","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711-T10G3\u003c\/strong\u003e is a PanelView 1000 Standard Operator Terminal manufactured by Rockwell Automation. It provides a grayscale touchscreen interface for machine-level monitoring and operator control, using DH-485 communication and an AC power supply. The terminal belongs to the legacy PanelView Standard 2711 product family.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T10G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eHMI Operator Terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePanelView 1000 Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePanelView Standard 2711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eActive Matrix TFT Grayscale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e10-inch class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Area\u003c\/td\u003e\n\u003ctd\u003e211 × 158 mm (8.3 × 6.2 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e640 × 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Colors\u003c\/td\u003e\n\u003ctd\u003e4 shades of gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen\u003c\/td\u003e\n\u003ctd\u003eResistive Touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Configuration\u003c\/td\u003e\n\u003ctd\u003e384 touch cells (24 columns × 16 rows)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eDH-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional Port\u003c\/td\u003e\n\u003ctd\u003eRS-232 Printer Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e55 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Flash Memory\u003c\/td\u003e\n\u003ctd\u003e1008 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 3.00 kg (6.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions (H × W × D)\u003c\/td\u003e\n\u003ctd\u003e282 × 370 × 112 mm (11.11 × 14.58 × 4.40 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 12\/13, Type 4X (indoor use only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP54 \/ IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming Software\u003c\/td\u003e\n\u003ctd\u003ePanelBuilder32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eDisplay and Touchscreen Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T10G3 uses an active-matrix TFT grayscale display with a cold-cathode fluorescent backlight. Its 640 × 480 resolution supports graphical operator screens, equipment status displays, and process information.\u003c\/p\u003e\n\u003cp\u003eThe touchscreen provides 384 individual touch cells arranged in 24 columns and 16 rows. Each interactive screen object occupies one or more touch cells.\u003c\/p\u003e\n\u003cp\u003eKey display characteristics:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFour shades of gray for visual differentiation.\u003c\/li\u003e\n\u003cli\u003e211 × 158 mm active display area.\u003c\/li\u003e\n\u003cli\u003e640 × 480 pixel resolution.\u003c\/li\u003e\n\u003cli\u003eResistive touchscreen operation.\u003c\/li\u003e\n\u003cli\u003e26 × 30 pixel touch cell size.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDH-485 Communication and Controller Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T10G3 uses the DH-485 communication protocol to exchange application data with compatible industrial controllers.\u003c\/p\u003e\n\u003cp\u003eThe terminal also provides an RS-232 printer interface for supported printing functions. Its DH-485 communication port supports network connections and application transfers using compatible communication cables and interface equipment.\u003c\/p\u003e\n\u003cp\u003eImportant communication characteristics:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDH-485 network communication.\u003c\/li\u003e\n\u003cli\u003eSelectable communication rates of 1,200, 2,400, 9,600, and 19,200 bps.\u003c\/li\u003e\n\u003cli\u003eMaximum documented DH-485 network distance of 1,219 m (4,000 ft).\u003c\/li\u003e\n\u003cli\u003eRS-232 printer communication interface.\u003c\/li\u003e\n\u003cli\u003eCompatible DH-485 programming connections using the appropriate interface cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhen connecting to SLC controllers or MicroLogix systems, verify the communication interface, cable configuration, and network topology before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and Electrical Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IC-rated AC configuration of the 2711-T10G3 operates from a wide-range AC input supply.\u003c\/p\u003e\n\u003cp\u003eElectrical requirements include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput voltage: 85-264 VAC.\u003c\/li\u003e\n\u003cli\u003eFrequency: 47-63 Hz.\u003c\/li\u003e\n\u003cli\u003eMaximum power consumption: 55 VA.\u003c\/li\u003e\n\u003cli\u003eProtective earth connection required.\u003c\/li\u003e\n\u003cli\u003eSeparate routing recommended for incoming power and communication cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe terminal should be connected to a dedicated branch circuit with suitable overcurrent protection. Rockwell Automation specifies a maximum 15 A fuse or circuit breaker for the input power source.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProgramming Software and Application Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T10G3 belongs to the legacy PanelView Standard platform and uses PanelBuilder32 for application development and configuration.\u003c\/p\u003e\n\u003cp\u003ePanelBuilder32 supports the creation of operator screens, alarms, data displays, and touchscreen controls. Existing applications can be transferred through compatible DH-485 communication interfaces.\u003c\/p\u003e\n\u003cp\u003eFor migration to a newer platform, Rockwell Automation documents importing PanelBuilder32 .pba application files into FactoryTalk View Studio Machine Edition.\u003c\/p\u003e\n\u003cp\u003eImportant migration considerations:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDH-485 communication must be changed to a supported communication method when moving to PanelView Plus 7.\u003c\/li\u003e\n\u003cli\u003eSome application objects and functions may require manual modification.\u003c\/li\u003e\n\u003cli\u003eConverted applications require functional testing before commissioning.\u003c\/li\u003e\n\u003cli\u003eExisting panel cutouts may require an adapter kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation and Panel Mounting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T10G3 is designed for installation in an industrial control panel or suitable enclosure.\u003c\/p\u003e\n\u003cp\u003eInstallation considerations:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ePrepare the panel cutout according to the manufacturer's installation drawing.\u003c\/li\u003e\n\u003cli\u003ePosition the terminal sealing gasket correctly before mounting.\u003c\/li\u003e\n\u003cli\u003eInsert the terminal into the prepared panel opening.\u003c\/li\u003e\n\u003cli\u003eSecure the terminal using the six supplied mounting clips.\u003c\/li\u003e\n\u003cli\u003eTighten the mounting clip screws to 1.13 Nm (10 lb-in).\u003c\/li\u003e\n\u003cli\u003eConnect AC power, protective earth, and the DH-485 communication cable.\u003c\/li\u003e\n\u003cli\u003eVerify the power supply and communication configuration before commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003e\u003cstrong\u003eImportant installation requirements:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDisconnect electrical power before installation or wiring.\u003c\/li\u003e\n\u003cli\u003eConnect the protective earth terminal to the appropriate grounding conductor.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the terminal.\u003c\/li\u003e\n\u003cli\u003eSeparate incoming power wiring from communication cables.\u003c\/li\u003e\n\u003cli\u003eRemove protective installation labels covering the top ventilation openings.\u003c\/li\u003e\n\u003cli\u003eUse an enclosure with the appropriate environmental rating.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe NEMA and IP protection ratings depend on installation in a suitably rated enclosure with correct gasket installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLifecycle Status and Replacement Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T10G3 is part of the legacy PanelView Standard product family. Rockwell Automation provides a migration path to the PanelView Plus 7 platform.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer's migration guide identifies the following primary replacement configuration:\u003c\/p\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eReplacement\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOriginal Model\u003c\/td\u003e\n\u003ctd\u003e2711-T10G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Terminal\u003c\/td\u003e\n\u003ctd\u003e2711P-T12W22D9P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter Kit\u003c\/td\u003e\n\u003ctd\u003e2711P-RAAT12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReplacement Display\u003c\/td\u003e\n\u003ctd\u003e12.1-inch color touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe replacement terminal does not provide direct DH-485 compatibility. Existing communication architecture and application files must be reviewed before migration.\u003c\/p\u003e\n\u003cp\u003eAn additional 24 VDC power supply is required when migrating from the original AC-powered terminal to the DC-powered replacement configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: What is the Allen-Bradley 2711-T10G3 used for?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides a touchscreen operator interface for monitoring machine conditions, displaying process information, and interacting with compatible PLC systems.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: What type of display does the 2711-T10G3 have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It features a 10-inch class grayscale TFT display with 640 × 480 pixel resolution and four shades of gray.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: Does the 2711-T10G3 support DH-485 communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It includes a DH-485 communication interface for connecting to compatible Allen-Bradley controllers and industrial networks.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: What power supply does this PanelView terminal require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 2711-T10G3 requires 85-264 VAC at 47-63 Hz, with a maximum power consumption of 55 VA.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: Which software is used to program the 2711-T10G3?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: PanelBuilder32 is the original application development software used to configure PanelView Standard terminals.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: What are the physical dimensions of the 2711-T10G3?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Its overall dimensions are approximately 282 × 370 × 112 mm (H × W × D), with a product weight of approximately 3.00 kg.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: Can the 2711-T10G3 application be migrated to PanelView Plus 7?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. PanelBuilder32 applications can be imported into FactoryTalk View Studio Machine Edition, although communication and application modifications may be required.\u003c\/p\u003e\n\u003cp\u003e- \u003cstrong\u003eQ: Is the 2711-T10G3 directly interchangeable with PanelView Plus 7?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. Migration requires communication changes, application conversion, and appropriate panel mounting and power supply arrangements.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":68367393161389,"sku":"2711-T10G3","price":1999.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2711-t10g3-1.jpg?v=1795082054","url":"https:\/\/www.maxwellplc.com\/ru\/products\/allen-bradley-2711-t10g3-panelview-1000-standard-operator-terminal","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}