{"product_id":"allen-bradley-20f11nd011ja0nnnnn-powerflex-753-ac-drive","title":"Allen-Bradley 20F11ND011JA0NNNNN PowerFlex 753 AC Drive","description":"\u003cp\u003eConfigured for precision motor induction management in 480 VAC 3-phase industrial power architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F11ND011JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct physical electrical execution for variable speed applications.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Architecture\u003c\/h3\u003e\n\u003cp\u003eThe model string 20F11ND011JA0NNNNN identifies a Frame 2 power chassis designed for a nominal output of 11 Amps. The drive architecture incorporates both AC and DC input terminals with precharge functionality, an integrated dynamic braking (DB) transistor for regenerative torque management, and a factory-fitted EMC filter with the common-mode (CM) jumper installed for line-side noise suppression.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F11ND011JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 cm x 40.5 cm x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefer to drive manual for thermal derating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 HP (ND) \/ 7.5 HP (HD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Type (IP20\/IP00)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Deterministic Network Attributes\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 753 platform utilizes high-speed internal bus communication to maintain deterministic control loops during motor operation. This hardware supports integration into EtherNet\/IP or Profinet deterministic networks, facilitating synchronized motion control and process data exchange. The system architecture permits modular I\/O density scaling, ensuring that firmware flash compatibility is maintained across varying control protocols during expansion or routine system maintenance.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 20F11ND011JA0NNNNN AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Embedded I\/O terminal assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: This unit is supplied without a Human Interface Module (HIM).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Install the Frame 2 chassis vertically within a NEMA-rated enclosure to ensure the forced-air cooling system remains within operational thermal limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Employ high-frequency shielded cabling for all motor-side wiring to effectively suppress radiated electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Establish a low-impedance bond between the drive chassis and the plant protective earth bus. Ensure the common-mode (CM) jumper remains installed to satisfy EMC filter performance criteria.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAirflow: Maintain the specified clearance above and below the drive to prevent heat recirculation and ensure optimal fan performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is a Human Interface Module (HIM) included?\u003c\/p\u003e\n\u003cp\u003eA: No, this unit is supplied as a \"Blank\" configuration, requiring an external HIM or configuration software for programming and status monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this model support DC input?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the drive is configured with both AC and DC input terminals, providing flexibility for specific power distribution architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the dynamic braking transistor integrated?\u003c\/p\u003e\n\u003cp\u003eA: Yes, this model includes an internal dynamic braking transistor to handle regenerative energy during motor deceleration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the ingress protection rating?\u003c\/p\u003e\n\u003cp\u003eA: As an Open Type (IP20\/IP00) device, the drive must be housed within a properly rated enclosure to prevent contamination from dust or moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the function of the CM jumper?\u003c\/p\u003e\n\u003cp\u003eA: The common-mode (CM) jumper is installed to provide the necessary reference for the internal EMC filter, minimizing conducted noise on the AC line side.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this drive in a corrosive gas environment?\u003c\/p\u003e\n\u003cp\u003eA: No, the drive features standard protection and requires an environmentally controlled enclosure if deployed in areas containing corrosive gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is firmware update capability supported?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the drive features flash-compatible firmware that can be updated via embedded communication ports to maintain network protocol alignment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What are the duty cycle ratings?\u003c\/p\u003e\n\u003cp\u003eA: The drive is rated for 7.5 HP in Normal Duty (ND) and 7.5 HP in Heavy Duty (HD) motor control applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066463965357,"sku":"20F11ND011JA0NNNNN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-33_71aea2bc-c46a-4439-a68c-4e92e6b5fb40.jpg?v=1782446569","url":"https:\/\/www.maxwellplc.com\/ru\/products\/allen-bradley-20f11nd011ja0nnnnn-powerflex-753-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}