{"product_id":"allen-bradley-2093-asp06-kinetix-2000-shunt-module","title":"Allen-Bradley 2093-ASP06 Kinetix 2000 Shunt Module","description":"\u003cp\u003eConfigured for regenerative energy dissipation in Kinetix 2000 drive architectures, the \u003cstrong\u003eAllen-Bradley 2093-ASP06\u003c\/strong\u003e (\u003cstrong\u003e2093-ASP06\u003c\/strong\u003e Shunt Module) provides direct electrical load management during motor deceleration cycles.\u003c\/p\u003e\n\u003ch3\u003eCatalog Nomenclature\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSeries: Kinetix 2000\u003c\/li\u003e\n\u003cli\u003eFunctional Class: Shunt Module\u003c\/li\u003e\n\u003cli\u003eBus Compatibility: 325 V DC\u003c\/li\u003e\n\u003cli\u003ePhysical Mounting: Power Rail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2093-ASP06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eKorea\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4 x 17.7 x 16.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Shunt\u003c\/td\u003e\n\u003ctd\u003e15 Ohm, 50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Input\u003c\/td\u003e\n\u003ctd\u003e0.05 A, 240-425 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMotion Control Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe module integrates with the drive system to monitor DC bus voltage levels during high-inertia stop sequences. By utilizing backplane bus communication velocity, the module executes precise energy dissipation, preventing DC bus over-voltage faults. Configuration is handled within the drive firmware environment, ensuring that the shunt engagement profiles align with the programmed deceleration rates of the connected servo axis.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e1 x 2093-ASP06 Shunt Module\u003c\/li\u003e\n\u003cli\u003e1 x Power rail connector interface\u003c\/li\u003e\n\u003cli\u003e1 x Installation instruction set\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMounting: Install the module on the Kinetix 2000 power rail; ensure the locking tabs are fully engaged to provide a secure mechanical and electrical connection.\u003c\/li\u003e\n\u003cli\u003eClearance: Maintain a minimum air gap of 50 mm above and below the shunt module to allow for thermal dissipation of the 50 W resistor load.\u003c\/li\u003e\n\u003cli\u003eWiring: Connect DC bus voltage leads according to the system wiring diagram; verify polarity to prevent short-circuit conditions.\u003c\/li\u003e\n\u003cli\u003eGrounding: Ensure the power rail system is properly bonded to the control cabinet's functional earth point.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of this module?\u003c\/p\u003e\n\u003cp\u003eThe shunt module dissipates excess energy generated by the motor during rapid deceleration, preventing the DC bus voltage from exceeding safe operating limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the internal shunt resistor replaceable?\u003c\/p\u003e\n\u003cp\u003eThe internal resistor is not field-serviceable; the entire module must be replaced if the internal component fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this module with other Kinetix series?\u003c\/p\u003e\n\u003cp\u003eThis module is specifically engineered for the Kinetix 2000 power rail architecture and is not compatible with other drive system series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the shunt resistor overheats?\u003c\/p\u003e\n\u003cp\u003eThe drive firmware monitors the thermal state of the shunt; if heat dissipation capacity is exceeded, the drive will trigger an over-temperature fault to protect hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the control input require an external 24 V DC supply?\u003c\/p\u003e\n\u003cp\u003eThe control input supports 240-425 V DC as specified; ensure the control voltage matches the drive bus configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the module electrically connected to the drive?\u003c\/p\u003e\n\u003cp\u003eThe module interfaces directly with the Kinetix 2000 power rail, which provides both the DC bus connection and the necessary control signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs airflow required for this module?\u003c\/p\u003e\n\u003cp\u003eThe module generates heat during shunt activation; natural convection is sufficient provided the installation clearance requirements are strictly followed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan multiple shunt modules be used in one system?\u003c\/p\u003e\n\u003cp\u003eExpansion is limited by the power rail capacity and the specific energy dissipation requirements of the multi-axis drive configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066460590253,"sku":"2093-ASP06","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen_bradley_2093-asp06.jpg?v=1783868269","url":"https:\/\/www.maxwellplc.com\/ru\/products\/allen-bradley-2093-asp06-kinetix-2000-shunt-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}