{"product_id":"allen-bradley-1734-ob8-point-i-o-digital-dc-sourcing-output-module","title":"Allen-Bradley 1734-OB8 POINT I\/O Digital DC Sourcing Output Module","description":"\u003cp\u003eConfigured for digital DC output signal execution in distributed industrial control networks, the \u003cstrong\u003eAllen-Bradley 1734-OB8\u003c\/strong\u003e (\u003cstrong\u003e1734-OB8\u003c\/strong\u003e POINT I\/O module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eNomenclature \u0026amp; Architectural Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProduct Base: 1734\u003c\/li\u003e\n\u003cli\u003eCatalog Number: OB8\u003c\/li\u003e\n\u003cli\u003eSeries Platform: POINT I\/O\u003c\/li\u003e\n\u003cli\u003eModule Variant: Digital DC Sourcing Output\u003c\/li\u003e\n\u003cli\u003eChannel Count: 8 Outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OB8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.04 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.1 cm x 5.6 cm x 7.6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.0 W (6.8 BTU\/hour)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10 V DC to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Network \u0026amp; Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eIntegrated across Profinet and EtherNet\/IP deterministic networks, this digital output module supports backplane bus communication velocity and I\/O density scaling. The onboard processing logic manages protocol conversion latencies and ensures firmware flash compatibility, enabling synchronized control execution across distributed network nodes without introducing packet jitter or communication drops.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 1734-OB8 Digital DC Sourcing Output Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Removable terminal base connector\u003c\/li\u003e\n\u003cli\u003e1 x Technical installation reference document\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnclosure Clearance: Maintain adequate vertical and horizontal spacing around the module housing to allow proper convective airflow and thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eDIN-Rail Mounting: Secure the unit firmly onto a standard 35 mm industrial DIN rail, verifying that the mechanical locking mechanism engages completely.\u003c\/li\u003e\n\u003cli\u003eWiring Termination: Connect field actuator lines securely into the terminal blocks, ensuring proper conductor strip length to prevent exposed copper.\u003c\/li\u003e\n\u003cli\u003eGrounding Compliance: Fasten the base assembly directly to a grounded metal panel or mounting plate to mitigate electromagnetic interference and ensure noise immunity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module drive inductive loads directly without external suppression diodes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Inductive loads connected to sourcing outputs require flyback diodes or surge suppression networks to safely absorb magnetic kickback energy and prevent premature contact wear or internal semiconductor breakdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How does the POINTBus current draw affect power supply sizing in an expanded chassis?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module draws 75 mA from the internal POINTBus, which must be factored alongside other connected cards to ensure the adapter power supply does not experience voltage sag or overload.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What troubleshooting steps are indicated when the module status indicator flashes red?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e A flashing red module status typically signals a recoverable or unrecoverable internal fault, configuration mismatch with the network scanner, or a faulted communication handshake over the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are output channels isolated from each other or grouped as a single common rail?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The 8 sourcing channels share common power distribution paths inside the block architecture, meaning individual channel-to-channel galvanic isolation is not present across the internal switching transistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What precautions must be observed during live-insertion and removal operations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e While the POINT I\/O backplane design permits removal under power in specific non-hazardous architectures, control outputs must be forced to a safe, de-energized state first to prevent unexpected machine actuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How do the yellow logic status indicators assist with diagnostic checks during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Each of the 8 yellow LEDs illuminates directly when the internal processor commands the corresponding output switch closed, allowing immediate visual verification of command logic versus field wiring state.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What impact does elevated ambient cabinet temperature have on the 3 A per module current rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e High internal enclosure temperatures reduce the thermal dissipation capacity of compact electronics, potentially requiring a de-rated maximum current load to prevent thermal trip or component degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is correct key switch positioning critical prior to mounting the module onto its base?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The mechanical key switch prevents accidental insertion of incompatible voltage types or module families into a wired terminal base, protecting internal circuitry from destructive over-voltage cross-wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066400362669,"sku":"1734-OB8","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/1734-OB8_13.jpg?v=1784728805","url":"https:\/\/www.maxwellplc.com\/ru\/products\/allen-bradley-1734-ob8-point-i-o-digital-dc-sourcing-output-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}