Allen-Bradley 1734-OB8 POINT I/O Digital DC Sourcing Output Module
-
Dimensions: 1.1 x 5.6 x 7.6 cm
-
Country of origin: USA
-
Payment: T/T, Western Union
-
Shipping port: Xiamen
Configured for digital DC output signal execution in distributed industrial control networks, the Allen-Bradley 1734-OB8 (1734-OB8 POINT I/O module) provides direct physical/electrical execution.
Nomenclature & Architectural Breakdown
- Product Base: 1734
- Catalog Number: OB8
- Series Platform: POINT I/O
- Module Variant: Digital DC Sourcing Output
- Channel Count: 8 Outputs
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 1734-OB8 |
| Brand | Allen-Bradley |
| Origin | USA |
| Weight | 0.04 kg |
| Shipping Dimensions | 1.1 cm x 5.6 cm x 7.6 cm |
| Operating Temp | Not specified |
| Power Consumption | 2.0 W (6.8 BTU/hour) |
| Output Voltage Range | 10 V DC to 28.8 V DC |
Industrial Network & Backplane Integration
Integrated across Profinet and EtherNet/IP deterministic networks, this digital output module supports backplane bus communication velocity and I/O density scaling. The onboard processing logic manages protocol conversion latencies and ensures firmware flash compatibility, enabling synchronized control execution across distributed network nodes without introducing packet jitter or communication drops.
Package Contents & Ordering Details
- 1 x 1734-OB8 Digital DC Sourcing Output Module unit
- 1 x Removable terminal base connector
- 1 x Technical installation reference document
Physical Installation Guidelines
- Enclosure Clearance: Maintain adequate vertical and horizontal spacing around the module housing to allow proper convective airflow and thermal dissipation.
- DIN-Rail Mounting: Secure the unit firmly onto a standard 35 mm industrial DIN rail, verifying that the mechanical locking mechanism engages completely.
- Wiring Termination: Connect field actuator lines securely into the terminal blocks, ensuring proper conductor strip length to prevent exposed copper.
- Grounding Compliance: Fasten the base assembly directly to a grounded metal panel or mounting plate to mitigate electromagnetic interference and ensure noise immunity.
Frequently Asked Questions
-
Q: Can this module drive inductive loads directly without external suppression diodes?
A: Inductive loads connected to sourcing outputs require flyback diodes or surge suppression networks to safely absorb magnetic kickback energy and prevent premature contact wear or internal semiconductor breakdown.
-
Q: How does the POINTBus current draw affect power supply sizing in an expanded chassis?
A: The module draws 75 mA from the internal POINTBus, which must be factored alongside other connected cards to ensure the adapter power supply does not experience voltage sag or overload.
-
Q: What troubleshooting steps are indicated when the module status indicator flashes red?
A: A flashing red module status typically signals a recoverable or unrecoverable internal fault, configuration mismatch with the network scanner, or a faulted communication handshake over the backplane.
-
Q: Are output channels isolated from each other or grouped as a single common rail?
A: The 8 sourcing channels share common power distribution paths inside the block architecture, meaning individual channel-to-channel galvanic isolation is not present across the internal switching transistors.
-
Q: What precautions must be observed during live-insertion and removal operations?
A: While the POINT I/O backplane design permits removal under power in specific non-hazardous architectures, control outputs must be forced to a safe, de-energized state first to prevent unexpected machine actuation.
-
Q: How do the yellow logic status indicators assist with diagnostic checks during operation?
A: Each of the 8 yellow LEDs illuminates directly when the internal processor commands the corresponding output switch closed, allowing immediate visual verification of command logic versus field wiring state.
-
Q: What impact does elevated ambient cabinet temperature have on the 3 A per module current rating?
A: High internal enclosure temperatures reduce the thermal dissipation capacity of compact electronics, potentially requiring a de-rated maximum current load to prevent thermal trip or component degradation.
-
Q: Why is correct key switch positioning critical prior to mounting the module onto its base?
A: The mechanical key switch prevents accidental insertion of incompatible voltage types or module families into a wired terminal base, protecting internal circuitry from destructive over-voltage cross-wiring.
Maxwell PLC is not an authorized distributor, reseller or representative of the products featured on this website. All product names, trademarks, brands and logos used on this site are the property of their respective owners. The depiction, description or sale of products featuring these names, trademarks, brands and logos is for identification purposes only and is not intended to indicate any affiliation with or authorization by any rights holder.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Shipping & Returns
Shipping
- Emergency Dispatch: Same-day shipping for in-stock orders placed before 2:00 PM (GMT+8).
- Premium Carriers: Reliable global delivery via DHL, FedEx, and UPS to 150+ countries.
- Flexible Options: We support shipping via your own carrier account (DHL/FedEx/UPS).
- Industrial Packaging: Professional ESD protection and reinforced shock-absorbent packaging.
Returns
- 30-Day Window: Request a return within 30 days of receipt for eligible items.
- Condition: Items must be in their original, factory-sealed condition with all tags.
- Hassle-Free Process: Contact sales@maxwellplc.com for a return label and instructions.
- Fast Refunds: Approved refunds are processed to your original payment method within 10 days.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Warranty
Warranty
- 12-Month Guarantee: A comprehensive one-year warranty covers all functional defects.
- Authenticity: Every part is guaranteed 100% original, brand-new, and genuine.
- Expert Support: Dedicated technical assistance to verify and resolve any hardware issues.
- Peace of Mind: Long-term reliability support for all your mission-critical automation parts.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.
Secure Payment
Secure Payment
- Flexible T/T: 100% T/T for stock items; 30% deposit / 70% balance for lead-time orders.
- Local Friendly: RMB transfers are accepted if you have a local agent in China.
- Best Price: Our Best Price Guarantee ensures you get the most competitive market rates.
- Data Safety: All transactions are processed through encrypted and secure banking channels.