{"product_id":"allen-bradley-150-f480nbdb-bulletin-150-smart-motor-controller","title":"Allen-Bradley 150-F480NBDB Bulletin 150 SMART Motor Controller","description":"\u003cp\u003eConfigured for solid-state motor starting and acceleration control in industrial drive systems, the \u003cstrong\u003eAllen-Bradley 150-F480NBDB\u003c\/strong\u003e (\u003cstrong\u003e150F480NBDB\u003c\/strong\u003e SMART MOTOR CONTROLLER) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eNomenclature Breakdown \u0026amp; Identifier Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBase model designation: 150-F480NBDB\u003c\/li\u003e\n\u003cli\u003eCurrent rating class: 480 A operational capacity\u003c\/li\u003e\n\u003cli\u003eInput voltage range: 200...480 V AC, 3-phase, 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eControl circuit voltage: 100...240 V AC supply\u003c\/li\u003e\n\u003cli\u003eIntegrated functionality: Pump control option enabled\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e150-F480NBDB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 24 x 21.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e400 hp rating at 460 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eController Type\u003c\/td\u003e\n\u003ctd\u003eBulletin 150, Solid State Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Line Voltage\u003c\/td\u003e\n\u003ctd\u003e200..480V AC, 3-Phase, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e100...240V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e480 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e460 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDrive Backplane Communication \u0026amp; Firmware Architecture\u003c\/h3\u003e\n\u003cp\u003eThe controller processes backplane bus communication velocity metrics to maintain precise synchronization across industrial drive nodes. Profinet and EtherNet\/IP deterministic networks integrate seamlessly with internal register maps via firmware flash compatibility protocols. Input and output density scaling parameters adjust dynamically to accommodate variable motor load profiles without sacrificing bus transmission integrity.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 150-F480NBDB Smart Motor Controller hardware assembly\u003c\/li\u003e\n\u003cli\u003e1 x Integrated control terminal block connector set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation \u0026amp; Electrical Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the open-style solid-state controller vertically inside a ventilated industrial enclosure, leaving adequate clearance above and below the chassis for thermal dissipation.\u003c\/li\u003e\n\u003cli\u003eConnect the 3-phase input lines directly to the main power terminals while verifying that incoming supply voltage matches the 200...480 V AC operational window.\u003c\/li\u003e\n\u003cli\u003eTerminate the separate 100...240 V AC control power source to the designated low-voltage terminals, ensuring physical separation from high-current motor cables.\u003c\/li\u003e\n\u003cli\u003eTorque all power and grounding fasteners to manufacturer-specified limits to prevent localized heating and maintain low-impedance earth continuity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eQ: Does this solid-state controller support live hot-swapping under active motor load conditions?\u003c\/li\u003e\n\u003cli\u003eA: No, hot-swapping is strictly prohibited. All primary line and control power must be completely locked out and verified dead before performing physical maintenance.\u003c\/li\u003e\n\u003cli\u003eQ: What is the primary function of the integrated pump control option on this model?\u003c\/li\u003e\n\u003cli\u003eA: The pump control algorithm dampens fluid pressure surges and eliminates hydraulic water hammer effects during motor start and stop sequences.\u003c\/li\u003e\n\u003cli\u003eQ: Can this unit operate on single-phase industrial power systems?\u003c\/li\u003e\n\u003cli\u003eA: No, the controller requires a balanced 3-phase 50\/60Hz input line voltage configuration ranging from 200 to 480 V AC.\u003c\/li\u003e\n\u003cli\u003eQ: What is the specified control voltage requirement for the internal logic circuitry?\u003c\/li\u003e\n\u003cli\u003eA: The control circuit requires an external supply voltage ranging between 100 and 240 V AC.\u003c\/li\u003e\n\u003cli\u003eQ: How are internal semiconductor firing states cooled during extended motor acceleration?\u003c\/li\u003e\n\u003cli\u003eA: Thermal energy is dissipated through natural convection across the integrated heatsink profile, requiring adequate ambient airflow inside the enclosure.\u003c\/li\u003e\n\u003cli\u003eQ: What maximum motor horsepower does this specific controller configuration support?\u003c\/li\u003e\n\u003cli\u003eA: The unit supports a maximum power rating of 400 hp when operating at a nominal line voltage of 460 V AC.\u003c\/li\u003e\n\u003cli\u003eQ: Are firmware updates compatible with standard Allen-Bradley programming tools?\u003c\/li\u003e\n\u003cli\u003eA: Yes, firmware flash compatibility allows version updates using authorized configuration software connected through the internal communication port.\u003c\/li\u003e\n\u003cli\u003eQ: What physical environmental limits apply to the open-type enclosure design?\u003c\/li\u003e\n\u003cli\u003eA: The controller must be housed within a protective cabinet rated for the specific industrial environment, maintaining an ambient temperature range of 0 deg C to +50 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066389188781,"sku":"150-F480NBDB","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_2-3_4ef29da9-796f-4574-89f2-f3c8324aeadf.jpg?v=1786074557","url":"https:\/\/www.maxwellplc.com\/ru\/products\/allen-bradley-150-f480nbdb-bulletin-150-smart-motor-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}