{"product_id":"allen-bradley-150-f43nbr-smc-flex-series-smart-motor-controller","title":"Allen-Bradley 150-F43NBR SMC Flex Series Smart Motor Controller","description":"\u003cp\u003eConfigured for reduced-voltage solid-state motor starting in 3-phase AC industrial power circuits, the \u003cstrong\u003eAllen-Bradley 150-F43NBR\u003c\/strong\u003e (\u003cstrong\u003e150-F43NBR\u003c\/strong\u003e Smart Motor Controller) provides direct physical\/electrical execution for controlled torque acceleration, current limiting, and soft stopping profiles.\u003c\/p\u003e\n\u003ch3\u003eHardware Designation Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e150-F\u003c\/strong\u003e: Bulletin 150 SMC Flex solid-state motor controller chassis structure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e43\u003c\/strong\u003e: 43 A continuous current rating supporting 7.5 to 30.0 hp motor loads at 460 VAC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN\u003c\/strong\u003e: Open enclosure frame designed for panel mounting inside industrial control cabinets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: 200...480 VAC 3-phase line input operating threshold at 50\/60 Hz.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR\u003c\/strong\u003e: Low-voltage 24 VAC\/DC control supply circuit interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e150-F43NBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e7.8 x 24.0 x 21.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard Internal Control Dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current\u003c\/td\u003e\n\u003ctd\u003e43 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Input Voltage\u003c\/td\u003e\n\u003ctd\u003e200...480 VAC (3-Phase, 50\/60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Rating\u003c\/td\u003e\n\u003ctd\u003e30 hp (7.5 to 30.0 hp at 460 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VAC\/DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Style\u003c\/td\u003e\n\u003ctd\u003eOpen Enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Profile\u003c\/td\u003e\n\u003ctd\u003eStandard Soft Start \u0026amp; Current Limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Communication \u0026amp; Controller Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe solid-state controller routes diagnostic metrics, operational feedback, and current telemetry over EtherNet\/IP deterministic networks via optional communication adapters. Embedded control microcode maintains strict firmware flash compatibility across control nodes, preventing handshake latency and backplane timing skew during real-time automated PLC sweep updates.\u003c\/p\u003e\n\u003ch3\u003eSupplied Hardware Package\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 150-F43NBR Smart Motor Controller\u003c\/li\u003e\n\u003cli\u003e1 x Installation Instruction Leaflet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eControl Cabinet Setup \u0026amp; Electrical Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMechanical Chassis Mounting\n\u003cul\u003e\n\u003cli\u003eMount the open unit vertically on a flat, grounded panel surface to ensure adequate heat dissipation via natural vertical air convection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh-Voltage Power Wiring\n\u003cul\u003e\n\u003cli\u003eConnect 3-phase power input leads to terminals L1, L2, L3 and motor output cables to T1, T2, T3 according to marked terminal torque specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eControl Circuit Wiring\n\u003cul\u003e\n\u003cli\u003eTerminate the 24 VAC\/DC control supply using dedicated shielded cables isolated from high-power distribution lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eProtective Earth Grounding\n\u003cul\u003e\n\u003cli\u003eBond a heavy-gauge copper grounding wire directly from the main panel ground bus to the chassis protective earth terminal before applying power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Engineering FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat continuous current capacity does the 150-F43NBR provide?\u003c\/p\u003e\n\u003cp\u003eThe controller delivers a continuous output current rating of 43 A for 3-phase AC induction motors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat control supply voltage is required for internal logic activation?\u003c\/p\u003e\n\u003cp\u003eThe unit operates using a low-voltage 24 VAC\/DC control supply connected to its designated control terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping permitted on power terminals during operational states?\u003c\/p\u003e\n\u003cp\u003eNo, line power and control power sources must be completely disconnected before modifying terminal connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat motor horsepower range is supported at 460 VAC line voltage?\u003c\/p\u003e\n\u003cp\u003eThe controller manages 3-phase induction motors rated between 7.5 hp and 30.0 hp at 460 VAC line input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this open-enclosure model require an external protective panel?\u003c\/p\u003e\n\u003cp\u003eYes, as an open enclosure unit, it must be installed within a NEMA or IP rated cabinet to maintain environmental protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit maintain parameter consistency over fieldbus networks?\u003c\/p\u003e\n\u003cp\u003eOptional communication modules interface with internal registers while maintaining firmware flash compatibility across nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat input line voltage parameters apply to the main power circuit?\u003c\/p\u003e\n\u003cp\u003eThe main power circuit accepts 3-phase AC operating line voltages from 200 VAC to 480 VAC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat installation orientation is required for correct thermal management?\u003c\/p\u003e\n\u003cp\u003eThe chassis must be mounted vertically on an unpainted metal backpanel to allow convection cooling across internal heat sinks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066388271277,"sku":"150-F43NBR","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/150-F6_4-1_307920e2-85fa-41dd-9c7b-503639461c4f.jpg?v=1786074554","url":"https:\/\/www.maxwellplc.com\/ru\/products\/allen-bradley-150-f43nbr-smc-flex-series-smart-motor-controller","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}