{"product_id":"acs-ap-s-3abd0000064884-abb-acs580-series-control-panel","title":"ACS-AP-S 3ABD0000064884 ABB ACS580 Series Control Panel","description":"\u003cp\u003eThe \u003cstrong\u003eABB ACS-AP-S 3ABD0000064884\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eACS-AP-S\u003c\/strong\u003e assistant control panel, operates as a dedicated hardware component for human-machine parameter configuration and drive state visualization within ACS580 control networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Variant \u0026amp; Interface Overview\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer Ordering Code\u003c\/strong\u003e: 3ABD0000064884\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Panel Variant\u003c\/strong\u003e: ACS-AP-S\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDisplay Interface\u003c\/strong\u003e: Backlit LCD matrix (128 x 64 pixels resolution)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperator Keypad\u003c\/strong\u003e: Sealed dustproof membrane keyboard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFront Ingress Rating\u003c\/strong\u003e: IP54 compliant front enclosure protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMean Time Between Failures\u003c\/strong\u003e: \u0026gt; 150000 hours\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Data\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eACS-AP-S (3ABD0000064884)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e2.8 cm x 7.3 cm x 2.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (+\/-10 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Ground Isolation\u003c\/td\u003e\n\u003ctd\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional Interface Input\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V analog input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Vibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1G (5 to 100 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd\u003e5 to 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eReal-Time Bus Transmission \u0026amp; Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eThe control panel features firmware flash compatibility to support dynamic language loading and firmware parameter uploads\/downloads across host VFD controllers. High-speed backplane bus communication velocity licences ensure real-time telemetry rendering and fault log polling over Profinet \/ EtherNet\/IP networks without introducing latency during motor parameter adjustments.\u003c\/p\u003e\n\u003ch3\u003eLogistics Scope of Supply\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB ACS-AP-S assistant control panel (3ABD0000064884)\u003c\/li\u003e\n\u003cli\u003e1 x Panel mounting gasket and locking clip kit\u003c\/li\u003e\n\u003cli\u003e1 x User guide technical manual sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Door Mounting \u0026amp; Field Wiring Directives\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoor Panel Cutout Preparation\u003c\/strong\u003e: Install the panel into a smooth enclosure cutout using the integrated sealing gasket to preserve the IP54 front ingress rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Plug Protocol\u003c\/strong\u003e: Align the panel rear interface connector precisely with the drive bezel slot before pushing into place to prevent pin deflection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shield Anchorage\u003c\/strong\u003e: When utilizing remote door mounting kits, employ fully shielded twisted-pair patch cables with grounded metallic connector shells.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary Input Line Routing\u003c\/strong\u003e: Route optional 0 to 10 V analog feedback lines separately from high-voltage AC power wiring to avoid noise pickup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage is required to power the ACS-AP-S control panel?\u003c\/p\u003e\n\u003cp\u003eThe panel operates on an auxiliary 24 VDC (+\/-10 %) supply delivered directly through the drive RJ-45 connection interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum power dissipation is generated by the unit during full backlighting?\u003c\/p\u003e\n\u003cp\u003eThe unit draws a maximum electrical power consumption of 5 W under full LCD backlight and processing load conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the control panel be inserted or detached while the host drive is energized?\u003c\/p\u003e\n\u003cp\u003eYes, the panel interface supports hot-swapping into the drive bezel slot without interrupting motor control execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat display resolution and visual interface are incorporated on the panel?\u003c\/p\u003e\n\u003cp\u003eThe display features a backlit LCD matrix delivering 128 x 64 pixels resolution with multi-language graphic menu navigation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat electrical isolation is maintained between interface signals and frame ground?\u003c\/p\u003e\n\u003cp\u003eThe internal electronics incorporate 500 V channel-to-ground isolation to guard against ground loop differential noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environmental protection rating applies to the panel front face?\u003c\/p\u003e\n\u003cp\u003eThe front membrane keypad and display window conform to IP54 dust and splash protection standards when seated properly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat vibration resistance tolerance does the hardware withstand?\u003c\/p\u003e\n\u003cp\u003eThe internal circuit board and enclosure assembly withstand continuous mechanical vibration levels up to 1G across 5 to 100 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are firmware updates transferred to the control panel?\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility allows firmware packages and parameter sets to be flashed directly via the drive backplane connection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021091590317,"sku":"3ABD0000064884","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/acs-ap-s3abd0000064884_3.jpg?v=1791954133","url":"https:\/\/www.maxwellplc.com\/ru\/products\/acs-ap-s-3abd0000064884-abb-acs580-series-control-panel","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}