{"product_id":"abb-tx560-3bse005881r1-terminator-box-s800-i-o-series","title":"ABB TX560 3BSE005881R1 Terminator Box S800 I\/O Series","description":"\u003cp\u003eConfigured for communication line termination and bus signal impedance matching in S800 I\/O systems, the \u003cstrong\u003eABB TX560 3BSE005881R1\u003c\/strong\u003e (\u003cstrong\u003eTX560 3BSE005881R1\u003c\/strong\u003e Terminator Box) provides direct physical\/electrical execution. This passive hardware unit terminates the physical end of the ModuleBus extension segment, preventing high-frequency electrical signal reflections and maintaining deterministic data transmission across distributed controller communication lines.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Classification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003ctd\u003eSystem Manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eTX560 3BSE005881R1\u003c\/td\u003e\n\u003ctd\u003eModuleBus Bus Terminator Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eTX560\u003c\/td\u003e\n\u003ctd\u003eProduct Family Identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct ID\u003c\/td\u003e\n\u003ctd\u003e3BSE005881R1\u003c\/td\u003e\n\u003ctd\u003eOfficial Part Catalog Number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eS800 I\/O\u003c\/td\u003e\n\u003ctd\u003eDistributed I\/O System Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003ctd\u003eInternational Harmonized System Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTX560 3BSE005881R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.3 cm x 10.7 cm x 13.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e3.3 cm x 10.7 cm x 13.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (0 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eBus Line Impedance Termination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDirect ModuleBus \/ DIN Rail Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Backplane Bus Velocity and Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe TX560 3BSE005881R1 provides precise transmission line impedance matching at the physical boundary of the ModuleBus extension network. By absorbing traveling voltage waves at the line end, the terminator box eliminates signal reflections and standing waves that degrade high-velocity backplane data packets. This termination maintains low noise margins and signal integrity across high-density I\/O clusters linked to AC 800M or S800 Fieldbus Communication Interfaces (FCI).\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x ABB TX560 3BSE005881R1 Terminator Box\u003c\/li\u003e\n\u003cli\u003e1x Installation Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Connect the TX560 directly to the designated ModuleBus extension interface or terminal mounting unit at the physical end of the S800 I\/O cluster.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Termination Rule:\u003c\/strong\u003e Ensure exactly one termination box is installed at the final physical node of the optical or electrical ModuleBus line segment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Strain Relief:\u003c\/strong\u003e Secure incoming ModuleBus extension cables with appropriate mounting clips to prevent mechanical strain on internal connector pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding:\u003c\/strong\u003e Connect cable shield braids to the local frame ground (FG) earth bar via 360-deg grounding clamps. Maintain earth path resistance below 100 ohms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the main function of the TX560 3BSE005881R1 Terminator Box?\u003c\/p\u003e\n\u003cp\u003eThe module provides impedance matching at the end of an S800 ModuleBus line to eliminate signal reflections and preserve communications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhere should the TX560 terminator box be placed in an S800 I\/O cluster?\u003c\/p\u003e\n\u003cp\u003eThe TX560 must be installed at the last physical station or position on the ModuleBus extension segment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the TX560 3BSE005881R1 require an active 24 VDC power supply?\u003c\/p\u003e\n\u003cp\u003eNo, the TX560 is a passive hardware component and consumes 0 W of electrical power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the ModuleBus segment is operated without the TX560 terminator?\u003c\/p\u003e\n\u003cp\u003eUnterminated bus lines cause voltage wave reflections, leading to communication timing errors, frame corruption, and I\/O bus faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operating temperature limits are specified for the TX560?\u003c\/p\u003e\n\u003cp\u003eThe terminator box is rated for operating field environments ranging from -25 deg C to +70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the TX560 be installed or removed under live system power?\u003c\/p\u003e\n\u003cp\u003eWhile passive, removing the terminator during operation breaks bus impedance, causing communication drops across active I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable shielding procedures apply to the ModuleBus extension lines?\u003c\/p\u003e\n\u003cp\u003eModuleBus cables require continuous braid shielding attached to the panel earth bar with a 360-deg clamp under 100 ohms resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the TX560 compatible with all ABB S800 I\/O ModuleBus extensions?\u003c\/p\u003e\n\u003cp\u003eYes, the TX560 is designed specifically for terminating standard S800 I\/O electrical ModuleBus extension line architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021048041645,"sku":"TX560 3BSE005881R1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_tx560_3bse005881r1.jpg?v=1787400565","url":"https:\/\/www.maxwellplc.com\/ru\/products\/abb-tx560-3bse005881r1-terminator-box-s800-i-o-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}