{"product_id":"abb-sptkm11-soe-clock-module-bailey-infi-90-series","title":"ABB SPTKM11 SOE Clock Module Bailey Infi 90 Series","description":"\u003cp\u003eThe \u003cstrong\u003eABB SPTKM11\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSPTKM11\u003c\/strong\u003e SOE Clock Module, operates as a dedicated hardware component for Sequence of Events (SOE) time synchronization and master clock signal distribution within ABB Bailey Infi 90 distributed control system architectures. Configured for high-accuracy temporal synchronization, this module decodes external time signals to maintain sub-millisecond event timestamping across distributed plant I\/O nodes and system controllers.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Classification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003ctd\u003eSystem Manufacturer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eSPTKM11\u003c\/td\u003e\n\u003ctd\u003eSequence of Events (SOE) Clock Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eBailey Infi 90\u003c\/td\u003e\n\u003ctd\u003eDistributed Control System Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003ctd\u003eInternational Harmonized System Code\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSPTKM11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e18.0 cm x 17.6 cm x 2.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.0 cm x 19.0 cm x 4.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-25 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Sync Input\u003c\/td\u003e\n\u003ctd\u003eIRIG-B (modulated \/ DC level)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Voltage\u003c\/td\u003e\n\u003ctd\u003eTTL \/ RS-422 compatible (0 to 5 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003eDIN rail or panel (ABB S800 I\/O base)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Backplane Bus Velocity and Synchronization Determinism\u003c\/h3\u003e\n\u003cp\u003eThe SPTKM11 delivers high-velocity backplane time signal processing by interfacing IRIG-B reference signals directly to the DCS communication bus. Operating with 1500 VAC galvanic isolation, the module eliminates ground loops while parsing modulated or DC-level IRIG-B timecodes into 1 ms resolution timestamps. Internal high-speed logic synchronizes process controllers and event recorder modules across the backplane bus, preventing time drift and guaranteeing deterministic Sequence of Events resolution during rapid fault cascades across the control network.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x ABB SPTKM11 SOE Clock Module\u003c\/li\u003e\n\u003cli\u003e1x Factory Test Certificate\u003c\/li\u003e\n\u003cli\u003e1x Installation Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Configuration:\u003c\/strong\u003e Mount the module on a standard 35 mm DIN rail or attach directly to a compatible ABB S800 I\/O baseplate within an IP20 minimum enclosure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Connections:\u003c\/strong\u003e Connect a regulated 24 VDC external power supply to the module power terminals. Verify power consumption remains within the 8 W rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Shielding:\u003c\/strong\u003e Use shielded twisted-pair cabling for TTL\/RS-422 and IRIG-B time synchronization inputs. Ground the outer braid shield 360-deg to the frame ground earth bar.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Requirements:\u003c\/strong\u003e Ensure the chassis frame ground (FG) terminal is connected to an earth ground with a low-impedance path resisting less than 100 ohms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary function of the SPTKM11 module?\u003c\/p\u003e\n\u003cp\u003eThe module provides high-accuracy temporal synchronization by decoding IRIG-B time inputs for Sequence of Events timestamping across DCS nodes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat time synchronization input formats does the module support?\u003c\/p\u003e\n\u003cp\u003eThe SPTKM11 accepts both modulated and DC-level IRIG-B time synchronization inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the time timestamping accuracy provided by the SPTKM11?\u003c\/p\u003e\n\u003cp\u003eThe module provides a time resolution of 1 ms with a absolute accuracy rating of +\/-1 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal voltage levels are compatible with the time sync inputs?\u003c\/p\u003e\n\u003cp\u003eThe signal inputs accept TTL and RS-422 compatible voltage levels operating within 0 to 5 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat isolation voltage level is provided between system circuits?\u003c\/p\u003e\n\u003cp\u003eThe internal circuitry features 1500 VAC galvanic isolation to protect system logic from field-side transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the SPTKM11 module be mounted on a standard DIN rail?\u003c\/p\u003e\n\u003cp\u003eYes, the module is designed for mounting on standard 35 mm DIN rails or direct panel mounting on an ABB S800 I\/O baseplate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping permitted for the SPTKM11 on a live backplane?\u003c\/p\u003e\n\u003cp\u003ePower to the 24 VDC supply line should be isolated before inserting or removing the module to prevent electrical arcing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat shielding method is recommended for IRIG-B signal cables?\u003c\/p\u003e\n\u003cp\u003eUse shielded twisted-pair wiring with a 360-deg braid shield grounding connection to an earth ground under 100 ohms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021064655021,"sku":"SPTKM11","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_sptkm11.jpg?v=1787399802","url":"https:\/\/www.maxwellplc.com\/ru\/products\/abb-sptkm11-soe-clock-module-bailey-infi-90-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}