{"product_id":"abb-s200-ie8-s200-i-o-analog-input-module","title":"ABB S200-IE8 S200 I\/O Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB S200-IE8\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e200-IE8\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-channel analog signal conversion and voltage monitoring within S200 I\/O platforms.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown and Variant Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrimary Product Model: S200-IE8\u003c\/li\u003e\n\u003cli\u003eAlternative Catalog Part: 200-IE8\u003c\/li\u003e\n\u003cli\u003eLegacy Identifier: 490176097 S200IE8\u003c\/li\u003e\n\u003cli\u003eHardware Architecture: 8-Channel Analog Input Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS200-IE8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e9.3 x 5.4 x 4.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDerived from 24 VDC bus rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore Function\u003c\/td\u003e\n\u003ctd\u003e8-channel analog current and voltage signal processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Network Integration\u003c\/h3\u003e\n\u003cp\u003eConfigured for high-density analog acquisition in industrial control systems, the ABB S200-IE8 manages deterministic network communication across backplane architecture. The integrated backplane bus communication velocity synchronizes real-time data exchange with central processing units, while firmware flash compatibility permits field updates and parameter scaling. I\/O density scaling optimizes cabinet footprint by terminating eight independent loops through compact terminal connections.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x S200-IE8 Analog Input Module unit\u003c\/li\u003e\n\u003cli\u003e1 x Terminal block connector interface\u003c\/li\u003e\n\u003cli\u003e1 x ESD protective storage enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDIN Rail Mounting: Secure the module firmly onto a grounded 35 mm metallic DIN rail, ensuring positive mechanical locking prior to module energization.\u003c\/li\u003e\n\u003cli\u003eShield Grounding: Terminate all analog signal cable shields to the designated ground bar adjacent to the I\/O base to prevent electromagnetic noise induction.\u003c\/li\u003e\n\u003cli\u003ePower Isolation: Disconnect external 24 VDC supply loops before inserting or extracting the module from the active backplane rack.\u003c\/li\u003e\n\u003cli\u003eWiring Segregation: Route low-voltage analog input conductors through dedicated wire ducts separate from high-voltage AC or DC power cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the S200-IE8 support live hot-swap replacement during active system operation?\u003c\/p\u003e\n\u003cp\u003eNo. Insertion or removal of the module while system power is active can cause bus communication errors or internal logic component damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the nominal operating voltage required for module logic circuitry?\u003c\/p\u003e\n\u003cp\u003eThe module operates on a regulated 24 VDC supply delivered directly through the system backplane interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many independent input channels are available on this hardware variant?\u003c\/p\u003e\n\u003cp\u003eThe unit provides eight discrete analog input channels capable of processing standard industrial signal ranges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary cause of analog reading fluctuations on field channels?\u003c\/p\u003e\n\u003cp\u003eInadequate cable shielding, improper ground reference potential, or electromagnetic interference from adjacent high-power lines typically cause signal instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre there any physical configuration jumpers located on the module PCB?\u003c\/p\u003e\n\u003cp\u003eNo. Input channel configuration and scaling parameters are managed entirely through software settings within the programming environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat environmental conditions must be maintained inside the control cabinet?\u003c\/p\u003e\n\u003cp\u003eThe enclosure must remain free of corrosive gases, conductive dust, and maintain ambient temperatures within the specified thermal limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are field sensors connected to the module input terminals?\u003c\/p\u003e\n\u003cp\u003eField wiring is terminated via pluggable terminal blocks that interface directly with the front face of the hardware module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat diagnostic features are integrated into the module hardware?\u003c\/p\u003e\n\u003cp\u003eOn-board status light-emitting diodes provide visual feedback regarding module operational health, power status, and channel error states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021158863021,"sku":"S200-IE8","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/S200-IE8_1.jpg?v=1784536388","url":"https:\/\/www.maxwellplc.com\/ru\/products\/abb-s200-ie8-s200-i-o-analog-input-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}