{"product_id":"abb-nkas01-9-bailey-infi-90-analog-module-termination-cable","title":"ABB NKAS01-9 Bailey Infi 90 Analog Module Termination Cable","description":"\u003cp\u003eConfigured for analog signal routing and module termination in Bailey Infi 90 platforms, the \u003cstrong\u003eABB NKAS01-9\u003c\/strong\u003e (\u003cstrong\u003eNKAS01-9\u003c\/strong\u003e Analog Module Termination Cable) provides direct physical\/electrical execution. It interconnects front-end analog I\/O units to MMU-TU termination assemblies over a 9 ft (2.74 m) path. The cable incorporates 20-22 AWG multi-conductor wiring rated for 300 V AC and 2 A per conductor across operational thermal environments spanning -20 deg C to +80 deg C.\u003c\/p\u003e\n\u003ch3\u003eCable Identification \u0026amp; Part Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNKAS01-9\u003c\/strong\u003e: Complete assembly part number specifying a 9 ft total cable length.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNKAS01 Base Designation\u003c\/strong\u003e: Model family for Infi 90 \/ Network 90 analog termination cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMMU-TU Interface\u003c\/strong\u003e: Dedicated connector termination profile mating module slots to terminal units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNKAS01-9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 cm x 11.0 cm x 11.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.5 cm x 11.0 cm x 11.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.74 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e9 ft (2.74 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Gauge\u003c\/td\u003e\n\u003ctd\u003e20-22 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e2 A per conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic IO Signal Integrity \u0026amp; Backplane Integration\u003c\/h3\u003e\n\u003cp\u003eThe NKAS01-9 assembly enforces precise signal fidelity across expanded Infi 90 chassis structures, preventing high-frequency noise insertion into low-level analog channels. Optimized conductor spacing maintains high backplane bus communication velocity and protects differential analog inputs from adjacent field interference. Cable shielding and low-impedance paths support high I\/O density scaling while maintaining full firmware flash compatibility and signal alignment across host controller racks.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x ABB NKAS01-9 Analog Module Termination Cable (9 ft)\u003c\/li\u003e\n\u003cli\u003e1x Protective Anti-Static Packaging Sleeve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Routing Limits\u003c\/strong\u003e: Route the termination cable through dedicated low-voltage wiring troughs separate from high-voltage AC power lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBend Radius Compliance\u003c\/strong\u003e: Maintain a minimum static bend radius of 6x the overall cable diameter during cabinet installation to prevent conductor fatigue.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Latching\u003c\/strong\u003e: Engage both strain-relief retention screws fully at the MMU-TU interface to prevent accidental mechanical disconnects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShield Grounding\u003c\/strong\u003e: Ensure the integrated overall shield ground braid connects directly to the cabinet frame ground bar to optimize noise suppression.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum current capacity per conductor on the NKAS01-9?\u003c\/p\u003e\n\u003cp\u003eEach conductor inside the assembly supports a maximum continuous current rating of 2 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat system interface does the NKAS01-9 termination cable connect?\u003c\/p\u003e\n\u003cp\u003eIt connects Bailey Infi 90 analog modules directly to MMU-TU field termination units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable rated for operation in high-temperature environments?\u003c\/p\u003e\n\u003cp\u003eYes, the assembly operates continuously within an ambient temperature range of -20 deg C to +80 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat conductor wire gauge is utilized inside the cable assembly?\u003c\/p\u003e\n\u003cp\u003eThe cable uses multi-strand copper conductors sized between 20 AWG and 22 AWG.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat dielectric voltage rating applies to the NKAS01-9 assembly?\u003c\/p\u003e\n\u003cp\u003eThe internal conductor insulation carries an official electrical insulation rating of 300 V AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the overall cable shield be grounded during field setup?\u003c\/p\u003e\n\u003cp\u003eConnect the shield drain wire to the dedicated chassis ground lug at the termination unit end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the NKAS01-9 cable be hot-plugged during active process execution?\u003c\/p\u003e\n\u003cp\u003eDisconnect analog loop power before unplugging the cable to prevent signal disruption to active loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat measures prevent signal cross-talk across adjacent analog channels?\u003c\/p\u003e\n\u003cp\u003eIndividually twisted conductor pairs with overall foil and braid shielding suppress channel cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021109088429,"sku":"NKAS01-9","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-nktu01-20-bailey-infi-90-termination-unit-cable-thpcndfjftc.jpg?v=1766983401","url":"https:\/\/www.maxwellplc.com\/ru\/products\/abb-nkas01-9-bailey-infi-90-analog-module-termination-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}