{"product_id":"abb-gjr2326500r1010-88vu01a-analog-output-module-ac-800pec","title":"ABB GJR2326500R1010 88VU01A Analog Output Module AC 800PEC","description":"\u003cp\u003eThe \u003cstrong\u003eABB GJR2326500R1010 88VU01A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eGJR2326500R1010\u003c\/strong\u003e Analog Output Module, operates as a dedicated hardware component for multi-channel analog signal generation within AC 800PEC control networks.\u003c\/p\u003e\n\u003ch3\u003eTechnical Identifier Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model:\u003c\/strong\u003e GJR2326500R1010\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardware Variant:\u003c\/strong\u003e 88VU01A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries Name:\u003c\/strong\u003e AC 800PEC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Analog Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarmonized Tariff Code:\u003c\/strong\u003e 8537101190\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGJR2326500R1010 88VU01A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.75 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4.0 cm x 25.8 cm x 26.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e4.0 cm x 25.8 cm x 26.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C ... +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003eCurrent source 0-20 mA or 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1 % of full scale @ 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Capability\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 550 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 VDC channel-to-bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C ... +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Controller Processing \u0026amp; Backplane Communication\u003c\/h3\u003e\n\u003cp\u003eThe GJR2326500R1010 88VU01A interfaces directly with the AC 800PEC system backplane to convert digital processing commands into high-density 16-bit analog output signals. Operating across 8 independent channels configured for current source outputs of 0-20 mA or 4-20 mA, the module processes loop commands with a full-scale accuracy of +\/-0.1 % at 25 deg C. Integrated 500 VDC channel-to-bus galvanic isolation protects backplane bus velocity and controller firmware processing logic against field loop transients, maintaining signal determinism across inductive load impedances up to 550 ohm.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents \u0026amp; Ordering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x ABB GJR2326500R1010 88VU01A Analog Output Module\u003c\/li\u003e\n\u003cli\u003e1x Factory Hardware Datasheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the module into the designated AC 800PEC subrack slot, ensuring structural guide rails line up with backplane connectors before fully seating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect field loops using twisted-pair conductors to output terminals for current source loops (0-20 mA \/ 4-20 mA) powered by the 24 VDC supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Terminate field analog signal cables with continuous 360-deg braid shielding at the cabinet grounding bar to eliminate common-mode noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect subrack frame protective ground points directly to the main protective earth (PE) bus using low-impedance copper conductors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal output formats are supported by the GJR2326500R1010 88VU01A?\u003c\/p\u003e\n\u003cp\u003eThe module provides 8 independent channels supporting user-configurable current source outputs of 0-20 mA or 4-20 mA.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat digital-to-analog conversion resolution does the module execute?\u003c\/p\u003e\n\u003cp\u003eSignal processing logic executes digital-to-analog conversion at 16-bit resolution across all 8 channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum load resistance allowable per channel?\u003c\/p\u003e\n\u003cp\u003eEach analog output channel supports driving inductive and resistive loop loads rated up to \u0026lt;= 550 ohm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat isolation voltage exists between the field channels and the system backplane?\u003c\/p\u003e\n\u003cp\u003eThe hardware features a channel-to-bus galvanic isolation rating of 500 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical envelope dimensions apply to the GJR2326500R1010 88VU01A?\u003c\/p\u003e\n\u003cp\u003eThe physical module dimensions measure exactly 4.0 cm x 25.8 cm x 26.1 cm with a total weight of 0.75 kg.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the operating temperature range for the hardware?\u003c\/p\u003e\n\u003cp\u003eThe module is rated for continuous industrial operation across an ambient temperature range of -20 deg C ... +70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage is required to power the analog output circuitry?\u003c\/p\u003e\n\u003cp\u003eThe module requires an external auxiliary power supply input rated at 24 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output accuracy can be expected under nominal operating conditions?\u003c\/p\u003e\n\u003cp\u003eThe output channel conversion accuracy is certified at +\/-0.1 % of full scale at an ambient baseline of 25 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021044404397,"sku":"GJR2326500R1010","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/GJR2326500R1010_2.jpg?v=1788241146","url":"https:\/\/www.maxwellplc.com\/ru\/products\/abb-gjr2326500r1010-88vu01a-analog-output-module-ac-800pec","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}