{"product_id":"abb-di810-3bse008508r1-digital-input-module-16-channels-for-s800-i-o","title":"ABB DI810 3BSE008508R1 Digital Input Module 16 Channels for S800 I\/O","description":"\u003cp\u003eConfigured for digital signal acquisition in S800 I\/O distributed control architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB DI810\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3BSE008508R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Input Module) provides direct physical electrical execution. The module manages 16 input channels partitioned into two isolated groups, processing 24 VDC field signals while utilizing integrated voltage supervision and optical isolation to maintain signal integrity within high-interference industrial environments.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFull Model: DI810 3BSE008508R1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBase Model: DI810\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHardware Type: Digital Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDI810 3BSE008508R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.5 x 10.5 x 12 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18–30 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Bus Performance\u003c\/h3\u003e\n\u003cp\u003eThe DI810 module maintains deterministic backplane bus communication velocity via the ABB ModuleBus, ensuring real-time diagnostic reporting and status updates. Firmware flash compatibility allows the module to align with evolving system control software, while IO density scaling is optimized to support high-channel-count cabinet configurations. The integrated circuitry provides active current limiting and EMC suppression, ensuring that backplane communication remains stable even during transient voltage fluctuations on the field-side loop.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSingle DI810 3BSE008508R1 digital input module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation for S800 I\/O installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial protective packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Secure the module to the designated MTU (Module Termination Unit) on a standard DIN-rail. Ensure the ModuleBus connector is firmly locked.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Terminate cable shields at the module or cabinet grounding rail to maintain EMC protection levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring: Ensure field wiring is rated for 24 VDC operation and verify polarity before energizing the loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics: Verify individual channel status via front-mounted LEDs to confirm proper signal transmission during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eThe S800 I\/O system supports hot-swapping. Refer to the system hardware manual for specific procedures to avoid triggering process alarms during replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the module isolated?\u003c\/p\u003e\n\u003cp\u003eThe module features optical isolation between the field inputs and the system bus, plus independent isolation for the two input groups.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the field supply voltage drops?\u003c\/p\u003e\n\u003cp\u003eThe module includes integrated voltage supervision; it will detect a loss of supply voltage and report the fault condition via the ModuleBus to the controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the DI810 be used for safety functions?\u003c\/p\u003e\n\u003cp\u003eThe DI810 is a standard process I\/O module. Consult local safety integrity specifications before using it for critical safety interlock applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the input voltage range configurable?\u003c\/p\u003e\n\u003cp\u003eThe input range is fixed for 24 VDC nominal signals; refer to the datasheet for specific ON\/OFF threshold limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the current draw per channel?\u003c\/p\u003e\n\u003cp\u003eThe module draws approximately 6 mA per channel at 24 VDC nominal input voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is fault detection executed?\u003c\/p\u003e\n\u003cp\u003eFaults are communicated automatically to the central controller through the ModuleBus interface for rapid localization by engineering staff.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module require periodic calibration?\u003c\/p\u003e\n\u003cp\u003eThe digital input circuit is solid-state and does not require field calibration; however, periodic visual inspection of wiring and terminals is recommended.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231189557421,"sku":"3BSE008508R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-di810-3bse008508r1-digital-input-module-c5hpwxkxfr4_3e7d4256-2502-4df3-8fc4-21b4b0af77ab.jpg?v=1762942412","url":"https:\/\/www.maxwellplc.com\/ru\/products\/abb-di810-3bse008508r1-digital-input-module-16-channels-for-s800-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}