{"product_id":"abb-ci820v1-3bse025255r1-communication-interface-modules-s800","title":"ABB CI820V1 3BSE025255R1 Communication Interface Modules S800","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCI820V1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3BSE025255R1\u003c\/strong\u003e)\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCommunication Interface Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCI820V1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCommunication Interface Module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eused to execute control or monitoring functions across automation platforms. This hardware component functions as a redundant Field Communication Interface (FCI) specifically designed for integration with the ABB S800 I\/O system within Distributed Control System (DCS) architectures. It manages deterministic data exchange between the central controller and remote I\/O nodes, providing a resilient communication path that ensures operational continuity even in the event of a single-path network fault.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCI820V1 (3BSE025255R1)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.48 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17 x 5.6 x 12 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndustrial Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane Bus Powered\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 kbit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEthernet Router \/ FCI\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS800 I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBrand-Specific Technical Block\u003c\/h3\u003e\n\u003cp\u003eThe CI820V1 utilizes the ABB S800 I\/O backplane communication protocol to ensure deterministic timing for I\/O data updates. The module facilitates seamless integration with the controller's I\/O configuration, supporting both redundant and non-redundant operational modes. It is engineered to maintain firmware compatibility with existing S800 I\/O modules, allowing for scalable I\/O density within a single rack assembly. Integrated error-checking routines handle frame synchronization across the network, while the module's bus communication velocity is optimized to minimize latency during high-traffic cycles in complex process control loops.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIncluded items: Communication Interface Module, mounting base connectors, dust covers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard package: Industrial anti-static sealed enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional accessories: Spare bus termination units, shielded communication patch cables, redundant cable routing guides.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the mounting rack base is properly secured to the cabinet frame, maintaining alignment with the S800 I\/O bus connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the CI820V1 in a designated redundant-capable slot; ensure the mechanical locking latches are fully engaged to secure the module to the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround the rack base assembly to the main cabinet common earth point to mitigate electromagnetic interference (EMI) on the fieldbus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded, twisted-pair cabling for fieldbus connections, ensuring the shield is terminated according to the S800 system grounding guidelines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain a minimum clearance of 5 cm above and below the module to allow for natural convection cooling within the cabinet environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvoid exposing the backplane connectors to metallic debris or dust during module insertion to prevent contact arcing or signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CI820V1 support hot-swap behavior?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for hot-swap operations within an active S800 I\/O rack, provided the system controller software is configured to handle the transient state.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit impact backplane load?\u003c\/p\u003e\n\u003cp\u003eA: The CI820V1 draws its operational power from the backplane; total system power calculations must account for the specific current draw of the module in a redundant setup.\u003c\/p\u003e\n\u003cp\u003eQ: What is the redundancy switching delay?\u003c\/p\u003e\n\u003cp\u003eA: Redundancy switching is dictated by the controller logic and communication timeout settings, typically occurring within a few milliseconds during a path failure.\u003c\/p\u003e\n\u003cp\u003eQ: Is firmware compatibility required?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the CI820V1 firmware must match the version requirements set by the controller's configuration file in the ABB Control Builder system.\u003c\/p\u003e\n\u003cp\u003eQ: Does the unit provide signal isolation?\u003c\/p\u003e\n\u003cp\u003eA: The communication interface includes galvanic isolation to decouple the controller backplane from the fieldbus physical layer.\u003c\/p\u003e\n\u003cp\u003eQ: What are the field wiring constraints?\u003c\/p\u003e\n\u003cp\u003eA: Wiring must adhere to the 1500 kbit\/s bandwidth specifications; exceeding recommended segment lengths can lead to signal reflections and data loss.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module operate in non-redundant configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, it is fully functional as a single-path communication interface if redundancy is not required by the process architecture.\u003c\/p\u003e\n\u003cp\u003eQ: How can diagnostic faults be monitored?\u003c\/p\u003e\n\u003cp\u003eA: Diagnostic status is mapped directly to the controller's status registers, accessible via the system diagnostic software and engineering workstations.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231184773293,"sku":"3BSE025255R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-ci820v1-3bse025255r1-redundant-fci-tx4ix5ptaw4_b6087492-440e-49d9-aea5-dbdf99277f8d.jpg?v=1762942375","url":"https:\/\/www.maxwellplc.com\/ru\/products\/abb-ci820v1-3bse025255r1-communication-interface-modules-s800","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}