{"product_id":"abb-87ts50e-e-gkwe857800r1214-transformer-protection-coupling-module-procontrol-p13-p14","title":"ABB 87TS50E-E GKWE857800R1214 Transformer Protection Coupling Module Procontrol P13\/P14","description":"\u003cp\u003eConfigured for differential transformer protection in Procontrol P13\/P14 and 800xA distributed control architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB 87TS50E-E\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eGKWE857800R1214\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTransformer Protection Coupling Module) provides direct physical electrical execution. The module monitors three-phase current inputs to execute rapid fault detection and network synchronization tasks across high-voltage infrastructure.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFull Model: 87TS50E-E GKWE857800R1214\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBase Model: 87TS50E-E\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHardware Type: Transformer Protection Coupling Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e87TS50E-E GKWE857800R1214\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.72 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 x 19.7 x 26.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 deg C to +55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFault Detection Speed\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 20 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMonitoring System\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree-phase current with harmonic restraint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61850\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Bus Performance\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes high-speed backplane bus communication velocity to maintain synchronization within Procontrol and 800xA environments. It supports firmware flash compatibility, allowing integration with modern digital substation communication frameworks. The internal I\/O density scaling is optimized to ensure that fault analysis and event logging do not induce latency in the primary protection trip path. This architecture allows the module to operate as a deterministic node within fiber-optic communication networks while maintaining compatibility with legacy control logic.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSingle 87TS50E-E GKWE857800R1214 protection module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard technical datasheet and safety certification documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective shipping container to prevent mechanical damage during transit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Secure the module chassis to the substation cabinet ground bus to ensure compliance with EMI\/EMC shielding requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOrientation: Install the module in a vertical orientation to facilitate passive convection cooling through the unit vents.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring: Ensure CT secondary connections are tightly secured to prevent high-voltage arcing during current measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics: Use the front-facing HMI for initial configuration and verification of communication handshake before placing the unit in service.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the typical fault detection response time?\u003c\/p\u003e\n\u003cp\u003eThe internal protection logic typically executes in less than 20 ms to isolate the primary transformer from grid faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is false tripping prevented during transformer startup?\u003c\/p\u003e\n\u003cp\u003eThe module incorporates an adaptive harmonic restraint function to distinguish between magnetizing inrush currents and actual internal faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the device compatible with non-ABB SCADA frameworks?\u003c\/p\u003e\n\u003cp\u003eYes, the native support for the IEC 61850 communication protocol enables integration into multivendor digital substation systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan event logs be retrieved locally?\u003c\/p\u003e\n\u003cp\u003eYes, the integrated front-facing HMI provides access to detailed event logs and historical disturbance recording data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary environmental rating for the unit?\u003c\/p\u003e\n\u003cp\u003eThe module is categorized as substation grade, operating reliably within a temperature range of -25 deg C to +55 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module require external communication converters?\u003c\/p\u003e\n\u003cp\u003eNo, it features native IEC 61850 connectivity for direct bridging to modern fiber-optic network infrastructures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the module field-repairable?\u003c\/p\u003e\n\u003cp\u003eThe 87TS50E-E is a sealed industrial protection module intended for unit-level replacement; field-level repairs of the protection logic are not supported.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does this unit differ from standard analog I\/O?\u003c\/p\u003e\n\u003cp\u003eUnlike standard I\/O, this module contains dedicated multi-criteria logic for transformer protection, including current measurement and differential tripping algorithms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231191294125,"sku":"GKWE857800R1214","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-87ts50e-e-gkwe857800r1214-procontrol-system-coupling-module-r305xayey4o_17b7de3f-1284-49f4-a6ed-4bc3e5354086.jpg?v=1762942425","url":"https:\/\/www.maxwellplc.com\/ru\/products\/abb-87ts50e-e-gkwe857800r1214-transformer-protection-coupling-module-procontrol-p13-p14","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}