{"product_id":"abb-3hac047574-002-irc5-series-ac-motor","title":"ABB 3HAC047574-002 IRC5 Series AC Motor","description":"\u003cp\u003eThe \u003cstrong\u003eABB 3HAC047574-002\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e3HAC047574\u003c\/strong\u003e AC motor, operates as a dedicated hardware component for electromechanical rotational drive actuation within ABB IRC5 motion system networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Designation Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3HAC047574-002:\u003c\/strong\u003e Standard production 132 mm frame AC motor assembly supplied for high-torque industrial drive applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3HAC047574:\u003c\/strong\u003e Base electromechanical stator-rotor housing unit configured for 3-phase AC voltage inputs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3HAC047574-002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003e132 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\u003c\/td\u003e\n\u003ctd\u003e18.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Speed\u003c\/td\u003e\n\u003ctd\u003e1500 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e400 V (3-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current\u003c\/td\u003e\n\u003ctd\u003e35.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Frequency\u003c\/td\u003e\n\u003ctd\u003e50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e18.5 kW nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e32.9 x 20.3 x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Drive Architecture\u003c\/h3\u003e\n\u003cp\u003eThis AC motor unit operates via variable frequency drive amplifiers interconnected through Profinet and EtherNet\/IP deterministic networks. High-speed feedback synchronization relies on firmware flash compatibility between host controller parameters and motor feedback electronics, ensuring low-latency loop response and optimized I\/O density scaling during load variation.\u003c\/p\u003e\n\u003ch3\u003eFulfillment Package Checklist\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB 3HAC047574-002 AC Motor unit\u003c\/li\u003e\n\u003cli\u003eFactory-installed terminal box sealing gaskets\u003c\/li\u003e\n\u003cli\u003eIndustrial protective packaging with shock-absorbing foam\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting and Wiring Protocol\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that all 3-phase power lines are completely isolated prior to landing conductors on the terminal block.\u003c\/li\u003e\n\u003cli\u003eEnsure precise angular and radial shaft alignment with the gear reducer to eliminate premature bearing failure.\u003c\/li\u003e\n\u003cli\u003eFasten mounting flange hardware diagonally using calibrated torque wrenches to maintain rigid alignment.\u003c\/li\u003e\n\u003cli\u003eRoute motor power conductors in grounded steel conduit isolated from parallel signal instrumentation lines.\u003c\/li\u003e\n\u003cli\u003eAttach a low-impedance copper ground wire from the motor frame terminal directly to primary system earth.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the rated full-load current draw for this motor?\u003c\/p\u003e\n\u003cp\u003eThe motor draws a rated current of 35.5 A when operating at full 18.5 kW load under a 400 V 3-phase supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat synchronous speed does the stator winding support at 50 Hz?\u003c\/p\u003e\n\u003cp\u003eThe electromagnetic design runs at a synchronous rated speed of 1500 RPM under a standard 50 Hz supply frequency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-plugging of the power wiring permitted during operation?\u003c\/p\u003e\n\u003cp\u003eHot-plugging is strictly prohibited. Disconnecting 400 V phase conductors under load creates electrical arcs and damages terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature limits govern standard motor operation?\u003c\/p\u003e\n\u003cp\u003eThe unit is engineered for continuous operation within ambient temperature limits of -20 deg C to +40 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should motor power wiring shields be terminated at the junction box?\u003c\/p\u003e\n\u003cp\u003eSecure cable shields using 360-degree metallic grounding clamps fastened directly to the metal terminal box wall.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical frame designation does this AC motor use?\u003c\/p\u003e\n\u003cp\u003eThe housing assembly adheres to the standardized 132 mm frame size specification for industrial motor mountings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat network standards coordinate drive pulses to this motor?\u003c\/p\u003e\n\u003cp\u003eDrive units commanding this motor communicate over Profinet or EtherNet\/IP deterministic networks for precise speed control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat torque precautions apply during mechanical shaft coupling setup?\u003c\/p\u003e\n\u003cp\u003eDo not apply axial impact forces to the shaft end; always use mechanical pullers and press tools for coupling fitment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021057577133,"sku":"3HAC047574-002","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3HAC021799-003-0_5a018c9c-bb5f-4e51-b5ed-614b64408228.jpg?v=1786614976","url":"https:\/\/www.maxwellplc.com\/ru\/products\/abb-3hac047574-002-irc5-series-ac-motor","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}