{"product_id":"abb-1mrk000167-gcr00-1mrk-series-circuit-card","title":"ABB 1MRK000167-GCr00 1MRK Series Circuit Card","description":"\u003cp\u003eConfigured for discrete digital signal acquisition and internal logic execution in protection and control racks, the \u003cstrong\u003eABB 1MRK000167-GCr00\u003c\/strong\u003e (\u003cstrong\u003e1MRK000167\u003c\/strong\u003e Circuit Card) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eComponent Designators \u0026amp; Spare Cross-Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1MRK000167-GCr00\u003c\/strong\u003e: Primary manufacturing catalog number and revision designator.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1MRK\u003c\/strong\u003e: Protection and control hardware family platform prefix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1MRK000005-258\u003c\/strong\u003e: Designated spare part cross-reference catalog code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1MRK000167-GCr00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSWEDEN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.32 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e23.3 cm x 17.0 cm x 1.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 to 250 VDC\/AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 to 10 W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e2 kV AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Structure\u003c\/td\u003e\n\u003ctd\u003e6-layer PCB design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital I\/O Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% RH (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSystem Backplane \u0026amp; Bus Isolation\u003c\/h3\u003e\n\u003cp\u003eThe circuit card integrates a multi-layer board topology to sustain high backplane bus communication velocity across adjacent protection processing units. Solid-state isolation barriers decouple internal logic from field transients, ensuring firmware flash compatibility and deterministic logic routing across I\/O expansion racks.\u003c\/p\u003e\n\u003ch3\u003eStandard Equipment Delivery\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x ABB 1MRK000167-GCr00 circuit card\u003c\/li\u003e\n\u003cli\u003e1 x Technical terminal mapping and installation document\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Assembly \u0026amp; Wiring Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRack Insertion\u003c\/p\u003e\n\u003cp\u003eAlign the 6-layer board edges carefully with card guide rails and seat the rear connector firmly into the backplane bus socket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing\u003c\/p\u003e\n\u003cp\u003eSeparate 24 VDC digital I\/O lines from high-voltage AC control circuits in panel channels to prevent EMI coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEarthing Connections\u003c\/p\u003e\n\u003cp\u003eMaintain rigid metal-to-metal grounding contact between the card front panel plate and the subrack chassis frame.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat operating voltage range is supported by the 1MRK000167-GCr00 circuit card?\u003c\/p\u003e\n\u003cp\u003eThe card circuitry accommodates wide auxiliary operating supplies ranging from 24 to 250 VDC\/AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the typical power consumption of this module under load?\u003c\/p\u003e\n\u003cp\u003ePower consumption for the assembly typically ranges between 5 W and 10 W depending on active I\/O switching states.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat galvanic isolation rating applies to field input terminals?\u003c\/p\u003e\n\u003cp\u003eThe board incorporates optical and physical isolation barriers rated up to 2 kV AC between logic and field circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping permitted for this circuit card inside a energized rack?\u003c\/p\u003e\n\u003cp\u003eNo, power to the rack chassis must be isolated prior to removing or installing the circuit card assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the rated operating temperature range for field deployment?\u003c\/p\u003e\n\u003cp\u003eThe hardware is rated for continuous operation across temperature extremes from -40 deg C to +70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat PCB manufacturing standard is utilized for this module?\u003c\/p\u003e\n\u003cp\u003eThe assembly is built using a high-density 6-layer printed circuit board design with internal ground and power planes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are digital I\/O channels rated on the terminal interface?\u003c\/p\u003e\n\u003cp\u003eThe digital input and output interface operates at a nominal rated logic potential of 24 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat spare part model replaces the 1MRK000167-GCr00 assembly?\u003c\/p\u003e\n\u003cp\u003eThe manufacturer cross-references spare model catalog number 1MRK000005-258 for field hardware replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021058461869,"sku":"1MRK000167-GCr00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_1mrk000167-gcr00_3.jpg?v=1787892127","url":"https:\/\/www.maxwellplc.com\/ru\/products\/abb-1mrk000167-gcr00-1mrk-series-circuit-card","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}