{"product_id":"990-10-xx-01-05-mod-165353-07-bently-nevada-990-series-vibration-transmitter","title":"990-10-XX-01-05 MOD:165353-07 Bently Nevada 990 Series Vibration Transmitter","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 990-10-XX-01-05 MOD:165353-07\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e990\u003c\/strong\u003e Vibration Transmitter, operates as a dedicated hardware component for vibration signal conditioning and displacement monitoring within Bently Nevada machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Details\u003c\/h3\u003e\n\u003cp\u003eThe 990-10-XX-01-05 MOD:165353-07 is a 990 Series vibration transmitter configured with a 0-10 mils peak-to-peak measurement range, selectable 5.0 meter and 7.0 meter system length options, 35 mm DIN rail mounting, and hazardous area approval configuration.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003eFull-scale range: 0-10 mils pp (0-250 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eXX\u003c\/td\u003e\n\u003ctd\u003eSystem length option: 5.0 meters (16.4 feet) or 7.0 meters (23.0 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e01\u003c\/td\u003e\n\u003ctd\u003eMounting option: 35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e05\u003c\/td\u003e\n\u003ctd\u003eApproval option: CSA Division 2, ATEX Zone 0, ATEX Zone 2, ABS maritime approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-10-XX-01-05 MOD:165353-07\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVibration Transmitter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e990 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e10 x 7.3 x 5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +85 deg C (-31 deg F to +185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-52 deg C to +100 deg C (-62 deg F to +212 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRequires +12 to +35 VDC input at transmitter terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-scale Range\u003c\/td\u003e\n\u003ctd\u003e0-10 mils pp (0-250 um pp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e5 Hz to 6,000 Hz, +0, -3 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Loop Resistance\u003c\/td\u003e\n\u003ctd\u003e1,000 ohms including cable at 35 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Limiting\u003c\/td\u003e\n\u003ctd\u003e23 mA typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail clips\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Rating\u003c\/td\u003e\n\u003ctd\u003eCSA Division 2, ATEX Zone 0, ATEX Zone 2, ABS maritime approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Signal Processing Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 990 Series transmitter receives vibration signals from compatible eddy-current proximity probe systems and converts displacement measurements into conditioned electrical outputs. The configured scaling range determines the relationship between probe input displacement and transmitter output response.\u003c\/p\u003e\n\u003cp\u003eEddy-current probe scaling verification is required during installation to ensure correct vibration amplitude conversion. Gap voltage validation, including the typical -10 VDC probe gap target, should be checked according to the connected proximity monitoring system requirements.\u003c\/p\u003e\n\u003ch3\u003eRotor Dynamics Monitoring Interface\u003c\/h3\u003e\n\u003cp\u003eThe 990-10-XX-01-05 MOD:165353-07 provides signal conditioning for rotating machinery vibration measurement circuits. The 5 Hz to 6,000 Hz frequency response range supports vibration signal transmission across a broad machinery operating spectrum.\u003c\/p\u003e\n\u003cp\u003eProper cable routing is required to reduce electrical interference and cross-talk. Signal grounding and shield termination practices should follow the installation requirements of the associated Bently Nevada monitoring equipment.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 990-10-XX-01-05 MOD:165353-07 Vibration Transmitter\u003c\/li\u003e\n\u003cli\u003e1 x 990 Series transmitter electronics assembly\u003c\/li\u003e\n\u003cli\u003e1 x 35 mm DIN rail mounting clip assembly\u003c\/li\u003e\n\u003cli\u003e1 x Configured hazardous area approval option set\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Mounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the transmitter on a compatible 35 mm DIN rail.\u003c\/li\u003e\n\u003cli\u003eConfirm the installation location matches the specified hazardous area classification.\u003c\/li\u003e\n\u003cli\u003eProvide sufficient access for terminal wiring and inspection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Installation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect a +12 to +35 VDC supply at the transmitter terminal.\u003c\/li\u003e\n\u003cli\u003eEnsure total loop resistance remains within the specified 1,000 ohm limit including cable resistance.\u003c\/li\u003e\n\u003cli\u003eSeparate vibration signal wiring from high-current power cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Verification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm probe scaling before commissioning.\u003c\/li\u003e\n\u003cli\u003eVerify vibration output response against expected displacement input.\u003c\/li\u003e\n\u003cli\u003eCheck shielding and grounding connections to minimize signal interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat vibration range does the 990-10-XX-01-05 support?\u003c\/p\u003e\n\u003cp\u003eThis configuration supports a 0-10 mils peak-to-peak measurement range, equivalent to 0-250 um peak-to-peak displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the operating temperature range?\u003c\/p\u003e\n\u003cp\u003eThe transmitter operates from -35 deg C to +85 deg C and can be stored from -52 deg C to +100 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat power supply voltage is required?\u003c\/p\u003e\n\u003cp\u003eThe unit requires a +12 to +35 VDC input supply connected directly at the transmitter terminal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the frequency response range?\u003c\/p\u003e\n\u003cp\u003eThe transmitter provides a frequency response from 5 Hz to 6,000 Hz with +0 and -3 dB limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mounting method is included?\u003c\/p\u003e\n\u003cp\u003eThe configured model includes 35 mm DIN rail clips for panel mounting installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat hazardous approvals are included?\u003c\/p\u003e\n\u003cp\u003eThis configuration includes CSA Division 2, ATEX Zone 0, ATEX Zone 2 and ABS maritime approval options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum loop resistance?\u003c\/p\u003e\n\u003cp\u003eThe maximum loop resistance is 1,000 ohms including cable resistance when operating at 35 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the transmitter require probe calibration?\u003c\/p\u003e\n\u003cp\u003eProbe scaling and gap voltage verification should be completed to match the connected eddy-current measurement system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026537894061,"sku":"990-10-XX-01-05 165353-07","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/990-10-xx-01-05.jpg?v=1785736853","url":"https:\/\/www.maxwellplc.com\/ru\/products\/990-10-xx-01-05-mod-165353-07-bently-nevada-990-series-vibration-transmitter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}