{"product_id":"89477-30-bently-nevada-interconnect-cables-3500-series","title":"89477-30 Bently Nevada Interconnect Cables 3500 Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 89477-30\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e89477\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInterconnect Cables, operates as a dedicated hardware component for signal transmission between monitoring modules and I\/O modules within 3500 Machinery Protection System networks.\u003c\/p\u003e\n\u003ch3\u003eInterface Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 89477-30 provides a standardized physical connection path for rack-based instrumentation. This interconnect assembly ensures the electrical continuity of low-level signals traveling from the rack backplane to the external termination interfaces. It is designed for integration into 3500 series racks to facilitate communication between internal monitoring cards and field-side wiring terminals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e89477-30\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.0 * 20.0 * 5.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-conductor shielded\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRack-interface keyed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSignal Integrity and Cross-talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe interconnect cable maintains signal fidelity by minimizing electromagnetic interference during data transmission from the sensor interface modules to the rack termination boards. Proper routing within the rack enclosure is required to prevent coupling with high-voltage power distribution. The internal shielding reduces susceptibility to external radio frequency interference, ensuring that the raw eddy-current probe signals remain within specified noise thresholds for accurate rotor dynamics interpretation. Shield continuity must be verified to prevent ground loops across the rack termination interfaces.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 89477-30 Interconnect Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated rack-interface connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTermination housing clips\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRouting:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall cables within the internal cable management channels of the 3500 rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain minimum separation from power supply input leads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eTermination:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that the rack interface connector is fully seated to prevent intermittent signal loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the connector keying aligns with the I\/O module socket before applying pressure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eInspection:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCheck for physical damage to the outer jacket during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerform a loop continuity test to verify signal integrity before initializing the monitoring system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be extended in the field?\u003c\/p\u003e\n\u003cp\u003eNo. Modification of the cable assembly changes the electrical characteristics and impedance, leading to signal degradation and potential monitoring system errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 89477-30 compatible with legacy 3300 series racks?\u003c\/p\u003e\n\u003cp\u003eNo. This cable is engineered specifically for the pin-out and interface geometry of the 3500 series machinery protection system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signal types does this cable carry?\u003c\/p\u003e\n\u003cp\u003eIt transmits transducer data, power supply feedback, and digital communication signals between the rack backplane and the I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the cable shielded from noise?\u003c\/p\u003e\n\u003cp\u003eThe cable utilizes a multi-conductor shield design that bonds to the rack chassis ground to drain induced electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the connector hot-swappable?\u003c\/p\u003e\n\u003cp\u003eThe 3500 system modules support hot-swapping, but the interconnect cables should be handled with care while the rack is powered to avoid short-circuiting signal pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the recommended bend radius for this cable?\u003c\/p\u003e\n\u003cp\u003eTo prevent mechanical fatigue on the conductors, maintain a bend radius of at least 50 mm during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this cable require any firmware configuration?\u003c\/p\u003e\n\u003cp\u003eNo. This is a passive hardware component and does not contain logic or require firmware updates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow can a faulty cable be identified?\u003c\/p\u003e\n\u003cp\u003eA faulty cable typically manifests as module communication errors or erratic sensor readings on the 3500 TDI interface or monitoring rack status.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518838431917,"sku":"89477-30","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-89477-30-interconnect-cable-2ghiozj2yov.jpg?v=1766980124","url":"https:\/\/www.maxwellplc.com\/ru\/products\/89477-30-bently-nevada-interconnect-cables-3500-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}